OSHA SearchOSHA records by employer

Superior Roll Forming Co. Inc.: OSHA inspections and violations

Valley City, Ohio · Custom Roll Forming · NAICS 332114

16inspections
83citation items
$196,890current penalties
Jul 1, 2021last inspection

OSHA has inspected Superior Roll Forming Co. Inc. 16 times in Ohio since 1984.

The latest one began on Jul 1, 2021 on a referral, in Valley City.

Those inspections ended with 83 citation items: 68 serious, 2 willful, 1 repeat and 12 other-than-serious.

Penalties were first proposed at $424,465 and now stand at $196,890, 54% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 10 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Superior Roll Forming Co. Inc. averages $17,448 (4 cited inspections).

Superior Roll Forming Co. Inc. also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Superior Roll Forming Co. Inc.: OSHA citation items per year, 1984 to 2021
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Superior Roll Forming Co. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345395388 OPENED JUL 1, 2021Closed

Referral · Partial · Health · 225 employees at the site · Closed Jan 24, 2022

5535 Wegman Rd., Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Incident on Jun 23, 2021: Employee burns face, arms, and chest, flammable ink catches

At 10:07 a.m. on June 23, 2021, an employee was working as a milling machine operator for a custom roll forming company. The employee was working on an ongoing setup process for line 12 that was anticipated to take several days. The process involved using a plasma cutter to manually cut metal pieces from a long extruded metal form. The employee had just made a cut of the metal when he caught on fire due to being covered in blue flammable ink. The employee was hospitalized to treat lacerations and first and second degree burns to his arms, chest and face.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$13,516$13,516Sep 8, 2021Final
Citation 1, item 1b
29 CFR 1910.252(a)(2)(iv) · Welding fire safety
Serious$0$0Sep 8, 2021Final
Citation 1, item 3
29 CFR 1910.252(b)(3) · Welding fire safety
Other-than-serious$13,516$5,406Sep 8, 2021Final

Inspection 344876925 OPENED AUG 12, 2020Closed

Referral · Partial · Safety · 210 employees at the site · Closed Dec 21, 2020

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Incident on Aug 6, 2020: Employee amputates fingers in belt and pulley

At 10:30 a.m. on August 6, 2020, an employee was looking for the source of a high pitch squeaking sound on the production line when he reached into the motor drive area of the punch press and was caught in the belt and pulley. The employee suffered an amputation of two fingers and one fingertip of his right hand and was treated without hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$6,940$5,000Sep 25, 2020Final
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$24,289$13,000Sep 25, 2020Final

Inspection 342941929 OPENED FEB 12, 2018Closed

Complaint · Partial · Safety · 350 employees at the site · Closed Dec 20, 2018

5535 Wegman Drive, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Incident on Feb 5, 2018: Employee catches finger in nip point and partially amputates

At 2:15 p.m. on February 5, 2018, an employee was changing out a die on a hydraulic cut off machine. The pneumatic air source was not locked out and it activated while the employee had his left ring finger in a nip point. The employee caught his finger in a nip point between the die and steel arm and amputated it. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$12,934$12,934Jul 9, 2018Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i)(b) · Lockout/tagout
Serious$0$0Jul 9, 2018Final
Citation 1, item 1c
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$0$0Jul 9, 2018Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$64,670$12,934Jul 9, 2018Final

Inspection 342115359 OPENED FEB 9, 2017Closed

Referral · Partial · Safety · 400 employees at the site · Closed Mar 16, 2017

5535 Wegman Drive, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Incident on Feb 7, 2017: Employee amputates tip of finger while loading coil on roll-

At 8:00 a.m. on February 7. 2017, an employee was tasked to change the coil on a steel roll-forming machine. A 7.5 Ton Trambeam crane (serial number: M549380) was used for removal of the old coil and placement of the replacement coil, which the employee was successful in doing fifteen minutes prior to the incident. The employee first loaded the coil onto the reel, and then pulled the coil chain out from behind the coil. Next, before expanding the mandrel to allow more room for the chain to be released from behind the coil, he fed the end of the coil chain through the underside of the coil and engaged the crane to lift the chain up. During lifting, the chain became stuck between the mandrel and the coil. As the employee was using the crane to lift the chain through, he placed his left hand inside the mandrel. The chain slipped through and pinched his finger between the chain and the coil, amputating the tip of his left middle finger.

No citations from this inspection.

Inspection 340613199 OPENED MAY 1, 2015Closed

Complaint · Partial · Safety · 300 employees at the site · Closed Jun 17, 2015

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340436047 OPENED MAR 2, 2015Closed

Referral · Partial · Safety · 300 employees at the site · Closed Sep 15, 2016

5535 Wegman Drive, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$70,000$7,000May 13, 2015Final

Inspection 339809352 OPENED JUN 16, 2014Closed

Referral · Partial · Safety · 325 employees at the site · Closed Jun 16, 2014

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339496515 OPENED NOV 20, 2013Closed

Complaint · Partial · Safety · 325 employees at the site · Closed Feb 13, 2015

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.217(b)(7)(iii) · Mechanical power presses
Serious$7,000$5,500May 13, 2014Final
Citation 2, item 2
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Repeat$38,500$40,000May 13, 2014Final
8 older inspections

Inspection 338601255 OPENED JAN 31, 2013Closed

Referral · Partial · Safety · 300 employees at the site · Closed May 10, 2013

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$4,000$1,700Apr 11, 2013Final
Citation 1, item 2
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$7,000$6,000Apr 11, 2013Final

Inspection 337512222 OPENED NOV 26, 2012Closed

Complaint · Partial · Safety · 325 employees at the site · Closed Apr 16, 2013

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$6,000$4,200Jan 7, 2013Final
Citation 1, item 1b
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$3,000$0Jan 7, 2013Final
Citation 1, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$3,000$2,100Jan 7, 2013Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$7,000$4,900Jan 7, 2013Final
Citation 1, item 4
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$5,000$3,500Jan 7, 2013Final

Inspection 307064477 OPENED OCT 30, 2003Closed

Complaint · Partial · Safety · 110 employees at the site · Closed Nov 5, 2004

5535 Wegman Road, Valley City, OH 44280 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,625$975Jan 14, 2004Final
Citation 1, item 2a
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$4,000$2,270Jan 14, 2004Final
Citation 1, item 2b
29 CFR 1910.147(e)(1) · Lockout/tagout
Serious$0$0Jan 14, 2004Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$975$585Jan 14, 2004Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,625$975Jan 14, 2004Final
Citation 1, item 5
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$1,625$975Jan 14, 2004Final
Citation 1, item 6
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$1,625$975Jan 14, 2004Final
Citation 1, item 8
29 CFR 1910.217(c)(2)(ib) · Mechanical power presses
Serious$1,625$975Jan 14, 2004Final
Citation 1, item 9
29 CFR 1910.217(c)(2)(iv) · Mechanical power presses
Serious$4,000$2,270Jan 14, 2004Final

Inspection 303487987 OPENED FEB 13, 2001Closed

Complaint · Partial · Safety · 85 employees at the site · Closed Nov 8, 2002

5535 Wegman Road, Valley City, OH 44280 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,000$1,200Jul 13, 2001Final
Citation 1, item 2
29 CFR 1910.147(d)(2) · Lockout/tagout
Serious$2,100$1,200Jul 13, 2001Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,100$1,200Jul 13, 2001Final
Citation 1, item 4
29 CFR 1910.217(b)(7)(iii) · Mechanical power presses
Other-than-serious$1,500$800Jul 13, 2001Final
Citation 1, item 5
29 CFR 1910.217(c)(2)(iv) · Mechanical power presses
Serious$3,000$1,200Jul 13, 2001Final
Citation 1, item 6
29 CFR 1910.217(d)(9)(i) · Mechanical power presses
Serious$1,200$1,200Jul 13, 2001Final
Citation 1, item 7a
29 CFR 1910.217(c)(3)(ie) · Mechanical power presses
Serious$3,000$1,200Jul 13, 2001Final

Inspection 118125756 OPENED AUG 17, 1999Closed

Planned · Partial · Health · 150 employees at the site · Closed Jun 2, 2000

5535 Wegman Road, Valley City, OH 44280 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,750$1,750Feb 3, 2000Closed
Citation 1, item 2a Serious$1,750$0Feb 3, 2000Closed
Citation 1, item 2b Serious$0$0Feb 3, 2000Closed
Citation 2, item 1 Other-than-serious$0$0Feb 3, 2000Closed

Inspection 103009254 OPENED AUG 4, 1999Closed

Planned · Complete · Safety · 150 employees at the site · Closed Nov 27, 2000

5535 Wegman Road, Valley City, OH 44280 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(1) · General requirements
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 1b
29 CFR 1910.22(b)(2) · General requirements
Serious$0$0Feb 3, 2000Closed
Citation 1, item 2
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 3
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,050$550Feb 3, 2000Closed
Citation 1, item 4a
29 CFR 1910.29(a)(3) · Manually propelled mobile ladder stands and scaffolds (towers)
Serious$3,500$1,800Feb 3, 2000Closed
Citation 1, item 4b
29 CFR 1910.29(a)(3)(vii) · Manually propelled mobile ladder stands and scaffolds (towers)
Serious$0$0Feb 3, 2000Closed
Citation 1, item 5
29 CFR 1910.36(b)(5) · Exit route design
Other-than-serious$1,050$0Feb 3, 2000Closed
Citation 1, item 6
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$2,450$1,250Feb 3, 2000Closed
Citation 1, item 7
29 CFR 1910.106(d)(7)(iii) · Flammable liquids
Serious$2,450$1,250Feb 3, 2000Closed
Citation 1, item 8a
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 8b
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Feb 3, 2000Closed
Citation 1, item 9a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$2,450$1,250Feb 3, 2000Closed
Citation 1, item 9b
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$0$0Feb 3, 2000Closed
Citation 1, item 9c
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Serious$0$0Feb 3, 2000Closed
Citation 1, item 11
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,500$1,800Feb 3, 2000Closed
Citation 1, item 12a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$1,200$0Feb 3, 2000Closed
Citation 1, item 12b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Feb 3, 2000Closed
Citation 1, item 13
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 14
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 15
29 CFR 1910.242(a) · Hand and power tools
Serious$1,050$550Feb 3, 2000Closed
Citation 1, item 16
29 CFR 1910.252(b)(2)(ia) · Welding fire safety
Serious$2,450$1,250Feb 3, 2000Closed
Citation 1, item 17
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$1,400$700Feb 3, 2000Closed
Citation 1, item 18
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$1,050$0Feb 3, 2000Closed
Citation 1, item 19
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 20
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 21
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,450$1,250Feb 3, 2000Closed
Citation 1, item 22
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$1,050$550Feb 3, 2000Closed
Citation 1, item 23
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$3,500$1,800Feb 3, 2000Closed
Citation 1, item 24
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Serious$3,500$1,800Feb 3, 2000Closed
Citation 1, item 25
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$1,400$700Feb 3, 2000Closed
Citation 1, item 26
29 CFR 1910.304(f)(7)(iii) · Grounding and circuit protection
Serious$1,050$550Feb 3, 2000Closed
Citation 1, item 27
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Serious$1,400$2,500Feb 3, 2000Closed
Citation 1, item 28
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$1,750$900Feb 3, 2000Closed
Citation 1, item 29
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$3,500$1,800Feb 3, 2000Closed
Citation 1, item 30
29 CFR 1910.333(a)(2) · Working near live electrical parts
Serious$1,750$900Feb 3, 2000Closed
Citation 2, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Willful$38,500$7,000Feb 3, 2000Closed
Citation 2, item 1b
29 CFR 1910.138(b) · Gloves and hand protection
Willful$0$0Feb 3, 2000Closed
Citation 3, item 1
29 CFR 1910.36(b)(4) · Exit route design
Other-than-serious$700$0Feb 3, 2000Closed
Citation 3, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$700$0Feb 3, 2000Closed

Inspection 302503719 OPENED DEC 7, 1998Closed

Complaint · Partial · Safety · 60 employees at the site · Closed May 24, 2000

777 West Smith Rd., Medina, OH 44256 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$2,330Mar 12, 1999Final
Citation 1, item 2
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Serious$1,000$670Mar 12, 1999Final
Citation 2, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 1999Final
Citation 2, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 12, 1999Final
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 12, 1999Final

Inspection 1297118 OPENED AUG 21, 1984Closed

Planned · No inspection · Safety · 40 employees at the site · Closed Aug 24, 1984

7728 Commerce Park Oval, Cleveland, OH 44131 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Valley City site logged 7 recordable injuries or illnesses among about 140 workers: 7.1 per 100 full-time workers, against a median of 4.0 for its industry. Those cases cost 5 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Superior Roll Forming LLC
Valley City · 2023
140 727.14.0
Superior Roll Forming Company
Valley City · 2021
225 17107.64.0
Superior Roll Forming
Valley City · 2017
329 1453.64.0

Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Jun 23, 2021, Valley City: Hospitalization · heat (thermal) burns, unspecified · multiple body parts, n.e.c.

An employee was using a plasma cutter to cut parts on a line's cutoff. Sparks from the cutter came into contact with a flammable liquid that was used to mark parts, and the employee suffered burns to the face, neck, chest, and arms in the resulting fire. He also suffered a head laceration.

Jan 4, 2018, Valley City: Hospitalization · heat (thermal) burns, unspecified · nonclassifiable

An employee was tied off from a railing performing work when an explosion occurred. The employee suffered severe burns and was hospitalized.

Feb 7, 2017, Valley City: Amputation · amputations · fingertip(s)

An employee was attempting to free a coil chain from a coil when his left middle finger was caught between the chain and the coil, amputating his fingertip.

Feb 21, 2015, Valley City: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

The employer reported an amputation that occurred on 1-21-2015 at approximately 3:00pm. The employee was working on a coil end welding machine when his left index finger was caught in a hydraulic clamp.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(7)(iii)

(iii) Open flames and smoking. Open flames and smoking shall not be permitted in flammable liquid storage areas.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.29 · Manually propelled mobile ladder stands and scaffolds (towers)

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.36 · Exit route design

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other custom roll forming employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.