Inspection 342968237 OPENED FEB 21, 2018Closed
1020 E 19th St N, Wichita, KS 67214 · Conveyor and Conveying Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Feb 12, 2018: Employee amputates fingers in press brake
At 8:10 a.m. on February 12, 2018, an employee was using a hydraulic press brake, Model Number 350 PFT10, Serial Number 55270, while bending a section of metal that was 3 foot by 2 inches wide. The employee pinched two fingers on his left hand and amputated both fingers. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $6,596 | $4,617 | May 1, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $3,298 | $2,309 | May 1, 2018 | Final |
| Citation 1, item 3a 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $3,298 | $2,309 | May 1, 2018 | Final |
| Citation 1, item 3b 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | May 1, 2018 | Final |