OSHA SearchOSHA records by employer

Tivolitoo Inc: OSHA inspections and violations

Mendota Heights, Minnesota · All Other Miscellaneous Wood Product Manufacturing · NAICS 321999

3inspections
17citation items
$3,313current penalties
Jun 2, 2016last inspection

OSHA has inspected Tivolitoo Inc 3 times in Minnesota since 2009.

The latest one began on Jun 2, 2016 as a planned inspection, in Saint Paul.

Those inspections ended with 17 citation items: 15 serious and 2 other-than-serious.

Penalties were first proposed at $4,725 and now stand at $3,313, 30% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 5 items under 1910.213.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Tivolitoo Inc averages $1,600 (1 cited inspection).

Tivolitoo Inc: OSHA citation items per year, 2009 to 2016
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Tivolitoo Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341522035 OPENED JUN 2, 2016Closed

Planned · Complete · Health · 35 employees at the site · Closed Jan 6, 2017

2444 Enterprise Drive, Suite A, Saint Paul, MN 55120 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(ii)(b)(2) · Flammable liquids
Serious$300$300Aug 4, 2016Final
Citation 1, item 2
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$500$500Aug 4, 2016Final
Citation 1, item 3
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$300$300Aug 4, 2016Final
Citation 1, item 4a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$300$300Aug 4, 2016Final
Citation 1, item 4b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Aug 4, 2016Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$200$200Aug 4, 2016Final

Inspection 316611110 OPENED JUL 24, 2012Closed

Planned · Complete · Safety · 20 employees at the site · Closed Sep 6, 2012

2444 Enterprise Drive, Suite A, Mendota Heights, MN 55120 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$375$262Aug 15, 2012Closed
Citation 1, item 2a
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$375$262Aug 15, 2012Closed
Citation 1, item 2b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Aug 15, 2012Closed

Inspection 312833577 OPENED JAN 14, 2009Closed

Planned · Complete · Safety · 25 employees at the site · Closed May 7, 2009

2444 Enterprise Drive, Suite A, Mendota Heights, MN 55120 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Feb 12, 2009Closed
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$375$188Feb 12, 2009Final
Citation 1, item 3
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$375$188Feb 12, 2009Final
Citation 1, item 4
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$375$187Feb 12, 2009Final
Citation 1, item 5
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$375$187Feb 12, 2009Final
Citation 1, item 6
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$500$250Feb 12, 2009Final
Citation 1, item 7 Serious$375$188Feb 12, 2009Final
Citation 2, item 1 Other-than-serious$0$0Feb 12, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)(b)(2)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 5206.700

Other all other miscellaneous wood product manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.