SPX Heat Transfer Inc.: OSHA inspections and violations
Tulsa, Oklahoma · Power Boiler and Heat Exchanger Manufacturing · NAICS 332410
2inspections
10citation items
$15,710current penalties
Aug 24, 2016last inspection
Since 2011, OSHA inspectors have visited SPX Heat Transfer Inc. in Oklahoma 2 times.
The most recent inspection opened on Aug 24, 2016 as a planned inspection, in Tulsa.
In all, OSHA issued 10 citation items: 9 serious and 1 other-than-serious.
The proposed penalties came to $29,300; today they stand at $15,710, 46% less.
The rule cited most here is 1910.215 (grinders and abrasive wheels), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. SPX Heat Transfer Inc. averages $6,360 across 1 cited inspection.
SPX Heat Transfer Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Oklahoma · latest 90 days of OSHA records
52employers cited
Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Tulsa site logged 0 recordable injuries or illnesses among about 11 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
SPX Heat Transfer LLC
Tulsa · 2019
11
0
0
0.0
2.8
Included with any plan: 2 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
(7) For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm.
Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.