OSHA SearchOSHA records by employer

Tournesol Siteworks: OSHA inspections and violations

El Paso, Texas · Other Concrete Product Manufacturing · NAICS 327390

1inspections
11citation items
$21,304current penalties
Oct 25, 2018last inspection

OSHA has inspected Tournesol Siteworks once in Texas.

The inspection began on Oct 25, 2018 after a complaint, in El Paso.

That inspection ended with 11 citation items: 8 serious and 3 other-than-serious.

Penalties were first proposed at $50,389 and now stand at $21,304, 58% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Tournesol Siteworks averages $21,304 (1 cited inspection).

Tournesol Siteworks also files yearly injury logs with OSHA, summarized below.

Tournesol Siteworks: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Tournesol Siteworks and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343559613 OPENED OCT 25, 2018Closed

Complaint · Partial · Health · 26 employees at the site · Closed Sep 1, 2020

1148 Barranca Dr., El Paso, TX 79935 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Other-than-serious$5,304$3,000Mar 11, 2019Final
Citation 1, item 3
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$3,978$2,500Mar 11, 2019Final
Citation 1, item 4a
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$5,304$3,000Mar 11, 2019Final
Citation 1, item 4b
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$5,304$0Mar 11, 2019Final
Citation 1, item 6a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$5,304$3,000Mar 11, 2019Final
Citation 1, item 6b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$3,978$0Mar 11, 2019Final
Citation 1, item 6c
29 CFR 1910.305(c)(4) · Electrical wiring methods
Serious$5,304$0Mar 11, 2019Final
Citation 1, item 9
29 CFR 1910.307(c)(2)(i) · Hazardous (classified) locations
Serious$5,304$5,304Mar 11, 2019Final
Citation 1, item 11
29 CFR 1910.1200(a)(1) · Hazard communication
Serious$3,978$2,500Mar 11, 2019Final
Citation 1, item 12
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$5,304$1,000Mar 11, 2019Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$1,327$1,000Mar 11, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the El Paso site logged 0 recordable injuries or illnesses among about 21 workers: 0.0 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Location 4 / EP
El Paso · 2023
21 000.02.6

Included with any plan: 2 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

Other other concrete product manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.