OSHA SearchOSHA records by employer

Temperature Specialists Inc: OSHA inspections and violations

Saint Francis, Minnesota · Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use · NAICS 334512

3inspections
21citation items
$9,830current penalties
Apr 7, 2015last inspection

Temperature Specialists Inc has 3 OSHA inspections on record in Minnesota, the first in 2006.

OSHA's last visit started on Apr 7, 2015 as a planned inspection, in St Francis.

Across those inspections OSHA issued 21 citation items: 17 serious and 4 other-than-serious.

OSHA proposed $10,400 in penalties. After settlements and reviews the total is $9,830, down 5%.

Most often, OSHA cited 1910.147, lockout/tagout (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Temperature Specialists Inc averages $1,330 over 1 cited inspection in that time.

Temperature Specialists Inc: OSHA citation items per year, 2006 to 2015
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

380employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Temperature Specialists Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317978831 OPENED APR 7, 2015Closed

Planned · Complete · Health · 49 employees at the site · Closed Jun 1, 2015

3175 Bridge St Nw, St Francis, MN 55070 · Other Measuring and Controlling Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$300$210Apr 30, 2015Closed
Citation 1, item 1b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Apr 30, 2015Closed
Citation 1, item 1c
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Apr 30, 2015Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$300$210Apr 30, 2015Closed
Citation 1, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$400$280Apr 30, 2015Closed
Citation 1, item 4
29 CFR 1910.252(b)(2)(i)(a) · Welding fire safety
Serious$300$210Apr 30, 2015Closed
Citation 1, item 5
29 CFR 1910.1026(l)(1) · Hexavalent chromium
Serious$400$280Apr 30, 2015Closed
Citation 2, item 1
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Other-than-serious$200$140Apr 30, 2015Closed

Inspection 316391630 OPENED MAR 7, 2012Closed

Planned · Complete · Safety · 48 employees at the site · Closed Apr 18, 2012

3175 Bridge St, Saint Francis, MN 55070 · Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$600$600Mar 21, 2012Closed
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,000$1,000Mar 21, 2012Closed
Citation 1, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$1,000$1,000Mar 21, 2012Closed
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,000$1,000Mar 21, 2012Closed
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,400$1,400Mar 21, 2012Closed
Citation 1, item 6
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,000$1,000Mar 21, 2012Closed
Citation 1, item 7 Serious$800$800Mar 21, 2012Closed
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Mar 21, 2012Closed
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$200$200Mar 21, 2012Closed
Citation 2, item 3 Other-than-serious$0$0Mar 21, 2012Closed

Inspection 310529359 OPENED SEP 21, 2006Closed

Planned · Complete · Safety · 35 employees at the site · Closed Oct 23, 2006

3175 Bridge St, Saint Francis, MN 55070 · Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$450$450Oct 2, 2006Closed
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$450$450Oct 2, 2006Closed
Citation 1, item 3 Serious$600$600Oct 2, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1026(l)(1)

(l) Communication of chromium (VI) hazards to employees—(1) Hazard communication—general—(i) Chemical manufacturers, importers, distributors and employers shall comply with all requirements of the Hazard Communication Standard (HCS) (§ 1910.1200) for chromium (VI).

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.332 · Training

29 CFR 5206.700

Other automatic environmental control manufacturing for residential, commercial, and appliance use employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.