TNT Equipment Company: OSHA inspections and violations

Columbus, Ohio · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

3inspections
17citation items
$32,775current penalties
Apr 17, 2018last inspection

TNT Equipment Company has 3 OSHA inspections on record in Ohio, the first in 1993.

OSHA's last visit started on Apr 17, 2018 after a complaint, in Somerset.

Across those inspections OSHA issued 17 citation items: 13 serious and 4 other-than-serious.

OSHA proposed $60,789 in penalties. After settlements and reviews the total is $32,775, down 46%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. TNT Equipment Company averages $29,025 over 1 cited inspection in that time.

TNT Equipment Company: OSHA citation items per year, 1993 to 2018
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch TNT Equipment Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343093027 OPENED APR 17, 2018Closed

Complaint · Partial · Health · 17 employees at the site · Closed Mar 13, 2020

7070 State Route 13, Somerset, OH 43783 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$7,114$4,268Sep 12, 2018Final
Citation 1, item 4
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$7,114$4,268Sep 12, 2018Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,691$3,415Sep 12, 2018Final
Citation 1, item 6a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$7,114$4,268Sep 12, 2018Final
Citation 1, item 6b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 12, 2018Final
Citation 1, item 7a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$7,114$4,268Sep 12, 2018Final
Citation 1, item 7b
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$0$0Sep 12, 2018Final
Citation 1, item 8
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Serious$7,114$4,268Sep 12, 2018Final
Citation 1, item 9a
29 CFR 1910.303(b)(1)(iv) · Electrical equipment, general requirements
Serious$7,114$4,268Sep 12, 2018Final
Citation 1, item 9b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$7,114$0Sep 12, 2018Final
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Sep 12, 2018Final
Citation 2, item 3
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Sep 12, 2018Final
Citation 2, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Sep 12, 2018Final

Inspection 300541174 OPENED MAR 6, 2001Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 20, 2002

2291 Federated Blvd, Columbus, OH 45439 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$2,500$1,875Mar 30, 2001Final
Citation 1, item 1b
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$0$0Mar 30, 2001Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$2,500$1,875Mar 30, 2001Final

Inspection 121902043 OPENED NOV 5, 1993Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Dec 29, 1993

5865 Chantry Drive, Columbus, OH 43232 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$300$0Dec 13, 1993Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1926.451 · Scaffolds, general requirements

Other ornamental and architectural metal work manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.