OSHA SearchOSHA records by employer

Tracery Stone Inc.: OSHA inspections and violations

Birmingham, Alabama · Cut Stone and Stone Product Manufacturing · NAICS 327991

1inspections
5citation items
$5,654current penalties
Aug 13, 2018last inspection

OSHA has inspected Tracery Stone Inc. once in Alabama.

The inspection began on Aug 13, 2018 after a complaint, in Birmingham.

That inspection ended with 5 citation items: 3 serious and 2 other-than-serious.

Penalties were first proposed at $9,423 and now stand at $5,654, 40% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Tracery Stone Inc. averages $5,654 (1 cited inspection).

Tracery Stone Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

99employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Tracery Stone Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343382602 OPENED AUG 13, 2018Closed

Complaint · Partial · Safety · 23 employees at the site · Closed Nov 9, 2018

108 28th Street North, Birmingham, AL 35203 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$3,769$2,261Oct 23, 2018Final
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$3,769$2,261Oct 23, 2018Final
Citation 1, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,885$1,131Oct 23, 2018Final
Citation 2, item 1
29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry
Other-than-serious$0$0Oct 23, 2018Final
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Oct 23, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(11)(ii)

(ii) Each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows:

29 CFR 1910.305 · Electrical wiring methods

Other cut stone and stone product manufacturing employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.