OSHA SearchOSHA records by employer

Valley Storm Shelters, LLC: OSHA inspections and violations

Scottsboro, Alabama · All Other Miscellaneous Manufacturing · NAICS 339999

2inspections
10citation items
$1,680current penalties
Sep 22, 2015last inspection

Since 2015, OSHA inspectors have visited Valley Storm Shelters, LLC in Alabama 2 times.

The most recent inspection opened on Sep 22, 2015 after a complaint, in Scottsboro.

In all, OSHA issued 10 citation items: 6 serious and 4 other-than-serious.

The proposed penalties came to $2,800; today they stand at $1,680, 40% less.

The rule cited most here is 1910.107 (spray painting and finishing), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Valley Storm Shelters, LLC averages $840 across 2 cited inspections.

Valley Storm Shelters, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

95employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Valley Storm Shelters, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340942879 OPENED SEP 22, 2015Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Feb 9, 2016

14628 Us Highway 72, Scottsboro, AL 35768 · All Other Miscellaneous Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Jan 6, 2016Final
Citation 1, item 2
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Jan 6, 2016Final

Inspection 340946326 OPENED SEP 22, 2015Closed

Complaint · Partial · Health · 8 employees at the site · Closed Mar 16, 2016

14628 Us Highway 72, Scottsboro, AL 35768 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,600$960Jan 12, 2016Final
Citation 1, item 2a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$1,200$720Jan 12, 2016Final
Citation 1, item 2b
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jan 12, 2016Final
Citation 1, item 2c
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Jan 12, 2016Final
Citation 1, item 2d
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$0$0Jan 12, 2016Final
Citation 1, item 2e
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Jan 12, 2016Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Jan 12, 2016Final
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 12, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.22 · General requirements

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other all other miscellaneous manufacturing employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.