Spinweld, Inc.: OSHA inspections and violations

Waukesha, Wisconsin · Fluid Power Valve and Hose Fitting Manufacturing · NAICS 332912

7inspections
27citation items
$35,310current penalties
Apr 11, 2019last inspection

Since 2012, OSHA inspectors have visited Spinweld, Inc. in Wisconsin 7 times.

The most recent inspection opened on Apr 11, 2019 after a complaint, in Waukesha.

In all, OSHA issued 27 citation items: 24 serious, 1 repeat and 2 other-than-serious.

The proposed penalties came to $74,645; today they stand at $35,310, 53% less.

The rule cited most here is 1910.212 (machine guarding), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Spinweld, Inc. averages $8,302 across 4 cited inspections.

It reported 2 severe injuries to OSHA since 2015.

Spinweld, Inc.: OSHA citation items per year, 2012 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Spinweld, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343923710 OPENED APR 11, 2019Closed

Complaint · Partial · Health · 20 employees at the site · Closed Dec 1, 2021

W227 N546 Westmound Road, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h) · Hazard communication
Serious$10,002$2,280Sep 27, 2019Final

Inspection 343924973 OPENED APR 11, 2019Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Dec 13, 2021

W227 N546 Westmound Road, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$4,168$1,500Sep 10, 2019Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$4,168$1,500Sep 10, 2019Final
Citation 1, item 3a
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,501$1,500Sep 10, 2019Final
Citation 1, item 3b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$2,501$0Sep 10, 2019Final
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$11,669$5,240Sep 10, 2019Final

Inspection 343393922 OPENED AUG 15, 2018Closed

Referral · Partial · Health · 12 employees at the site · Closed Nov 5, 2021

W227 N546 Westmound Road, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Aug 15, 2018: Twelve employees experience carbon monoxide exposure from pi

On August 15, 2018, at least thirteen employees were working for a manufacturer of fluid power valve and hose fittings. One employee was operating a Toyota model number 5FGC25 forklift, with serial number 12326, to arrange stock for production. It was in use in the shipping and receiving area of the main production floor for performing normal operational duties during the morning hours. Employees on the main production floor began to have significant headache symptoms, prompting employers to contact the natural gas supplier for the worksite. First responders arrived on the scene at approximately 12:45 (either a.m. or p.m.). Twelve employees were treated for elevated carboxyhemoglobin levels. Eight employees were transported to Waukesha Memorial Hospital by ambulance due to significantly elevated carboxyhemoglobin levels caused by carbon monoxide emitted from the forklift. Four other employees went to the hospital for monitoring due to slightly elevated carboxyhemoglobin levels. Treated employees included men and women, aged 21 to 58 years old. All employees recovered fully from the carbon monoxide exposure with treatment. In all, twelve employees were hospitalized. A thirteenth employee was not hospitalized. The faulty forklift was later repaired and returned to service. repaired and returned to service.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$5,304$3,400Feb 6, 2019Final
Citation 1, item 2a
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$5,304$3,400Feb 6, 2019Final
Citation 1, item 2b
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$0$0Feb 6, 2019Final
Citation 1, item 2c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Feb 6, 2019Final
Citation 1, item 3a
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$2,273$1,400Feb 6, 2019Final
Citation 1, item 3b Serious$0$0Feb 6, 2019Final
Citation 1, item 3c
29 CFR 1910.1018(e)(2) · Inorganic arsenic
Serious$0$0Feb 6, 2019Final
Citation 1, item 4a
29 CFR 1910.1025(l)(1)(ii) · Lead in general industry
Serious$2,273$1,400Feb 6, 2019Final
Citation 1, item 4b Serious$0$0Feb 6, 2019Final
Citation 1, item 4c
29 CFR 1910.1018(p)(1)(ii) · Inorganic arsenic
Serious$0$0Feb 6, 2019Final
Citation 2, item 1
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Feb 6, 2019Final

Inspection 341945491 OPENED DEC 1, 2016Closed

Referral · Partial · Safety · 13 employees at the site · Closed Feb 27, 2019

W227 N546 Westmound Drive, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,622$2,898Mar 3, 2017Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,622$0Mar 3, 2017Final
Citation 1, item 3
29 CFR 1910.178(m)(5)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$2,173$0Mar 3, 2017Final
Citation 1, item 4a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,070$4,056Mar 3, 2017Final
Citation 1, item 4b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0Mar 3, 2017Final
Citation 1, item 5a
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Serious$3,622$2,898Mar 3, 2017Final
Citation 1, item 5b
29 CFR 1910.1030(g)(2)(i) · Bloodborne pathogens
Serious$0$0Mar 3, 2017Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,173$1,738Mar 3, 2017Final
Citation 1, item 6b
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$0$0Mar 3, 2017Final

Inspection 340114180 OPENED DEC 3, 2014Closed

Complaint · Partial · Safety · 16 employees at the site · Closed May 28, 2015

W227 N546 Westmound Road, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339908543 OPENED AUG 19, 2014Closed

Complaint · Partial · Safety · 16 employees at the site · Closed Nov 5, 2014

W227 N546 Westmound Road, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 331899724 OPENED JAN 24, 2012Closed

Referral · Partial · Safety · 14 employees at the site · Closed May 15, 2012

W227 N546 Westmound Road, Waukesha, WI 53186 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 17, 2012: Employee lacerates and fractures hand when reaching into saw

At 8:45 a.m. on January 17, 2012, Employee #1 was operating a Kasto (HBA 360AU) CNC Saw to cut a 2-inch round steel stock. Employee #1 reached into the machine to move a piece of metal stock, when the clamp on the machine closed, injuring Employee #1 left hand. Employee #1 was hospitalized and suffered lacerations and fractures to his left hand.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,200$2,100Feb 9, 2012Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Aug 21, 2018, Waukesha: Hospitalization · cuts, lacerations · finger(s), fingernail(s), unspecified

An employee was trying to retrieve a part that was not loaded correctly in a machine when his finger was pinched and lacerated between the part and a component of the machine.

Nov 2, 2016, Waukesha: Hospitalization · fractures · finger(s), fingernail(s), unspecified

An employee was operating a friction welding unit when the clamp for hold-down caught and fractured the employee's left middle finger.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.1018 · Inorganic arsenic

29 CFR 1910.1018(e)(2)

(2) Initial monitoring. Each employer who has a workplace or work operation covered by this standard shall monitor each such workplace and work operation to accurately determine the airborne concentration of inorganic arsenic to which employees may be exposed.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1027 · Cadmium

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.334 · Using electrical equipment

Other fluid power valve and hose fitting manufacturing employers in Wisconsin