OSHA SearchOSHA records by employer

Texoma Contracting, Inc.: OSHA inspections and violations

Watonga, Oklahoma · Structural Steel and Precast Concrete Contractors · NAICS 238120

2inspections
5citation items
$11,840current penalties
Dec 15, 2015last inspection

Texoma Contracting, Inc. has 2 OSHA inspections on record in Oklahoma, the first in 2005.

OSHA's last visit started on Dec 15, 2015 on a referral, in Spiro.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $13,450 in penalties. After settlements and reviews the total is $11,840, down 12%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Texoma Contracting, Inc. averages $7,000 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

It reported 1 severe injury to OSHA since 2015.

Texoma Contracting, Inc.: OSHA citation items per year, 2005 to 2015
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

53employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Texoma Contracting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341126548 OPENED DEC 15, 2015Closed

Referral · Partial · Safety · 45 employees at the site · Closed Dec 28, 2016

23886 Racetrack Rd, Spiro, OK 74959 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$7,000$7,000Mar 2, 2016Final

Inspection 308063056 OPENED APR 26, 2005Closed

Accident · Partial · Safety · 4 employees at the site · Closed May 11, 2006

Watonga Downtown Cellular Tower, Watonga, OK 73772 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 26, 2005 (fatal): Employee killed in fall from communication tower

At approximately 7:45 a.m. on April 26, 2005, Employee #1 and a coworker were in stalling co-axial cables that would connect cellular antennas. The antennas, loc ated on an existing 360 ft tall, triangular communication tower, were to be conn ected to an equipment building at the base of the tower. At approximately 10:15 a.m., after the cables had been installed, Employee #1 needed to move across the co-axial cables that had been suspended from the tower. As he was doing so, he fell about 240 ft and was killed. Subsequent investigation revealed that both wo rkers were wearing safety harnesses with positioning devices. These devices conn ected to D-rings on the sides of their harnesses and allowed them to connect to the tower braces in front of them. However, neither employee was wearing a lanya rd that connected to the back of their harnesses.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,500$1,125Sep 7, 2005Closed
Citation 1, item 2
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,100$1,575Sep 7, 2005Closed
Citation 1, item 3
29 CFR 1926.95(b) · Criteria for personal protective equipment
Serious$750$565Sep 7, 2005Closed
Citation 1, item 4
29 CFR 1926.105(a) · Safety nets
Serious$2,100$1,575Sep 7, 2005Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 8, 2015, Spiro: Hospitalization, amputation · electrical burns, unspecified · multiple body parts, n.e.c.

On December 7, 2015, an employee received an electrical shock when the steel cables attached to the spider basket in which the employee was working contacted an overhead power line. The employee suffered electrical burns to the right hand and stomach and the amputation of his right arm just below the elbow.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.105 · Safety nets

29 CFR 1926.105(a)

(a) Safety nets shall be provided when workplaces are more than 25 feet above the ground or water surface, or other surfaces where the use of ladders, scaffolds, catch platforms, temporary floors, safety lines, or safety belts is impractical.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.95 · Criteria for personal protective equipment

OSH Act Section 5 · General Duty Clause

Other structural steel and precast concrete contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.