OSHA SearchOSHA records by employer

Terry's Electric, Inc.: OSHA inspections and violations

Kissimmee, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

27inspections
25citation items
$21,755current penalties
Jul 9, 2024last inspection

OSHA has inspected Terry's Electric, Inc. 27 times in Florida since 1983.

The latest one began on Jul 9, 2024 on a referral, in Kissimmee.

Those inspections ended with 25 citation items: 9 serious, 1 repeat and 15 other-than-serious.

Penalties were first proposed at $90,650 and now stand at $21,755, 76% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 6 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Terry's Electric, Inc. averages $3,600 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Terry's Electric, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.

Terry's Electric, Inc.: OSHA citation items per year, 1983 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Terry's Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347605511 OPENED JUL 9, 2024Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 22, 2024

1520 Erin Breeze Lane, Kissimmee, FL 34744 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345200802 OPENED MAR 3, 2021Closed

Planned · Complete · Safety · 20 employees at the site · Closed Aug 30, 2021

117 Massachusetts Ave, Lakeland, FL 33801 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343652665 OPENED DEC 11, 2018Closed

Complaint · Partial · Safety · 50 employees at the site · Closed Feb 21, 2019

Lockheed Martin W. Perimeter Rd., Orlando, FL 32801 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341298693 OPENED MAR 3, 2016Closed

Referral · Complete · Safety · 16 employees at the site · Closed Sep 19, 2016

145 E. Lakeshore Blvd., Kissimmee, FL 34744 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.201(a) · Signaling
Serious$5,000$3,000Jul 29, 2016Final
Citation 2, item 1
29 CFR 1904.32(b)(3) · Yearly injury summary
Other-than-serious$1,000$600Jul 29, 2016Final

Inspection 339646093 OPENED MAR 24, 2014Closed

Unprogrammed related · Partial · Safety · 30 employees at the site · Closed Jun 12, 2014

6857 Turkey Lake Rd., Orlando, FL 32819 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 335376380 OPENED JUL 6, 2012Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Sep 4, 2012

2600 County Line Road, Lakeland, FL 33811 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Other-than-serious$4,410$2,205Aug 6, 2012Final

Inspection 306847948 OPENED OCT 8, 2003Closed

Unprogrammed other · Complete · Safety · 20 employees at the site · Closed May 17, 2004

3080 Arabian Knights Blvd., Kissimmee, FL 34747 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305222630 OPENED FEB 15, 2002Closed

Unprogrammed related · Complete · Safety · 23 employees at the site · Closed Mar 28, 2002

2999 Parkway Blvd, Kissimmee, FL 34747 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

19 older inspections

Inspection 304246960 OPENED JUL 13, 2001Closed

Unprogrammed related · Partial · Safety · 800 employees at the site · Closed Jul 26, 2001

Boca Marina Addition, Boca Raton, FL 33431 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304264948 OPENED MAR 8, 2001Closed

Accident · Complete · Safety · 30 employees at the site · Closed Mar 22, 2002

Cason Rd & Coronet Rd, Plant City, FL 33564 · OSHA's record · Phone and website on Google Maps

Incident on Mar 7, 2001 (fatal): Electric shock - contact with overhead line thru light pole

A local utility company hired an electrical contractor to install new streetligh ting at the corner of a hazardous intersection. The job required installing one of the streetlights parallel to an existing 13.2-kilovolt (phase-to-phase) overh ead power line. The ground worker installed the streetlighting hardware and supp ly cable on the pole, placed a synthetic nylon sling with a choker hitch around the pole, and attached the sling to the load line of a derrick truck. When the d errick lifted the pole to an upright position, the derrick's tilt-pole plumber a rms grasped the shaft of the pole. The operator of the derrick truck swung the l oad around and began to set the pole in a 1.8-meter-deep hole. The ground worker was securing the cargo straps to the pole trailer as the derrick operator was s etting the pole. When the butt end of the pole contacted the bottom of the hole, the pole spun the streetlight into the overhead line. The ground worker ran to the pole to try to prevent it from contacting the overhead line. He was electroc uted when he touched the supply cable on the pole. He had entry and exit wounds on his right hand and right heel.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Other-than-serious$7,000$7,000Aug 1, 2001Final
Citation 1, item 1b Other-than-serious$0$0Aug 1, 2001Final
Citation 2, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$70,000$7,000Aug 1, 2001Final

Inspection 109212944 OPENED JUN 8, 1999Closed

Unprogrammed other · Complete · Safety · 19 employees at the site · Closed Jun 30, 1999

217 Boston Ave., Altamonte Springs, FL 32701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109210344 OPENED NOV 23, 1998Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 13, 1999

17950 Tennis Court Loop, Clermont, FL 34711 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$1,125$550Dec 16, 1998Closed

Inspection 109209411 OPENED OCT 7, 1998Closed

Planned · Complete · Safety · 13 employees at the site · Closed Dec 23, 1998

6984 Grand Vacations Way, Orlando, FL 32821 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(d) · Job-site wiring
Serious$975$600Nov 18, 1998Closed
Citation 1, item 1b
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Nov 18, 1998Closed
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Nov 18, 1998Closed
Citation 2, item 2
29 CFR 1926.405(a)(2)(iic) · Job-site wiring
Other-than-serious$0$0Nov 18, 1998Closed
Citation 2, item 3
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Other-than-serious$0$0Nov 18, 1998Closed
Citation 2, item 4
29 CFR 1926.416(b)(2) · Electrical safety in construction
Other-than-serious$0$0Nov 18, 1998Closed

Inspection 109204172 OPENED SEP 29, 1997Closed

Planned · Complete · Safety · 3 employees at the site · Closed Oct 30, 1997

258 Southhall Lane, Maitland, FL 32751 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109017350 OPENED APR 23, 1996Closed

Planned · Complete · Safety · 20 employees at the site · Closed Apr 29, 1996

Caribe Royale Resort Suites, Int'l Dr & Sr 535, Orlando, FL 32821 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109709717 OPENED JAN 12, 1994Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Feb 11, 1994

801 N. Us 27, Clermont, FL 32711 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106499304 OPENED OCT 30, 1992Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Nov 9, 1992

2300 Poinciana Blvd., Kissimmee, FL 34759 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106489701 OPENED MAR 17, 1992Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 3, 1992

2155 Lakeside Drive, Kissimmee, FL 34744 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 106204399 OPENED DEC 13, 1990Closed

Planned · Complete · Safety · 6 employees at the site · Closed Apr 11, 1991

5335 U.s. 192 East, Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$400$200Jan 11, 1991Closed

Inspection 17666777 OPENED JUN 4, 1990Closed

Unprogrammed related · Complete · Safety · 7 employees at the site · Closed Jun 8, 1990

948 Wymore Road, Winter Park, FL 32789 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 102960622 OPENED APR 11, 1989Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Apr 18, 1989

1845 Ave A, Poinciana Industrial Park, Poinciana, FL 32758 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 102964145 OPENED SEP 13, 1988Closed

Unprogrammed related · Complete · Safety · 10 employees at the site · Closed Oct 31, 1988

5874 West Irlo Bronson Memorial Highway, Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Oct 19, 1988Closed
Citation 1, item 2
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Oct 19, 1988Closed

Inspection 101877652 OPENED APR 29, 1986Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 29, 1986

5770 W. Spacecoast Pkwy., Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 2460921 OPENED SEP 9, 1985Closed

Follow-up · Partial · Safety · 2 employees at the site · Closed Sep 12, 1985

4786 W. Space Coast Parkway, Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 2461408 OPENED JUL 16, 1985Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 16, 1985

4786 West Space Coast Parkway, Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.400(c)(1) · Introduction
Serious$350$210Aug 1, 1985Closed
Citation 1, item 1b
29 CFR 1926.400(c)(2) · Introduction
Serious$0$0Aug 1, 1985Closed
Citation 2, item 1
29 CFR 1926.400(h)(1) · Introduction
Repeat$140$140Aug 1, 1985Closed
Citation 3, item 1
29 CFR 1926.402(c)(4) · Applicability
Other-than-serious$0$0Aug 1, 1985Closed

Inspection 1697283 OPENED MAY 16, 1984Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Sep 17, 1986

Best Western Eastgate Motel Sr192, Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$250$250May 24, 1984Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0May 24, 1984Closed
Citation 2, item 2 Other-than-serious$0$0May 24, 1984Closed

Inspection 14084628 OPENED AUG 11, 1983Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Sep 9, 1983

4510 W Space Coast, Kissimmee, FL 32741 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Aug 31, 1983Closed
Citation 1, item 2
29 CFR 1926.400(h)(1) · Introduction
Other-than-serious$0$0Aug 31, 1983Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Kissimmee site logged 6 recordable injuries or illnesses among about 350 workers: 2.1 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Terry's Electric
Kissimmee · 2025
350 602.11.8
Terry's Electric - Util
Orlando · 2025
50 000.01.8
Terry's Electric
Orlando · 2024
50 000.01.8
Terry's Electric Lake Nona Commercial
Kissimmee · 2021
85 505.71.8

Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jun 26, 2024, Kissimmee: Hospitalization · sprains, strains, tears unspecified · ankle(s)

An employee was installing a light box while standing on a 2x6 board over a 15-foot tall opening when the board snapped, causing them to fall to the ground. The employee sustained ligament damage to their ankle.

Feb 26, 2016, Kissimmee: Hospitalization · electrical burns, unspecified · multiple body parts, n.e.c.

An employee was in a bucket running wire from a transformer when they received burns across the upper torso and hands due to an arcing power line.

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jan 9, 2017 to Jan 8, 2019
Kissimmee
20$0$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(3)

(3) How do I certify the annual summary? A company executive must certify that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete.

29 CFR 1926.201 · Signaling

29 CFR 1926.201(a)

(a) Flaggers. Signaling by flaggers and the use of flaggers, including warning garments worn by flaggers, shall conform to Part 6 of the MUTCD (incorporated by reference, see § 1926.6).

29 CFR 1926.21 · Construction safety training

29 CFR 1926.25 · Housekeeping

29 CFR 1926.400 · Introduction

29 CFR 1926.402 · Applicability

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.550 · [Reserved]

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.