Wolcott, New York · Commercial and Institutional Building Construction · NAICS 236220

16inspections
27citation items
$10,192current penalties
Jun 23, 2021last inspection

OSHA has inspected Two Plus Four Construction Co., Inc. 16 times in New York since 1990.

The latest one began on Jun 23, 2021 as a planned inspection, in Pulaski.

Those inspections ended with 27 citation items: 18 serious, 1 repeat and 8 other-than-serious.

Penalties were first proposed at $14,239 and now stand at $10,192, 28% lower after settlements or reviews.

Fire protection comes up most often in these citations: 4 items under 1926.150.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Two Plus Four Construction Co., Inc. averages $2,842 (1 cited inspection).

Two Plus Four Construction Co., Inc.: OSHA citation items per year, 1990 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Two Plus Four Construction Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345381073 OPENED JUN 23, 2021Closed

Planned · Partial · Safety · 15 employees at the site · Closed Oct 25, 2021

Selkirk Landing 4625 Salina Street (route 11), Pulaski, NY 13142 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344204987 OPENED AUG 1, 2019Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 30, 2019

23-25 North Main Street, Wellsville, NY 14895 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$3,789$2,842Sep 19, 2019Final

Inspection 342794997 OPENED NOV 28, 2017Closed

Complaint · Complete · Safety · 3 employees at the site · Closed Nov 28, 2017

217 Genesee St, Auburn, NY 13021 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 338189038 OPENED JAN 8, 2013Closed

Planned · Partial · Safety · 13 employees at the site · Closed Apr 30, 2013

20 Paul Raihofer Blvd., Valatie, NY 12184 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,000$1,200Mar 26, 2013Final
Citation 1, item 2
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$2,000$1,200Mar 26, 2013Final
Citation 1, item 3
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$1,200$750Mar 26, 2013Final
Citation 2, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Mar 26, 2013Final

Inspection 310524434 OPENED DEC 20, 2007Closed

Planned · Complete · Safety · 6 employees at the site · Closed Dec 20, 2007

100 Harry Howard Ave., Hudson, NY 12534 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309379014 OPENED FEB 9, 2006Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 25, 2006

Stony Brook Apartments, Stony Brook Road, Verona, NY 13478 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$750$750Mar 29, 2006Closed
Citation 1, item 1b
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$0$0Mar 29, 2006Closed

Inspection 309378917 OPENED FEB 8, 2006Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 30, 2006

Connelly Acres Apartments, Maple Road, Camillus, NY 13031 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.150(c)(1)(iv) · Fire protection
Serious$450$270Feb 14, 2006Closed
Citation 1, item 1b
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$0$0Feb 14, 2006Closed
Citation 1, item 2
29 CFR 1926.300(a) · Tools—Hand and Power: general requirements
Serious$450$270Feb 14, 2006Closed
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$360Feb 14, 2006Closed
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Feb 14, 2006Closed

Inspection 304467145 OPENED MAY 23, 2002Closed

Planned · Partial · Safety · 1 employee at the site · Closed May 28, 2002

2415 Curry Rd., Schenectady, NY 12303 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

8 older inspections

Inspection 304463458 OPENED DEC 26, 2001Closed

Planned · Complete · Safety · 2 employees at the site · Closed Feb 5, 2002

183 Barnerville Rd., Cobleskill, NY 12043 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.153(o) · Liquefied petroleum gas (LP-Gas)
Serious$600$600Jan 4, 2002Closed
Citation 2, item 1
29 CFR 1926.150(c)(1)(iv) · Fire protection
Repeat$0$0Jan 4, 2002Closed
Citation 3, item 1
29 CFR 1926.1052(c)(1) · Stairways in construction
Other-than-serious$0$0Jan 4, 2002Closed

Inspection 304459837 OPENED MAY 16, 2001Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 22, 2001

Rte 17k And Ward Street, Montgomery, NY 12549 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302690938 OPENED MAY 25, 2000Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Jul 14, 2000

Prospect Hills Apartments, 24 Johnston St., Seneca Falls, NY 13148 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(iv) · Fire protection
Other-than-serious$0$0Jun 1, 2000Closed

Inspection 302690268 OPENED MAR 20, 2000Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 22, 2000

Sidney Apartments, 500 Circle Drive, Sidney, NY 13838 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 17672312 OPENED JUN 12, 1997Closed

Planned · Complete · Safety · 2 employees at the site · Closed Aug 19, 1997

62 Grove St., Windsor, NY 13865 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Jul 15, 1997Closed

Inspection 109038885 OPENED MAR 25, 1993Closed

Referral · Complete · Safety · 3 employees at the site · Closed Jun 4, 1993

New Scotland Rd., Feura Bush, NY 12067 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.153(j) · Liquefied petroleum gas (LP-Gas)
Serious$750$400Apr 19, 1993Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$300$200Apr 19, 1993Closed
Citation 2, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Apr 19, 1993Closed
Citation 2, item 3
29 CFR 1926.153(l) · Liquefied petroleum gas (LP-Gas)
Other-than-serious$0$0Apr 19, 1993Closed
Citation 2, item 4
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Other-than-serious$0$0Apr 19, 1993Closed

Inspection 18151498 OPENED MAR 5, 1991Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 14, 1991

Cooper Street, Oriskany Falls, NY 13425 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 18152538 OPENED FEB 9, 1990Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jul 12, 1990

95 New Hartford Street, Wolcott, NY 14590 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$250$250Mar 9, 1990Closed
Citation 1, item 2
29 CFR 1926.59(g)(8) · Hazard communication
Serious$250$250Mar 9, 1990Closed
Citation 1, item 3
29 CFR 1926.59(h) · Hazard communication
Serious$250$250Mar 9, 1990Closed
Citation 1, item 4
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Serious$250$250Mar 9, 1990Closed
Citation 1, item 5
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$350$350Mar 9, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.150 · Fire protection

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.25 · Housekeeping

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.59 · Hazard communication

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.