OSHA SearchOSHA records by employer

The Lintern Corporation: OSHA inspections and violations

Mentor, Ohio · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

6inspections
56citation items
$11,340current penalties
Feb 23, 2015last inspection

OSHA has inspected The Lintern Corporation 6 times in Ohio since 1974.

The latest one began on Feb 23, 2015 as a planned inspection, in Mentor.

Those inspections ended with 56 citation items: 5 serious and 51 other-than-serious.

Penalties were first proposed at $14,000 and now stand at $11,340, 19% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 6 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and The Lintern Corporation averages $11,000 (1 cited inspection).

The Lintern Corporation: OSHA citation items per year, 1974 to 2015
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

263employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch The Lintern Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340419233 OPENED FEB 23, 2015Closed

Planned · Complete · Safety · 32 employees at the site · Closed Feb 29, 2016

8658 Station St., Mentor, OH 44060 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$2,800$2,000Apr 24, 2015Final
Citation 1, item 1b
29 CFR 1910.138(a) · Gloves and hand protection
Other-than-serious$0$0Apr 24, 2015Final
Citation 1, item 1c
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Apr 24, 2015Final
Citation 1, item 4a
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Other-than-serious$3,500$2,000Apr 24, 2015Final
Citation 1, item 4b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Other-than-serious$0$0Apr 24, 2015Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,500$3,500Apr 24, 2015Final
Citation 1, item 6
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$3,500Apr 24, 2015Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Apr 24, 2015Final

Inspection 1285030 OPENED SEP 25, 1984Closed

Planned · No inspection · Safety · 94 employees at the site · Closed Sep 28, 1984

8669 Station St, Mentor, OH 44060 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 214776221 OPENED JAN 24, 1984Closed

Planned · Complete · Safety · 94 employees at the site · Closed Nov 19, 1984

8665 Station St, Mentor, OH 44060 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$120$60Mar 15, 1984Closed
Citation 1, item 2
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$40$20Mar 15, 1984Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$40$20Mar 15, 1984Closed
Citation 2, item 2
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 3
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 4
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 5
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 6a
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 6b
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 7
29 CFR 1910.107(b)(1) · Spray painting and finishing
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 8
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 9
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 10
29 CFR 1910.107(b)(6) · Spray painting and finishing
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 11
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 12
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 13
29 CFR 1910.145(f)(1)(i) · Specifications for accident prevention signs and tags
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 14
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 15, 1984Closed
Citation 2, item 15
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 16
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 17
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 18
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 19
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Feb 27, 1984Closed
Citation 2, item 20
29 CFR 1910.305(g)(1)(iiid) · Electrical wiring methods
Other-than-serious$0$0Feb 27, 1984Closed

Inspection 214834830 OPENED MAR 2, 1982Closed

Planned · Complete · Health · 111 employees at the site · Closed Apr 28, 1982

8669 Station St 81, Mentor, OH 44060 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$360$100Mar 30, 1982Closed
Citation 2, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Mar 10, 1982Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 10, 1982Closed

Inspection 215003633 OPENED DEC 23, 1974Closed

Follow-up · Complete · Safety · 82 employees at the site · Closed Mar 10, 1984

8669 Station Road, Mentor, OH 44060 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 215002981 OPENED SEP 10, 1974Closed

Planned · Complete · Safety · 82 employees at the site · Closed Mar 10, 1984

8669 Station Street, Mentor, OH 44060 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(a)(1) · Portable fire extinguishers
Other-than-serious$25$25Sep 23, 1974Closed
Citation 1, item 2
29 CFR 1910.157(a)(5) · Portable fire extinguishers
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 3
29 CFR 1910.157(d)(2)(i) · Portable fire extinguishers
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 4
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 5
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 6
29 CFR 1910.252(e)(2)(iii) · Welding fire safety
Other-than-serious$25$25Sep 23, 1974Closed
Citation 1, item 7
29 CFR 1910.252(a)(2)(iv) · Welding fire safety
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 8
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 9
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$25$25Sep 23, 1974Closed
Citation 1, item 10
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 11
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 12
29 CFR 1910.213(i)(1) · Woodworking machinery
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 13
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 14
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 15
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 16
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 17 Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 18 Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 19 Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 20 Other-than-serious$0$0Sep 23, 1974Closed
Citation 1, item 21
29 CFR 1910.106(d)(4) · Flammable liquids
Other-than-serious$40$40Sep 23, 1974Closed
Citation 1, item 22
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$25$25Sep 23, 1974Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.309

Other all other miscellaneous fabricated metal product manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.