Inspection 341806198 OPENED SEP 29, 2016Closed
5035 Route 60, Sinclairville, NY 14782 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Sinclairville, New York · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · NAICS 333514
Spartan Tool & Die has 3 OSHA inspections on record in New York, the first in 2016.
OSHA's last visit started on Sep 29, 2016 to follow up on an earlier case, in Sinclairville.
Across those inspections OSHA issued 18 citation items: 15 serious and 3 other-than-serious.
OSHA proposed $54,000 in penalties. After settlements and reviews the total is $32,400, down 40%.
Most often, OSHA cited 1910.217, mechanical power presses (4 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Spartan Tool & Die averages $32,400 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
361employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Spartan Tool & Die and get notified the morning OSHA posts a new citation for it.
Watch this company5035 Route 60, Sinclairville, NY 14782 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5035 Route 60, Sinclairville, NY 14782 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5035 Route 60, Sinclairville, NY 14782 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(6)(i)(c) · Lockout/tagout |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 5a 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $3,600 | $2,160 | Jul 26, 2016 | Final |
| Citation 1, item 5b 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 1, item 5c 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 7a 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 7b 29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks |
Serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 1, item 8 29 CFR 1910.184(i)(9)(iii) · Slings |
Serious | $3,600 | $2,160 | Jul 26, 2016 | Final |
| Citation 1, item 9 29 CFR 1910.217(b)(4)(i) · Mechanical power presses |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 10 29 CFR 1910.217(b)(4)(ii) · Mechanical power presses |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 1, item 11 29 CFR 1910.217(c)(1)(i) · Mechanical power presses |
Serious | $6,300 | $3,780 | Jul 26, 2016 | Final |
| Citation 1, item 12 29 CFR 1910.217(e)(1)(i) · Mechanical power presses |
Serious | $4,500 | $2,700 | Jul 26, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.37(b)(5) · Exit routes |
Other-than-serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Jul 26, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.147(c)(4)(ii)(c) · Lockout/tagout |
Other-than-serious | $0 | $0 | Jul 26, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(4)(ii)(c)
(C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.