OSHA SearchOSHA records by employer

Thermo Products, LLC: OSHA inspections and violations

Denton, North Carolina · Heating Equipment (except Warm Air Furnaces) Manufacturing · NAICS 333414

9inspections
67citation items
$19,950current penalties
Jan 25, 2022last inspection

Thermo Products, LLC has 9 OSHA inspections on record in North Carolina, the first in 1984.

OSHA's last visit started on Jan 25, 2022 on a referral, in Denton.

Across those inspections OSHA issued 67 citation items: 29 serious and 38 other-than-serious.

OSHA proposed $32,701 in penalties. After settlements and reviews the total is $19,950, down 39%.

Most often, OSHA cited 1910.217, mechanical power presses (12 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Thermo Products, LLC averages $3,820 over 2 cited inspections in that time.

Thermo Products, LLC also files yearly injury logs with OSHA, summarized below.

Thermo Products, LLC: OSHA citation items per year, 1984 to 2022
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Thermo Products, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345743249 OPENED JAN 25, 2022Closed

Referral · Partial · Safety · 80 employees at the site · Closed Apr 14, 2022

92 West Fourth Street, Denton, NC 27239 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$3,500$2,345Mar 15, 2022Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Mar 15, 2022Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$3,045Mar 15, 2022Final
Citation 2, item 1
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 15, 2022Final

Inspection 341600757 OPENED JUL 5, 2016Closed

Planned · Complete · Safety · 48 employees at the site · Closed Aug 3, 2016

92 W 4th Street, Denton, NC 27239 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$750$750Jul 14, 2016Final
Citation 1, item 2a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$750$750Jul 14, 2016Final
Citation 1, item 2b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jul 14, 2016Final
Citation 1, item 3a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$750$750Jul 14, 2016Final
Citation 1, item 3b
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Jul 14, 2016Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jul 14, 2016Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jul 14, 2016Final
Citation 2, item 3
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 14, 2016Final
Citation 2, item 4
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Jul 14, 2016Final

Inspection 313599862 OPENED AUG 21, 2009Closed

Planned · Records only · Health · 47 employees at the site · Closed Sep 22, 2009

92 West 4th Street, Denton, NC 27239 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309511384 OPENED DEC 21, 2005Closed

Planned · Complete · Safety · 74 employees at the site · Closed May 8, 2006

92 West Fourth Street, Denton, NC 27239 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$1,375$1,025Jan 31, 2006Closed
Citation 1, item 2
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$1,375$1,025Jan 31, 2006Closed
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 2
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 3
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 4
29 CFR 1910.133(a)(2) · Eye and face protection
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 5
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 6
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 7
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 31, 2006Closed
Citation 2, item 8
29 CFR 1910.1200(h)(1)(i) · Hazard communication
Other-than-serious$0$0Jan 31, 2006Closed

Inspection 304545577 OPENED AUG 16, 2001Closed

Referral · Partial · Health · 64 employees at the site · Closed Oct 19, 2001

92 West Fourth Street, Denton, NC 27239 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304544661 OPENED JUL 19, 2001Closed

Planned · Complete · Safety · 64 employees at the site · Closed Oct 2, 2001

92 West Fourth Street, Denton, NC 27239 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(h)(6)(ib) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Aug 20, 2001Closed
Citation 1, item 2
29 CFR 1910.110(h)(6)(iib) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Aug 20, 2001Closed
Citation 1, item 3
29 CFR 1910.110(h)(7) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Aug 20, 2001Closed
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 20, 2001Closed
Citation 1, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 20, 2001Closed

Inspection 302465448 OPENED NOV 23, 1998Closed

Planned · Complete · Safety · 58 employees at the site · Closed Mar 17, 1999

92 West 4th Street, Denton, NC 27237 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(4) · Spray painting and finishing
Serious$313$230Jan 5, 1999Closed
Citation 1, item 1b
29 CFR 1910.107(b)(6) · Spray painting and finishing
Serious$0$0Jan 5, 1999Closed
Citation 1, item 1c
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Jan 5, 1999Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$313$230Jan 5, 1999Closed
Citation 1, item 3a
29 CFR 1910.179(b)(3) · Overhead and gantry cranes
Serious$875$640Jan 5, 1999Closed
Citation 1, item 3b
29 CFR 1910.179(e)(1)(iii) · Overhead and gantry cranes
Serious$0$0Jan 5, 1999Closed
Citation 1, item 3c
29 CFR 1910.179(e)(4) · Overhead and gantry cranes
Serious$0$0Jan 5, 1999Closed
Citation 1, item 3d
29 CFR 1910.179(e)(2)(i) · Overhead and gantry cranes
Serious$0$0Jan 5, 1999Closed
Citation 1, item 3e
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$0$0Jan 5, 1999Closed
Citation 1, item 3f
29 CFR 1910.179(k)(2) · Overhead and gantry cranes
Serious$0$0Jan 5, 1999Closed
Citation 1, item 3g
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Serious$0$0Jan 5, 1999Closed
Citation 2, item 1
29 CFR 1910.110(b)(6)(vi) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jan 5, 1999Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jan 5, 1999Closed
Citation 2, item 3
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jan 5, 1999Closed
Citation 2, item 4
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 5, 1999Closed

Inspection 125242610 OPENED MAR 27, 1995Closed

Accident · Partial · Safety · 68 employees at the site · Closed Jan 5, 2011

92 West 4th Street, Denton, NC 27237 · OSHA's record · Phone and website on Google Maps

Incident on Mar 13, 1995: Employee's fingers amputated in mechanical power press

At approximately 10:30 p.m. on March 13, 1995, Employee #1 was stamping metal pa rts on a mechanical power press activated by a foot pedal. A part was stuck in t he die so he reached with his right hand to remove it. Employee #1 activated the foot pedal, causing the press to cycle and to amputate four fingers.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$5,600$5,600Apr 26, 1995Closed
Citation 1, item 1b
29 CFR 1910.217(d)(1)(ii) · Mechanical power presses
Serious$0$0Apr 26, 1995Closed
Citation 1, item 1c
29 CFR 1910.217(f)(2) · Mechanical power presses
Serious$0$0Apr 26, 1995Closed
Citation 1, item 2a
29 CFR 1910.217(d)(9)(i) · Mechanical power presses
Serious$5,600$1,000Apr 26, 1995Closed
Citation 1, item 2b
29 CFR 1910.217(d)(9)(iv) · Mechanical power presses
Serious$0$0Apr 26, 1995Closed
Citation 1, item 3a
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$5,600$1,000Apr 26, 1995Closed
Citation 1, item 3b
29 CFR 1910.217(e)(3) · Mechanical power presses
Serious$0$0Apr 26, 1995Closed
Citation 1, item 4
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$1,200$780Apr 26, 1995Closed
Citation 2, item 1
29 CFR 1910.38(a)(2) · Emergency action plans
Other-than-serious$0$0Apr 26, 1995Closed
Citation 2, item 2
29 CFR 1910.38(b)(1) · Emergency action plans
Other-than-serious$0$0Apr 26, 1995Closed
Citation 2, item 3
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Other-than-serious$0$0Apr 26, 1995Closed
Citation 2, item 4
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Apr 26, 1995Closed
Citation 2, item 5a
29 CFR 1910.217(d)(6)(i) · Mechanical power presses
Other-than-serious$1,200$780Apr 26, 1995Closed
Citation 2, item 5b
29 CFR 1910.217(d)(6)(iii) · Mechanical power presses
Other-than-serious$0$0Apr 26, 1995Closed
1 older inspection

Inspection 14972376 OPENED JUN 13, 1984Closed

Planned · Complete · Safety · 43 employees at the site · Closed Jul 30, 1984

Jones St, Denton, NC 27239 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 2
29 CFR 1910.110(h)(12) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 4
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 6
29 CFR 1910.217(b)(7)(viii) · Mechanical power presses
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 7
29 CFR 1910.217(b)(7)(ix) · Mechanical power presses
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 8
29 CFR 1910.217(d)(9)(iv) · Mechanical power presses
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 9
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 24, 1984Closed
Citation 1, item 10
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Jul 24, 1984Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Denton site logged 1 recordable injury or illness among about 84 workers: 3.4 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Thermo Products, LLC
Denton · 2025
84 103.42.4
Thermo Products
Denton · 2021
82 11113.72.4

Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(6)

(6) Frontal area. Each spray booth having a frontal area larger than 9 square feet shall have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.38 · Emergency action plans

Other heating equipment (except warm air furnaces) manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.