OSHA SearchOSHA records by employer

Tru-Fab Technology Inc.: OSHA inspections and violations

Eastlake, Ohio · Powder Metallurgy Part Manufacturing · NAICS 332117

3inspections
24citation items
$2,600current penalties
Jan 13, 2017last inspection

Since 2009, OSHA inspectors have visited Tru-Fab Technology Inc. in Ohio 3 times.

The most recent inspection opened on Jan 13, 2017 as a planned inspection, in Eastlake.

In all, OSHA issued 24 citation items: 14 serious and 10 other-than-serious.

The proposed penalties came to $4,550; today they stand at $2,600, 43% less.

The rule cited most here is 1910.107 (spray painting and finishing), 9 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Tru-Fab Technology Inc. averages $0 across 1 cited inspection.

Tru-Fab Technology Inc.: OSHA citation items per year, 2009 to 2017
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Tru-Fab Technology Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342027703 OPENED JAN 13, 2017Closed

Planned · Partial · Safety · 35 employees at the site · Closed Mar 9, 2017

34820 Lakeland Blvd, Eastlake, OH 44095 · Powder Metallurgy Part Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Other-than-serious$0$0Feb 3, 2017Final
Citation 1, item 1b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Other-than-serious$0$0Feb 3, 2017Final
Citation 1, item 1c
29 CFR 1910.179(n)(4)(i) · Overhead and gantry cranes
Other-than-serious$0$0Feb 3, 2017Final

Inspection 313561169 OPENED JUL 7, 2009Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Feb 1, 2010

34820 Lakeland Blvd, Eastlake, OH 44095 · Powder Metallurgy Part Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$700$400Nov 5, 2009Closed
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$700$400Nov 5, 2009Closed
Citation 2, item 1
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Nov 5, 2009Closed

Inspection 313561185 OPENED JUL 7, 2009Closed

Complaint · Partial · Health · 35 employees at the site · Closed Feb 19, 2010

34820 Lakeland Blvd, Eastlake, OH 44095 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$525$300Nov 5, 2009Closed
Citation 1, item 2
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$525$300Nov 5, 2009Closed
Citation 1, item 3a
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$525$300Nov 5, 2009Closed
Citation 1, item 3b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Nov 5, 2009Closed
Citation 1, item 3c
29 CFR 1910.107(g)(5) · Spray painting and finishing
Serious$0$0Nov 5, 2009Closed
Citation 1, item 3d
29 CFR 1910.107(g)(3) · Spray painting and finishing
Serious$0$0Nov 5, 2009Closed
Citation 1, item 4a
29 CFR 1910.107(c)(8) · Spray painting and finishing
Serious$525$300Nov 5, 2009Closed
Citation 1, item 4b
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0Nov 5, 2009Closed
Citation 1, item 4c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Nov 5, 2009Closed
Citation 1, item 5
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$525$300Nov 5, 2009Closed
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$525$300Nov 5, 2009Closed
Citation 1, item 6b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Nov 5, 2009Closed
Citation 2, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 2a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 2b
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 2c
29 CFR 1910.133(a)(3) · Eye and face protection
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 2d
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 5, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.37 · Exit routes

Other powder metallurgy part manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.