Inspection 342957032 OPENED FEB 14, 2018Closed
320 West Springdale Rd, Rock Hill, SC 29730 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rock Hill, South Carolina · Drywall and Insulation Contractors · NAICS 238310
OSHA has inspected Tailored Foam Inc 7 times in South Carolina since 1988.
The latest one began on Feb 14, 2018 to follow up on an earlier case, in Rock Hill.
Those inspections ended with 16 citation items: 5 serious and 11 other-than-serious.
Penalties were first proposed at $7,000 and now stand at $2,400, 66% lower after settlements or reviews.
Hazard communication comes up most often in these citations: 6 items under 1926.59.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Tailored Foam Inc averages $2,100 (1 cited inspection).
1 inspection on this page followed a fatal incident.
South Carolina · latest 90 days of OSHA records
43employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Tailored Foam Inc and get notified the morning OSHA posts a new citation for it.
Watch this company320 West Springdale Rd, Rock Hill, SC 29730 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
320 W Springdale Rd, Rock Hill, SC 29730 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Mar 4, 2017 (fatal): Employee strikes head on an overhead beam and is killed
On March 4, 2017, Employee #1 and a coworker were spraying damp proofing product on the exposed brick at the Rock Hill High School courtyard. The employees were working out of an aerial lift Genie, Serial number Z30N11-12902. The height of the courtyard was 31 feet. Once they finished that area, they were instructed to go to the other side of the building and finish that area before the end of the day. The two employees began spraying that side of the building at approximately 3:45 p.m. At 5:30 p.m., Employee #1 entered the area on a JLG aerial lift, Model number 400S, serial number 0300165229. The employee set the lift up, facing away from the building. Employee #1 maneuvered the lift so that the basket would fit in the 11 feet by 10 feet opening. The opening had an overhead beam that came out of the building at 22 feet in height. The overhead was six feet in width by eight feet in length, leaving four feet to the end of the opening. The speed of the lift was placed in the fast (rabbit) mode. Once Employee #1 began to accelerate, the lift moved straight up. The back of Employee #1's head and neck struck the overhead steel beam. When Employee #1 struck the beam, it pushed his body forward onto the controls, propelling the machine to keep moving upward. Employee #1 sustained crushing injuries to his head and neck, killing him. killing him.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $2,500 | $2,100 | Aug 29, 2017 | Final |
| Citation 1, item 3b 29 CFR 1926.454(a) · Scaffold training |
Serious | $4,200 | $0 | Aug 29, 2017 | Final |
1720 Ebenezer Rd., Rock Hill, SC 29731 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.302(b)(2) · Power-operated hand tools |
Serious | $0 | $0 | Jun 20, 2002 | Closed |
Hwy 378 At St. Peters Church Road, Lexington, SC 29072 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $300 | $300 | Sep 25, 1998 | Closed |
| Citation 1, item 1b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | Sep 25, 1998 | Closed |
4350 St. Andrews Road, Columbia, SC 29210 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Route 2, Duncan Road U.s. 176, Union, SC 29379 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.28(a) · Personal protective equipment |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
| Citation 1, item 2 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
| Citation 1, item 3 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
| Citation 1, item 4 29 CFR 1926.59(e)(2) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
| Citation 1, item 5 29 CFR 1926.59(f)(5) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
| Citation 1, item 6 29 CFR 1926.59(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
| Citation 1, item 7 29 CFR 1926.59(h) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 1, 1989 | Closed |
7665 Northwoods Blvd., N. Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 30005 D |
Other-than-serious | $0 | $0 | Mar 23, 1988 | Closed |
| Citation 1, item 2 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Mar 23, 1988 | Closed |
| Citation 1, item 3 29 CFR 1926.405(a)(2)(iii) · Job-site wiring |
Other-than-serious | $0 | $0 | Mar 23, 1988 | Closed |
| Citation 1, item 4 29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Mar 23, 1988 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.28(a)
(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.
29 CFR 1926.302(b)(2)
(2) Safety clips or retainers shall be securely installed and maintained on pneumatic impact (percussion) tools to prevent attachments from being accidentally expelled.
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.