OSHA SearchOSHA records by employer

Utah Steel Inc.: OSHA inspections and violations

Salt Lake City, Utah · Fabricated Structural Metal Manufacturing · NAICS 332312

3inspections
29citation items
$3,375current penalties
May 25, 2018last inspection

Since 1998, OSHA inspectors have visited Utah Steel Inc. in Utah 3 times.

The most recent inspection opened on May 25, 2018 as a planned inspection, in Salt Lake City.

In all, OSHA issued 29 citation items: 4 serious and 25 other-than-serious.

The proposed penalties came to $3,750; today they stand at $3,375, 10% less.

The rule cited most here is 1910.179 (overhead and gantry cranes), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Utah Steel Inc. averages $375 across 1 cited inspection.

Utah Steel Inc.: OSHA citation items per year, 1998 to 2018
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Utah Steel Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343191078 OPENED MAY 25, 2018Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 13, 2018

568 South Redwood Road, Salt Lake City, UT 84104 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$750$375Jun 12, 2018Final
Citation 1, item 1b
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$0$0Jun 12, 2018Final

Inspection 126794742 OPENED OCT 28, 1998Closed

Planned · Complete · Health · 21 employees at the site · Closed Jun 2, 1999

006 S. Orange St., Salt Lake City, UT 84116 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,500$1,500Nov 12, 1998Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,500$1,500Nov 12, 1998Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 2
29 CFR 1910.26(c)(2)(vii) · Portable metal ladders
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 4
29 CFR 1910.107(c)(2) · Spray painting and finishing
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 5
29 CFR 1910.132(d)(1)(i) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 6
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 7
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 8
29 CFR 1910.141(d)(1) · Sanitation
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 9
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 10
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 11
29 CFR 1910.179(g)(2)(i) · Overhead and gantry cranes
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 12
29 CFR 1910.179(j)(2) · Overhead and gantry cranes
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 13
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 14
29 CFR 1910.179(j)(3)(iiid) · Overhead and gantry cranes
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 15
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 16 Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 17
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 18
29 CFR 1910.215(d)(1) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 19
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 20
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 21
29 CFR 1910.303(g)(2)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 22
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 23
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 24
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Nov 12, 1998Closed
Citation 2, item 25
29 CFR 1910.1200(f)(5) · Hazard communication
Other-than-serious$0$0Nov 12, 1998Closed

Inspection 126783620 OPENED FEB 4, 1998Closed

Planned · No inspection · Safety · Closed Feb 4, 1998

1025 W 1200 N, Salt Lake City, UT 84116 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.26 · Portable metal ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other fabricated structural metal manufacturing employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.