Inspection 343773495 OPENED FEB 7, 2019Closed
921 Seaco Court, Deer Park, TX 77536 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2018, OSHA inspectors have visited Swaby Manufacturing Company in Texas 3 times.
The most recent inspection opened on Feb 7, 2019, in Deer Park.
In all, OSHA issued 19 citation items: 10 serious and 9 other-than-serious.
The proposed penalties came to $11,649; today they stand at $3,886, 67% less.
The rule cited most here is 1910.134 (respiratory protection), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Swaby Manufacturing Company averages $1,943 across 2 cited inspections.
Texas · latest 90 days of OSHA records
399employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Swaby Manufacturing Company and get notified the morning OSHA posts a new citation for it.
Watch this company921 Seaco Court, Deer Park, TX 77536 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
921 Seaco Court, Deer Park, TX 77536 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $2,217 | $1,330 | Aug 6, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.138(a) · Gloves and hand protection |
Serious | $1,663 | $998 | Aug 6, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.213(g)(1) · Woodworking machinery |
Serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.213(g)(2) · Woodworking machinery |
Serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 1, item 6a 29 CFR 1910.1200(g)(1) · Hazard communication |
Serious | $1,663 | $998 | Aug 6, 2018 | Final |
| Citation 1, item 6b 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 2 29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 3 29 CFR 1910.107(b)(9) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 4 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $311 | $187 | Aug 6, 2018 | Final |
| Citation 2, item 5a 29 CFR 1910.134(c)(3) · Respiratory protection |
Other-than-serious | $311 | $187 | Aug 6, 2018 | Final |
| Citation 2, item 5b 29 CFR 1910.134(d)(1)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 5c 29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 5d 29 CFR 1910.134(f)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 6, 2018 | Final |
| Citation 2, item 6 29 CFR 1910.151(c) · First aid and eyewash |
Other-than-serious | $311 | $187 | Aug 6, 2018 | Final |
921 Seaco Court, Deer Park, TX 77536 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks |
Serious | $2,217 | $0 | Jun 15, 2018 | Final |
| Citation 1, item 2a 29 CFR 1910.215(a)(2) · Grinders and abrasive wheels |
Serious | $2,956 | $0 | Jun 15, 2018 | Final |
| Citation 1, item 2b 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jun 15, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.