OSHA SearchOSHA records by employer

Tec Installations, Inc.: OSHA inspections and violations

Paterson, New Jersey · Conveyor and Conveying Equipment Manufacturing · NAICS 333922

4inspections
38citation items
$13,668current penalties
Apr 4, 2017last inspection

Since 1986, OSHA inspectors have visited Tec Installations, Inc. in New Jersey 4 times.

The most recent inspection opened on Apr 4, 2017 on a referral, in Paterson.

In all, OSHA issued 38 citation items: 12 serious and 26 other-than-serious.

The proposed penalties came to $26,902; today they stand at $13,668, 49% less.

The rule cited most here is 1910.1200 (hazard communication), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Tec Installations, Inc. averages $6,084 across 2 cited inspections.

Tec Installations, Inc.: OSHA citation items per year, 1986 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Tec Installations, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342219854 OPENED APR 4, 2017Closed

Referral · Partial · Health · 14 employees at the site · Closed Aug 10, 2017

375 E 22nd St, Paterson, NJ 07514 · Conveyor and Conveying Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(5) · Exit routes
Other-than-serious$2,173$0Jun 21, 2017Final
Citation 1, item 2
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$2,173$1,304Jun 21, 2017Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$2,173$1,304Jun 21, 2017Final
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 21, 2017Final
Citation 1, item 3c
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Jun 21, 2017Final
Citation 2, item 1
29 CFR 1910.138(b) · Gloves and hand protection
Other-than-serious$0$0Jun 21, 2017Final
Citation 2, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 21, 2017Final
Citation 2, item 2b
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jun 21, 2017Final
Citation 2, item 2c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jun 21, 2017Final

Inspection 342178910 OPENED MAR 16, 2017Closed

Referral · Partial · Safety · 14 employees at the site · Closed Dec 14, 2017

375 E 22nd St, Paterson, NJ 07514 · Conveyor and Conveying Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Mar 16, 2017: Employee is struck by metal grate and fractures leg

At 9:45 a.m. on March 16, 2017, an employee was guiding the forklift driver that was carrying a metal grate into the building. The employee was struck by the 3 foot by 15 foot metal grate and fractured his lower left leg. The employee was hospitalized and treated for his injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(o)(1) · Forklifts and other powered industrial trucks
Serious$5,070$2,788Jun 21, 2017Final
Citation 1, item 1b
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$0$0Jun 21, 2017Final
Citation 1, item 2a
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Serious$2,173$1,195Jun 21, 2017Final
Citation 1, item 2b
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$0$0Jun 21, 2017Final
Citation 1, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$5,070$2,788Jun 21, 2017Final
Citation 1, item 4a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$5,070$2,788Jun 21, 2017Final
Citation 1, item 4b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jun 21, 2017Final

Inspection 312864630 OPENED APR 9, 2010Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Oct 29, 2010

156 Huron Ave, Clifton, NJ 07013 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Apr 9, 2010: Three employees suffer burns when gas ignites

At approximately 10:00 a.m. on April 9, 2010, Employees #1, #2, and #3 sustained second and third degree burns to their faces and hands. The propylene cylinder gas in the box truck had apparently leaked in the box area of the truck. Upon op ening the truck rear door, the gas flowed approximately 8 feet towards the build ing furnace and apparently, the gas was ignited by the pilot light causing the g as to flash.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$1,500$750Jul 19, 2010Closed
Citation 1, item 2a
29 CFR 1910.253(b)(5)(iiia) · Gas welding and cutting
Serious$1,500$750Jul 19, 2010Closed
Citation 1, item 2b
29 CFR 1910.253(b)(5)(iiib) · Gas welding and cutting
Serious$0$0Jul 19, 2010Closed

Inspection 101627529 OPENED JUN 3, 1986Closed

Complaint · Complete · Safety · 25 employees at the site · Closed Jul 31, 1986

375 E. 22nd Street, Paterson, NJ 07514 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 2
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 3
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 4
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 6
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 7
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 8
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 9
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 10
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 11
29 CFR 1910.252(e)(2)(iii) · Welding fire safety
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 12
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 13
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 14
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 15
29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 16
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 17
29 CFR 1910.1200(f)(4) · Hazard communication
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 18
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jun 20, 1986Closed
Citation 1, item 19
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jun 20, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ivd)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other conveyor and conveying equipment manufacturing employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.