12inspections
51citation items
$6,775current penalties
Sep 17, 2018last inspection

Sunrise Fiberglass LLC has 12 OSHA inspections on record in Minnesota, the first in 1984.

OSHA's last visit started on Sep 17, 2018 as a planned inspection, in Wyoming.

Across those inspections OSHA issued 51 citation items: 36 serious, 1 repeat and 14 other-than-serious.

OSHA proposed $8,860 in penalties. After settlements and reviews the total is $6,775, down 24%.

Most often, OSHA cited 1910.1000, air contaminants (8 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Sunrise Fiberglass LLC averages $2,200 over 1 cited inspection in that time.

Sunrise Fiberglass LLC also files yearly injury logs with OSHA, summarized below.

Sunrise Fiberglass LLC: OSHA citation items per year, 1984 to 2018
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Sunrise Fiberglass LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343470860 OPENED SEP 17, 2018Closed

Planned · Complete · Health · 44 employees at the site · Closed Jul 31, 2019

5175 260th St, Wyoming, MN 55092 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$500$500Nov 16, 2018Final
Citation 1, item 2 Serious$600$400Nov 16, 2018Final
Citation 1, item 3 Serious$400$400Nov 16, 2018Final
Citation 1, item 4
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$600$600Nov 16, 2018Final
Citation 1, item 5a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$400$300Nov 16, 2018Final
Citation 1, item 5b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Nov 16, 2018Final

Inspection 341151439 OPENED DEC 2, 2015Closed

Planned · Complete · Safety · 43 employees at the site · Closed Dec 4, 2015

5175 260th St, Wyoming, MN 55092 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316219286 OPENED DEC 13, 2011Closed

Planned · Complete · Safety · 34 employees at the site · Closed Jan 20, 2012

5175 260th St, Wyoming, MN 55092 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(g)(1)(ia) · Respiratory protection
Serious$400$280Dec 28, 2011Closed

Inspection 312510506 OPENED AUG 20, 2008Closed

Planned · Complete · Health · 45 employees at the site · Closed Feb 2, 2009

5175 260th. St., P.o. Box 606, Wyoming, MN 55092 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$600$420Oct 9, 2008Closed
Citation 1, item 1b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Oct 9, 2008Closed
Citation 1, item 2a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$400$280Oct 9, 2008Closed
Citation 1, item 2b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Oct 9, 2008Closed

Inspection 309478717 OPENED SEP 27, 2005Closed

Planned · Complete · Safety · 40 employees at the site · Closed Oct 25, 2005

5175 260th. St., P.o. Box 606, Wyoming, MN 55092 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$200$140Oct 4, 2005Closed
Citation 1, item 2
29 CFR 1910.305(d) · Electrical wiring methods
Serious$200$140Oct 4, 2005Closed

Inspection 305873085 OPENED SEP 6, 2002Closed

Planned · Complete · Safety · 40 employees at the site · Closed Nov 20, 2002

5175 260th. St., P.o. Box 606, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$150$105Oct 10, 2002Closed
Citation 1, item 2
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$150$105Oct 10, 2002Closed
Citation 1, item 3
29 CFR 1910.107(b)(3) · Spray painting and finishing
Serious$200$140Oct 10, 2002Closed
Citation 1, item 4
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$150$105Oct 10, 2002Closed
Citation 1, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$150$105Oct 10, 2002Closed
Citation 1, item 6
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$150$105Oct 10, 2002Closed
Citation 1, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$200$140Oct 10, 2002Closed
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$100$70Oct 10, 2002Closed

Inspection 126562750 OPENED FEB 21, 1996Closed

Planned · Complete · Health · 36 employees at the site · Closed Aug 26, 1996

26467 Fallbrook Avenue, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(b)(4) · Exit route design
Serious$300$210May 16, 1996Closed
Citation 1, item 2
29 CFR 1910.37(f)(5) · Exit routes
Serious$300$210May 16, 1996Closed
Citation 1, item 3 Serious$400$280May 16, 1996Closed
Citation 1, item 4
29 CFR 1910.106(e)(2)(iib) · Flammable liquids
Serious$300$210May 16, 1996Closed
Citation 1, item 5a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$400$280May 16, 1996Closed
Citation 1, item 5b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0May 16, 1996Closed
Citation 1, item 6a
29 CFR 1910.134(b)(2) · Respiratory protection
Serious$400$280May 16, 1996Closed
Citation 1, item 6b
29 CFR 1910.134(e)(4) · Respiratory protection
Serious$0$0May 16, 1996Closed
Citation 1, item 6c
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Serious$0$0May 16, 1996Closed
Citation 1, item 7
29 CFR 1910.151(c) · First aid and eyewash
Serious$400$280May 16, 1996Closed
Citation 1, item 8a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$400$280May 16, 1996Closed
Citation 1, item 8b
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0May 16, 1996Closed
Citation 1, item 8c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0May 16, 1996Closed
Citation 2, item 1
29 CFR 1910.134(b)(10) · Respiratory protection
Other-than-serious$0$0May 16, 1996Closed

Inspection 111610119 OPENED MAY 3, 1990Closed

Referral · Partial · Health · 15 employees at the site · Closed Apr 2, 1991

26467 Fallbrook Avenue, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jul 19, 1990Closed
Citation 1, item 2
29 CFR 1910.107(b)(1) · Spray painting and finishing
Other-than-serious$0$0Jul 19, 1990Closed
4 older inspections

Inspection 107735417 OPENED DEC 27, 1989Closed

Planned · Complete · Safety · 14 employees at the site · Closed Feb 12, 1990

26467 Fallbrook Avenue, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$114$114Jan 24, 1990Closed
Citation 2, item 1
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Jan 24, 1990Closed
Citation 2, item 2
29 CFR 1910.107(f)(3) · Spray painting and finishing
Other-than-serious$0$0Jan 24, 1990Closed
Citation 2, item 3
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Jan 24, 1990Closed

Inspection 104579644 OPENED NOV 24, 1986Closed

Follow-up · Partial · Safety · 15 employees at the site · Closed Dec 1, 1986

26467 Fallbrook Avenue, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104537287 OPENED OCT 8, 1986Closed

Planned · Complete · Safety · 15 employees at the site · Closed Nov 24, 1986

26467 Fallbrook Avenue, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$87$87Oct 20, 1986Closed
Citation 2, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Repeat$133$133Oct 20, 1986Closed
Citation 3, item 1
29 CFR 1910.213(h)(3) · Woodworking machinery
Other-than-serious$0$0Oct 20, 1986Closed
Citation 3, item 2
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Oct 20, 1986Closed
Citation 3, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Oct 20, 1986Closed
Citation 3, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Oct 20, 1986Closed
Citation 3, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Oct 20, 1986Closed

Inspection 14893556 OPENED JUL 3, 1984Closed

Complaint · Partial · Safety · 36 employees at the site · Closed Aug 16, 1984

26467 Fallbrook Ave, Wyoming, MN 55092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$76$76Jul 16, 1984Closed
Citation 2, item 1
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Jul 16, 1984Closed
Citation 2, item 2 Other-than-serious$0$0Jul 16, 1984Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2018, the Wyoming site logged 7 recordable injuries or illnesses among about 40 workers: 16.2 per 100 full-time workers, against a median of 2.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Sunrise Fiberglass LLC
Wyoming · 2018
40 7016.22.3

Included with any plan: 1 more yearly log from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(2)(iib)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise