Thompson Masonry Contracting Company: OSHA inspections and violations

Bethlehem, Pennsylvania · Masonry Contractors · NAICS 238140

18inspections
46citation items
$47,639current penalties
Apr 1, 2026last inspection

OSHA has inspected Thompson Masonry Contracting Company 18 times in Pennsylvania since 1994.

The latest one began on Apr 1, 2026 after a complaint, in Media.

Those inspections ended with 46 citation items: 31 serious, 1 repeat and 14 other-than-serious.

Penalties were first proposed at $74,081 and now stand at $47,639, 36% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 15 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Thompson Masonry Contracting Company averages $3,281 (4 cited inspections).

1 inspection on this page followed a fatal incident.

Thompson Masonry Contracting Company: OSHA citation items per year, 1994 to 2026
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

268employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Thompson Masonry Contracting Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348848193 OPENED APR 1, 2026Closed

Complaint · Partial · Health · 10 employees at the site · Closed Sep 22, 2026

111 Elwyn Road, Media, PA 19063 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348432287 OPENED AUG 12, 2025Open

Referral · Partial · Safety · 20 employees at the site · Open

110 Park Ave., Swarthmore, PA 19081 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Other-than-serious$3,972$2,780Jan 22, 2026Final

Inspection 348346396 OPENED JUL 1, 2025Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Jul 28, 2026

1119 Monocacy St, Bethlehem, PA 18018 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$3,972$2,780Dec 27, 2025Final
Citation 1, item 1b
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$0$0Dec 27, 2025Final

Inspection 348180928 OPENED APR 15, 2025Closed

Referral · Partial · Safety · 29 employees at the site · Closed Sep 25, 2025

110 Park Ave., Swarthmore, PA 19081 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347282154 OPENED FEB 15, 2024Closed

Referral · Partial · Safety · 7 employees at the site · Closed May 28, 2024

846 Cross Street, Pottstown, PA 19464 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Feb 14, 2024 (fatal): Employee is killed when struck by piv

At 9:00 a.m. on February 14, 2024, an employee working for a masonry contractor was walking into a shop when he was struck by a Pettibone Telehandler and killed.

No citations from this inspection.

Inspection 342662566 OPENED SEP 26, 2017Closed

Planned · Partial · Safety · 10 employees at the site · Closed Apr 1, 2019

S. New And W. Third Streets, Bethlehem, PA 18015 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,579$3,400Oct 19, 2017Final

Inspection 340561810 OPENED APR 15, 2015Closed

Programmed other · Partial · Safety · 7 employees at the site · Closed Nov 3, 2016

Notre Dame Of Bethlehem - Catholic Elementary School 1835 Catasauqua Road, Bethlehem, PA 18018 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(g)(2)(i) · Fall protection systems
Serious$2,975$4,165Apr 23, 2015Final
Citation 1, item 1b
29 CFR 1926.502(g)(3)(iii) · Fall protection systems
Serious$0$0Apr 23, 2015Final
Citation 1, item 1c
29 CFR 1926.502(g)(2)(iii) · Fall protection systems
Serious$2,975$0Apr 23, 2015Final

Inspection 315816694 OPENED SEP 13, 2011Closed

Planned · Partial · Safety · 60 employees at the site · Closed May 2, 2013

1000 Purple Pride Parkway, Phoenixville, PA 19460 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,900$3,500Jan 24, 2012Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$4,200$0Jan 24, 2012Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Repeat$8,400$4,000Jan 24, 2012Final
Citation 3, item 1
29 CFR 1904.32(a)(1) · Yearly injury summary
Other-than-serious$2,000$500Jan 24, 2012Final
10 older inspections

Inspection 314725482 OPENED AUG 19, 2011Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Feb 6, 2012

Moravian College Field House, Bethlehem, PA 18018 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Other-than-serious$2,023$2,023Sep 6, 2011Final

Inspection 311266118 OPENED AUG 10, 2007Closed

Unprogrammed related · Partial · Safety · 10 employees at the site · Closed Oct 3, 2007

700 Welsh Road, Huntingdon Valley, PA 19006 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$2,000Aug 29, 2007Closed

Inspection 309861979 OPENED OCT 24, 2006Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jan 9, 2007

5th Ave., Perkasie, PA 18944 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$493$493Oct 31, 2006Closed

Inspection 309860732 OPENED SEP 15, 2006Closed

Planned · Partial · Safety · 17 employees at the site · Closed Jan 9, 2007

800 Maple Ave., Harleysville, PA 19438 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$419$419Oct 4, 2006Closed
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$658$658Oct 4, 2006Closed

Inspection 112899703 OPENED DEC 10, 2001Closed

Planned · Complete · Safety · 27 employees at the site · Closed Feb 8, 2002

Amity Intermediate School, 200 Boone Drive, Douglassville, PA 19518 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$900$585Jan 9, 2002Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Jan 9, 2002Closed
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jan 9, 2002Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$900$585Jan 9, 2002Closed
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$900$585Jan 9, 2002Closed

Inspection 300992195 OPENED NOV 20, 1997Closed

Planned · Complete · Safety · 25 employees at the site · Closed Apr 2, 1998

Lewis Road, Royersford, PA 19468 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,125$565Jan 30, 1998Closed
Citation 1, item 1b
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$0$0Jan 30, 1998Closed
Citation 1, item 1c
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$0$0Jan 30, 1998Closed
Citation 2, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$1,800$900Jan 30, 1998Closed
Citation 3, item 1
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Other-than-serious$0$0Jan 30, 1998Closed
Citation 3, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Other-than-serious$0$0Jan 30, 1998Closed

Inspection 301445409 OPENED JUN 17, 1997Closed

Complaint · Partial · Safety · 60 employees at the site · Closed Sep 3, 1998

North Five Points Rd., Lots 3 & 5, West Chester, PA 19380 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,000$2,000Aug 20, 1997Closed
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Other-than-serious$765$500Aug 20, 1997Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,100$1,500Aug 20, 1997Closed
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,000$2,000Aug 20, 1997Closed
Citation 1, item 6
29 CFR 1926.451(h)(2)(iii) · Scaffolds, general requirements
Serious$1,200$700Aug 20, 1997Closed
Citation 1, item 8
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$900$400Aug 20, 1997Closed
Citation 1, item 9
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$1,500$700Aug 20, 1997Closed
Citation 1, item 10a
29 CFR 1926.25(a) · Housekeeping
Serious$0$2,100Aug 20, 1997Closed
Citation 1, item 10b
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Aug 20, 1997Closed
Citation 2, item 1
29 CFR 1926.501(b)(15) · Fall protection in construction
Unclassified$6,000$4,500Aug 20, 1997Closed
Citation 3, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Aug 20, 1997Closed

Inspection 300988508 OPENED FEB 20, 1997Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 28, 1997

3250 State Road, Sellersville, PA 18960 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$500$500Feb 27, 1997Closed
Citation 2, item 1
29 CFR 1926.403(a) · Electrical equipment on job sites
Other-than-serious$0$0Feb 27, 1997Closed

Inspection 122031743 OPENED MAY 7, 1996Closed

Referral · Partial · Safety · 13 employees at the site · Closed Jun 27, 1996

College Drive, Pottstown, PA 19464 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$1,225$650May 14, 1996Closed
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$700$350May 14, 1996Closed

Inspection 17711391 OPENED JUN 9, 1994Closed

Unprogrammed related · Complete · Safety · 60 employees at the site · Closed Jan 9, 1995

Front & Erie Sts., Philadelphia, PA 19140 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,000$600Jul 6, 1994Closed
Citation 1, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$1,000$600Jul 6, 1994Closed
Citation 1, item 3
29 CFR 1926.500(b)(2) · Scope, application, and definitions applicable to this subpart
Serious$1,000$600Jul 6, 1994Closed
Citation 2, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Jul 6, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(1)

(1) Review the OSHA 300 Log to verify that the entries are complete and accurate, and correct any deficiencies identified;

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.25 · Housekeeping

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

OSH Act Section 5 · General Duty Clause