OSHA SearchOSHA records by employer

Tucker Construction & Engineering, Inc.: OSHA inspections and violations

Auburndale, Florida · Structural Steel and Precast Concrete Contractors · NAICS 238120

8inspections
16citation items
$24,499current penalties
Nov 9, 2018last inspection

Tucker Construction & Engineering, Inc. has 8 OSHA inspections on record in Florida, the first in 1986.

OSHA's last visit started on Nov 9, 2018 on a referral, in Orlando.

Across those inspections OSHA issued 16 citation items: 14 serious and 2 other-than-serious.

OSHA proposed $40,314 in penalties. After settlements and reviews the total is $24,499, down 39%.

Most often, OSHA cited 1926.550, [reserved] (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Tucker Construction & Engineering, Inc. averages $5,100 over 2 cited inspections in that time.

2 inspections on this page followed a fatal incident.

It reported 2 severe injuries to OSHA since 2015.

Tucker Construction & Engineering, Inc.: OSHA citation items per year, 1986 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Tucker Construction & Engineering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343600821 OPENED NOV 9, 2018Closed

Referral · Partial · Safety · 5 employees at the site · Closed May 28, 2019

3479 W. Washington St, Orlando, FL 32805 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Nov 5, 2018: Employee sustains several fractures and lacerations in fall

At 2:45 p.m. on November 5, 2018, an employee was tossing tree branches down for disposal as his coworkers cut them. The employee stepped through a hidden skylight that was covered by leaves, grass, and debris, falling approximately 15 feet and fractured several ribs, lacerated his liver, and fractured his wrist. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.754(e)(3)(i) · Structural steel assembly
Serious$5,834$5,834Apr 30, 2019Final

Inspection 341362168 OPENED MAR 28, 2016Closed

Referral · Partial · Safety · 6 employees at the site · Closed Sep 16, 2016

2792 Saddle Creek Road Saddle Creek Warehouse #2, Lakeland, FL 33801 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$8,730$4,365Aug 10, 2016Final

Inspection 309674216 OPENED JAN 5, 2006Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Jan 5, 2006

3900 Avenue G Nw, Winter Haven, FL 33880 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109676510 OPENED APR 3, 1997Closed

Planned · No inspection · Safety · Closed Apr 7, 1997

625 Overlook Drive, Winter Haven, FL 33880 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 116450461 OPENED OCT 9, 1996Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 22, 1996

302 Progress Rd, Auburndale, FL 33823 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110133188 OPENED MAY 26, 1993Closed

Accident · Complete · Safety · 12 employees at the site · Closed Dec 3, 1993

1707 Huron Street, Jacksonville, FL 32205 · OSHA's record · Phone and website on Google Maps

Incident on May 25, 1993 (fatal): Employee killed in fall through roof insulation

On May 26, 1993, Employee #1, who was without fall protection, was working on a roof top with a coworker. They were carrying 24 ft 7 in. by 3 ft sheet metal pan els to two sheet metal erectors who would be installing them on the roof. Employ ee #1 would hold one end of the panel and the coworker the other end. They would give the panel to the erectors, step back, and return with another panel. At ap proximately 10:30 a.m., the coworker gave his end to his erector, but Employee # 1 did not release his end. Employee #1's erector grabbed the panel because Emplo yee #1 did not stop. Instead, he continued walking straight ahead and fell throu gh the insulation, falling 32 ft and landing on the concrete floor. Employee #1 died.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.105(a) · Safety nets
Serious$4,200$2,800Aug 26, 1993Closed
Citation 1, item 2
29 CFR 1926.350(j) · Gas welding and cutting
Other-than-serious$900$0Aug 26, 1993Closed
Citation 1, item 3
29 CFR 1926.500(b)(4) · Scope, application, and definitions applicable to this subpart
Serious$4,200$2,700Aug 26, 1993Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,200$800Aug 26, 1993Closed

Inspection 106388242 OPENED AUG 22, 1991Closed

Unprogrammed related · Complete · Safety · 10 employees at the site · Closed Nov 25, 1991

203 Alexander Street, Plant City, FL 33567 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,500$500Oct 17, 1991Closed
Citation 1, item 2
29 CFR 1926.451(a)(3) · Scaffolds, general requirements
Serious$750$500Oct 17, 1991Closed
Citation 1, item 3
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$1,750$500Oct 17, 1991Closed
Citation 1, item 4
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$1,750$500Oct 17, 1991Closed
Citation 1, item 5
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,750$500Oct 17, 1991Closed
Citation 1, item 6a
29 CFR 1926.550(a)(5) · [Reserved]
Serious$2,500$1,250Oct 17, 1991Closed
Citation 1, item 6b Serious$0$0Oct 17, 1991Closed
Citation 1, item 7 Serious$2,500$2,500Oct 17, 1991Closed
Citation 1, item 8
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,750$1,750Oct 17, 1991Closed
Citation 2, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Oct 17, 1991Closed

Inspection 101830941 OPENED MAY 22, 1986Closed

Accident · Complete · Safety · 10 employees at the site · Closed Aug 5, 1986

940 Derby Ave., Auburndale, FL 33823 · OSHA's record · Phone and website on Google Maps

Incident on May 19, 1986 (fatal): Fall from 30 ft

AN EMPLOYEE WAS INSTALLING INSULATION AND STEEL (CORRUGATED) PIECES ON A ROOF, 3 30 X 220 AND 34 FEET IN CENTER AND 24 AT EDGES. HE WAS TAPING THE INSULATION TO THE STEEL PURLINS, WHEN HE EVIDENTLY SLIPPED AND FEEL SOME 30 FEET TO THE CONCRE TE FLOOR. HE WAS EXPERIENCED AT WHAT HE WAS DOING AND THIS WAS HIS NORMAL DUTY.

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Nov 5, 2018, Orlando: Hospitalization · internal injuries to organs and blood vessels of the trunk · abdomen, except internal location of diseases or disorders

While removing a tree branch from the edge of a one-story-high roof, an employee fell through a skylight to the concrete floor. The employee suffered fractured ribs, a lacerated liver, and a broken wrist.

Mar 7, 2016, Lakeland: Hospitalization · fractures · leg(s), unspecified

While replacing roof sheet metal, an employee fell approximately 26 feet from the roof, to the top of a forklift, and then to the concrete ground, suffering a broken leg.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1926.105 · Safety nets

29 CFR 1926.105(a)

(a) Safety nets shall be provided when workplaces are more than 25 feet above the ground or water surface, or other surfaces where the use of ladders, scaffolds, catch platforms, temporary floors, safety lines, or safety belts is impractical.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.550 · [Reserved]

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.754 · Structural steel assembly

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.