OSHA SearchOSHA records by employer

Thermatron Engineering, Inc.: OSHA inspections and violations

Methuen, Massachusetts · Power Boiler and Heat Exchanger Manufacturing · NAICS 332410

5inspections
11citation items
$7,467current penalties
Oct 25, 2017last inspection

OSHA has inspected Thermatron Engineering, Inc. 5 times in Massachusetts since 1998.

The latest one began on Oct 25, 2017 as a planned inspection, in Methuen.

Those inspections ended with 11 citation items: 11 serious.

Penalties were first proposed at $12,480 and now stand at $7,467, 40% lower after settlements or reviews.

Machine guarding comes up most often in these citations: 4 items under 1910.212.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Thermatron Engineering, Inc. averages $5,592 (1 cited inspection).

Thermatron Engineering, Inc. also files yearly injury logs with OSHA, summarized below.

Thermatron Engineering, Inc.: OSHA citation items per year, 1998 to 2017
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

235employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Thermatron Engineering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342744919 OPENED OCT 25, 2017Closed

Planned · Partial · Health · 55 employees at the site · Closed Nov 21, 2017

687 Lowell Street, Methuen, MA 01844 · Engineering Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341883288 OPENED NOV 2, 2016Closed

Referral · Partial · Safety · 46 employees at the site · Closed Sep 6, 2017

687 Lowell Street, Methuen, MA 01844 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$8,730$5,592Dec 1, 2016Final

Inspection 341566438 OPENED JUN 22, 2016Closed

Planned · No inspection · Health · 50 employees at the site · Closed Jun 22, 2016

687 Lowell Street, Methuen, MA 01844 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303858005 OPENED SEP 23, 2002Closed

Complaint · Partial · Safety · 21 employees at the site · Closed Feb 14, 2003

687 Lowell Street, Methuen, MA 01844 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$300$150Jan 2, 2003Closed
Citation 1, item 1b
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Jan 2, 2003Closed
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$375$188Jan 2, 2003Closed
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jan 2, 2003Closed
Citation 1, item 2c
29 CFR 1910.134(l)(1) · Respiratory protection
Serious$0$0Jan 2, 2003Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$300$150Jan 2, 2003Closed
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$375$188Jan 2, 2003Closed
Citation 1, item 5
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$300$150Jan 2, 2003Closed

Inspection 113542518 OPENED AUG 19, 1998Closed

Referral · Partial · Safety · 12 employees at the site · Closed Nov 10, 1998

687 Lowell Street, Methuen, MA 01844 · OSHA's record · Phone and website on Google Maps

Incident on Aug 19, 1998: Employee's fingertip amputated on table saw

At approximately 10:30 a.m. on August 19, 1998, Employee #1, a technician for Th ermatron Engineering, Inc., in Methuen MA, was using a Mackenzie table saw, mode l #58650, to cut off approximately 1 in. from the length of pieces of CDA 110 co pper tubing to be used in a heat exchange unit. He had already cut about 12 piec es when he shouted to coworkers for help because he had amputated the end of his right little finger. Emergency Services responded and wrapped the severed tip i n cellophane before transporting Employee #1 to Holy Family Hospital in Methuen, MA.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,500$750Oct 7, 1998Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$600$300Oct 7, 1998Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Methuen site logged 2 recordable injuries or illnesses among about 57 workers: 3.1 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Thermatron Engineering Inc
Methuen · 2023
57 203.12.8
Thermatron Engineering
Methuen · 2022
50 305.82.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

Other power boiler and heat exchanger manufacturing employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.