OSHA has inspected The Skydyne Company 12 times in New York since 1975.
The latest one began on Jul 5, 2016 on a referral, in Port Jervis.
Those inspections ended with 49 citation items: 39 serious, 2 repeat and 8 other-than-serious.
Penalties were first proposed at $81,865 and now stand at $32,117, 61% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 5 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and The Skydyne Company averages $6,037 (3 cited inspections).
The Skydyne Company also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Port Jervis site logged 0 recordable injuries or illnesses among about 25 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
the skydyne company
Port Jervis · 2020
25
0
0
0.0
2.8
1965
Port Jervis · 2017
25
2
2
38.5
2.8
Included with any plan: 2 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jun 27, 2016, Port Jervis: Amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee was clearing a jam in the shear when the machine activated via the foot pedal and amputated three right-hand fingers above the second joint. The machine was unguarded at the time of the incident.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.106(e)(9)(iii)
(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.