OSHA SearchOSHA records by employer

Sun Superior Chipper Parts LLC: OSHA inspections and violations

Darlington, South Carolina · Construction Machinery Manufacturing · NAICS 333120

1inspections
15citation items
$2,050current penalties
Feb 11, 2016last inspection

Sun Superior Chipper Parts LLC has one OSHA inspection on record in South Carolina.

OSHA opened it on Feb 11, 2016 as a planned inspection, in Darlington.

From that inspection OSHA issued 15 citation items: 8 serious and 7 other-than-serious.

OSHA proposed $2,050 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.107, spray painting and finishing (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Sun Superior Chipper Parts LLC averages $2,050 over 1 cited inspection in that time.

Sun Superior Chipper Parts LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Sun Superior Chipper Parts LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341264216 OPENED FEB 11, 2016Closed

Planned · Complete · Safety · 13 employees at the site · Closed Aug 26, 2016

132 Industrial Way, Darlington, SC 29532 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$300$300Jun 6, 2016Final
Citation 1, item 2
29 CFR 1910.107(d)(3) · Spray painting and finishing
Serious$300$300Jun 6, 2016Final
Citation 1, item 3
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$300$300Jun 6, 2016Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$225$225Jun 6, 2016Final
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$100$100Jun 6, 2016Final
Citation 1, item 6
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$225$225Jun 6, 2016Final
Citation 1, item 7
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$225$225Jun 6, 2016Final
Citation 1, item 8
29 CFR 1910.242(b) · Hand and power tools
Serious$225$225Jun 6, 2016Final
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jun 6, 2016Final
Citation 2, item 2
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Jun 6, 2016Final
Citation 2, item 3
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Jun 6, 2016Final
Citation 2, item 4
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 6, 2016Final
Citation 2, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$150$150Jun 6, 2016Final
Citation 2, item 5b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jun 6, 2016Final
Citation 2, item 5c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jun 6, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(d)(3)

(3) Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

Other construction machinery manufacturing employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.