Inspection 343291993 OPENED JUL 12, 2018Closed
4130 N. Canal St., Jacksonville, FL 32209 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Jacksonville, Florida · Fluid Power Pump and Motor Manufacturing · NAICS 333996
Since 2018, OSHA inspectors have visited Sun Coast Hydraulic Electric Manufacturing, Inc. in Florida 2 times.
The most recent inspection opened on Jul 12, 2018 to follow up on an earlier case, in Jacksonville.
In all, OSHA issued 15 citation items: 9 serious and 6 other-than-serious.
The penalties, $19,401 in total, stand where OSHA first set them.
The rule cited most here is 1910.134 (respiratory protection), 7 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Sun Coast Hydraulic Electric Manufacturing, Inc. averages $19,401 across 1 cited inspection.
Florida · latest 90 days of OSHA records
315employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Sun Coast Hydraulic Electric Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company4130 N. Canal St., Jacksonville, FL 32209 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4130 N. Canal St., Jacksonville, FL 32209 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $5,174 | $5,174 | Apr 24, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.134(d)(1)(iii) · Respiratory protection |
Serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 1, item 1c 29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection |
Serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 1, item 1d 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 1, item 1e 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 1, item 1f 29 CFR 1910.134(k)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 1, item 1g 29 CFR 1910.134(l)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $6,467 | $6,467 | Apr 24, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $7,760 | $7,760 | Apr 24, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 2, item 2 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 2, item 3 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Other-than-serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 2, item 4a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 2, item 4b 29 CFR 1910.1200(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 24, 2018 | Final |
| Citation 2, item 4c 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 24, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(g)(1)
(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.