OSHA SearchOSHA records by employer

Tex Art Stone: OSHA inspections and violations

Keller, Texas · Cut Stone and Stone Product Manufacturing · NAICS 327991

3inspections
9citation items
$11,381current penalties
Apr 26, 2018last inspection

Tex Art Stone has 3 OSHA inspections on record in Texas, the first in 1995.

OSHA's last visit started on Apr 26, 2018 on a referral, in Keller.

Across those inspections OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

OSHA proposed $20,693 in penalties. After settlements and reviews the total is $11,381, down 45%.

Most often, OSHA cited 1910.305, electrical wiring methods (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Tex Art Stone averages $11,381 over 1 cited inspection in that time.

Tex Art Stone: OSHA citation items per year, 1995 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Tex Art Stone and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343140166 OPENED APR 26, 2018Closed

Referral · Partial · Health · 11 employees at the site · Closed May 8, 2018

8900 Davis Blvd, Keller, TX 76248 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343064291 OPENED APR 3, 2018Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Jun 22, 2018

8900 Davis Blvd, Keller, TX 76248 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.27(a) · Scaffolds and rope descent systems
Serious$5,174$2,846Apr 17, 2018Final
Citation 1, item 2
29 CFR 1910.37(b)(2) · Exit routes
Serious$2,217$1,219Apr 17, 2018Final
Citation 1, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$2,217$1,219Apr 17, 2018Final
Citation 1, item 4
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$2,217$1,219Apr 17, 2018Final
Citation 1, item 5
29 CFR 1910.303(e) · Electrical equipment, general requirements
Serious$2,956$1,626Apr 17, 2018Final
Citation 1, item 6a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,956$1,626Apr 17, 2018Final
Citation 1, item 6b
29 CFR 1910.305(b)(3)(ii) · Electrical wiring methods
Serious$0$0Apr 17, 2018Final
Citation 1, item 7
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$2,217$1,219Apr 17, 2018Final
Citation 2, item 1
29 CFR 1904.32(a) · Yearly injury summary
Other-than-serious$739$407Apr 17, 2018Final

Inspection 110041571 OPENED AUG 24, 1995Closed

Planned · No inspection · Safety · 8 employees at the site · Closed Aug 25, 1995

8900 Davis Blvd., Fort Worth, TX 76180 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)

(a) Basic requirement. At the end of each calendar year, you must:

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(f)(3)

(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.

29 CFR 1910.27 · Scaffolds and rope descent systems

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other cut stone and stone product manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.