OSHA SearchOSHA records by employer

Sun Coast Hydraulic Electric Manufacturing, Inc.: OSHA inspections and violations

Jacksonville, Florida · Fluid Power Pump and Motor Manufacturing · NAICS 333996

2inspections
15citation items
$19,401current penalties
Jul 12, 2018last inspection

Since 2018, OSHA inspectors have visited Sun Coast Hydraulic Electric Manufacturing, Inc. in Florida 2 times.

The most recent inspection opened on Jul 12, 2018 to follow up on an earlier case, in Jacksonville.

In all, OSHA issued 15 citation items: 9 serious and 6 other-than-serious.

The penalties, $19,401 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Sun Coast Hydraulic Electric Manufacturing, Inc. averages $19,401 across 1 cited inspection.

Sun Coast Hydraulic Electric Manufacturing, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

315employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Sun Coast Hydraulic Electric Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343291993 OPENED JUL 12, 2018Closed

Follow-up · Partial · Safety · 30 employees at the site · Closed Aug 27, 2018

4130 N. Canal St., Jacksonville, FL 32209 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342884327 OPENED JAN 18, 2018Closed

Complaint · Complete · Safety · 30 employees at the site · Closed Oct 15, 2020

4130 N. Canal St., Jacksonville, FL 32209 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$5,174$5,174Apr 24, 2018Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 1c
29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 1d
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 1e
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 1f
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 1g
29 CFR 1910.134(l)(1) · Respiratory protection
Serious$0$0Apr 24, 2018Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$6,467$6,467Apr 24, 2018Final
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$7,760$7,760Apr 24, 2018Final
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Apr 24, 2018Final
Citation 2, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Apr 24, 2018Final
Citation 2, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Other-than-serious$0$0Apr 24, 2018Final
Citation 2, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 24, 2018Final
Citation 2, item 4b
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Apr 24, 2018Final
Citation 2, item 4c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Apr 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.252 · Welding fire safety

Other fluid power pump and motor manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.