Houston, Texas · Plastics Packaging Film and Sheet (including Laminated) Manufacturing · NAICS 326112
3inspections
5citation items
$21,925current penalties
Dec 5, 2022last inspection
OSHA has inspected Starpak LLC 3 times in Texas since 2010.
The latest one began on Dec 5, 2022 on a referral, in Houston.
Those inspections ended with 5 citation items: 2 serious and 3 other-than-serious.
Penalties were first proposed at $28,225 and now stand at $21,925, 22% lower after settlements or reviews.
Working near live electrical parts comes up most often in these citations: 2 items under 1910.333.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Starpak LLC averages $15,625 (1 cited inspection).
Starpak LLC also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
393employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Houston site logged 6 recordable injuries or illnesses among about 446 workers: 1.0 per 100 full-time workers, against a median of 2.6 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
StarPak LLC
Houston · 2024
446
6
0
1.0
2.6
Starpak, Corp.
Houston · 2022
500
11
2
1.9
2.6
Included with any plan: 4 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was clearing material from a dust collecting machine when their left hand was struck by the slide gate. They sustained a partial amputation of the left middle and index fingers.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(d)(3)
(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).
(2) Additional requirements for unqualified persons. Employees who are covered by paragraph (a) of this section but who are not qualified persons shall also be trained in and familiar with any electrically related safety practices not specifically addressed by §§ 1910.331 through 1910.335 but which are necessary for their safety.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.