Suffolk Auto Exchange: OSHA inspections and violations

Suffolk, Virginia · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

3inspections
21citation items
$2,975current penalties
Jun 28, 2016last inspection

Since 2011, OSHA inspectors have visited Suffolk Auto Exchange in Virginia 3 times.

The most recent inspection opened on Jun 28, 2016, in Suffolk.

In all, OSHA issued 21 citation items: 12 serious and 9 other-than-serious.

The proposed penalties came to $6,030; today they stand at $2,975, 51% less.

The rule cited most here is 1910.107 (spray painting and finishing), 5 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Suffolk Auto Exchange averages $1,935 across 1 cited inspection.

Suffolk Auto Exchange: OSHA citation items per year, 2011 to 2016
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Suffolk Auto Exchange and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341585842 OPENED JUN 28, 2016Closed

Unprogrammed other · Partial · Health · 5 employees at the site · Closed Oct 27, 2016

1214 Portsmouth Blvd, Suffolk, VA 23434 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$720$720Sep 1, 2016Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Sep 1, 2016Final
Citation 1, item 1c
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$0$0Sep 1, 2016Final
Citation 1, item 2
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$720$720Sep 1, 2016Final
Citation 1, item 3a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$495$495Sep 1, 2016Final
Citation 1, item 3b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 1, 2016Final

Inspection 315436766 OPENED MAR 8, 2011Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Aug 22, 2011

4021 W Washington Street, Suffolk, VA 23434 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR VAC0120
Other-than-serious$2,100$200Apr 26, 2011Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$525$525Apr 26, 2011Closed
Citation 1, item 3
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$525$0Apr 26, 2011Closed

Inspection 315362582 OPENED FEB 7, 2011Closed

Complaint · Partial · Health · 5 employees at the site · Closed May 30, 2011

4021 W Washington Street, Suffolk, VA 23434 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$315$315Mar 17, 2011Closed
Citation 1, item 1b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Mar 17, 2011Closed
Citation 1, item 1c
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$0$0Mar 17, 2011Closed
Citation 1, item 1d
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Mar 17, 2011Closed
Citation 1, item 1e
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Mar 17, 2011Closed
Citation 1, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$315$0Mar 17, 2011Closed
Citation 1, item 3a
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$315$0Mar 17, 2011Closed
Citation 1, item 3b
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 17, 2011Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Mar 17, 2011Closed
Citation 2, item 2
29 CFR 1910.106(e)(9) · Flammable liquids
Other-than-serious$0$0Mar 17, 2011Closed
Citation 2, item 3
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 17, 2011Closed
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 17, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.22 · General requirements

29 CFR 1910.307 · Hazardous (classified) locations

Other automotive body, paint, and interior repair and maintenance employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.