Thermal Pipe Systems, Inc.: OSHA inspections and violations

Durant, Oklahoma · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · NAICS 331210

2inspections
12citation items
$6,950current penalties
Apr 19, 2017last inspection

Since 2007, OSHA inspectors have visited Thermal Pipe Systems, Inc. in Oklahoma 2 times.

The most recent inspection opened on Apr 19, 2017 after a complaint, in Durant.

In all, OSHA issued 12 citation items: 8 serious and 4 other-than-serious.

The proposed penalties came to $12,496; today they stand at $6,950, 44% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Thermal Pipe Systems, Inc. averages $5,000 across 1 cited inspection.

Thermal Pipe Systems, Inc.: OSHA citation items per year, 2007 to 2017
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

58employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Thermal Pipe Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342270352 OPENED APR 19, 2017Closed

Complaint · Complete · Health · 15 employees at the site · Closed Mar 20, 2020

4913 Armstrong Rd., Durant, OK 74702 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$3,622$1,700Oct 3, 2017Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Oct 3, 2017Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,897$1,400Oct 3, 2017Final
Citation 1, item 3a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,897$1,400Oct 3, 2017Final
Citation 1, item 3b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Oct 3, 2017Final
Citation 2, item 1
29 CFR 1904.32(a)(3) · Yearly injury summary
Other-than-serious$724$300Oct 3, 2017Final
Citation 2, item 2
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Oct 3, 2017Final
Citation 2, item 3
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Other-than-serious$406$200Oct 3, 2017Final

Inspection 310999040 OPENED JUN 22, 2007Closed

Planned · Partial · Safety · 12 employees at the site · Closed Oct 19, 2007

4913 Armstrong Rd., Durant, OK 74702 · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$750$750Aug 31, 2007Closed
Citation 1, item 2
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$750$750Aug 31, 2007Closed
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$450$450Aug 31, 2007Closed
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 31, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(3)

(3) Certify the summary; and

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.305 · Electrical wiring methods

Other iron and steel pipe and tube manufacturing from purchased steel employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.