Steel Tek: OSHA inspections and violations

Tulsa, Oklahoma · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

3inspections
14citation items
$10,200current penalties
Jan 25, 2017last inspection

Steel Tek has 3 OSHA inspections on record in Oklahoma, the first in 2010.

OSHA's last visit started on Jan 25, 2017 to follow up on an earlier case, in Tulsa.

Across those inspections OSHA issued 14 citation items: 12 serious and 2 other-than-serious.

OSHA proposed $17,080 in penalties. After settlements and reviews the total is $10,200, down 40%.

Most often, OSHA cited 1910.134, respiratory protection (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Steel Tek averages $8,400 over 1 cited inspection in that time.

Steel Tek: OSHA citation items per year, 2010 to 2017
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

58employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Steel Tek and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342094588 OPENED JAN 25, 2017Closed

Follow-up · Complete · Safety · 60 employees at the site · Closed Jan 27, 2017

4141 S. Jackson, Tulsa, OK 74107 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341096816 OPENED DEC 1, 2015Closed

Planned · Complete · Safety · 65 employees at the site · Closed Apr 11, 2016

4141 S. Jackson, Tulsa, OK 74107 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,100$1,050Feb 19, 2016Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Feb 19, 2016Final
Citation 1, item 1c
29 CFR 1910.107(g)(5) · Spray painting and finishing
Serious$0$0Feb 19, 2016Final
Citation 1, item 2
29 CFR 1910.110(f)(6)(i) · Storage and handling of liquefied petroleum gases
Serious$2,100$1,050Feb 19, 2016Final
Citation 1, item 3a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$2,100$1,050Feb 19, 2016Final
Citation 1, item 3b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Feb 19, 2016Final
Citation 1, item 3c
29 CFR 1910.134(i)(5)(iv) · Respiratory protection
Serious$0$0Feb 19, 2016Final
Citation 1, item 4b
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$0$1,750Feb 19, 2016Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,500$1,750Feb 19, 2016Final
Citation 1, item 6a
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$3,500$1,750Feb 19, 2016Final
Citation 1, item 6b
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$0$0Feb 19, 2016Final
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 19, 2016Final
Citation 2, item 2
29 CFR 1910.304(b)(2) · Grounding and circuit protection
Other-than-serious$0$0Feb 19, 2016Final

Inspection 314928144 OPENED OCT 20, 2010Closed

Planned · Partial · Safety · 50 employees at the site · Closed Apr 18, 2011

4141 S. Jackson, Tulsa, OK 74107 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$3,780$1,800Mar 14, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(g)(5)

(5) Cleaning solvents. The use of solvents for cleaning operations shall be restricted to those having flashpoints not less than 100 °F.; however, for cleaning spray nozzles and auxiliary equipment, solvents having flashpoints not less than those normally used in spray operations may be used. Such cleaning shall be conducted inside spray booths and ventilating equipment operated during cleaning.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.304 · Grounding and circuit protection

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Oklahoma