OSHA SearchOSHA records by employer

Van Rite & Father, Inc.: OSHA inspections and violations

Green Bay, Wisconsin · Residential Remodelers · NAICS 236118

3inspections
15citation items
$9,999current penalties
Mar 19, 2019last inspection

OSHA has inspected Van Rite & Father, Inc. 3 times in Wisconsin since 2009.

The latest one began on Mar 19, 2019 on a referral, in De Pere.

Those inspections ended with 15 citation items: 9 serious and 6 other-than-serious.

Penalties were first proposed at $18,976 and now stand at $9,999, 47% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Van Rite & Father, Inc. averages $7,899 (1 cited inspection).

Van Rite & Father, Inc.: OSHA citation items per year, 2009 to 2019
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Van Rite & Father, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343861621 OPENED MAR 19, 2019Closed

Referral · Partial · Safety · 6 employees at the site · Closed Dec 17, 2019

1680 Mid Valley Rd., De Pere, WI 54115 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 19, 2019: Employee is struck by collapsing trusses and receives multip

At 12:00 a.m. on March 19, 2019, an employee operated a telehandler with a man-basket, which contained two coworkers. The coworkers were correcting an improperly installed brace to one of the trusses. At some point, the employee left the telehandler to retrieve a level for the coworkers when the trusses collapsed and fell on top of the employee. The employee was hospitalized to treat two rib fractures, puncture to large intestine (cecum), and an unspecified knee injury.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,978$3,978May 17, 2019Final
Citation 1, item 2
29 CFR 1926.28(a) · Personal protective equipment
Other-than-serious$3,410$1,705May 17, 2019Final
Citation 1, item 3a
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Other-than-serious$3,410$1,023May 17, 2019Final
Citation 1, item 3b
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0May 17, 2019Final
Citation 1, item 4
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$3,978$1,193May 17, 2019Final

Inspection 339120610 OPENED JUN 19, 2013Closed

Complaint · Partial · Health · 3 employees at the site · Closed Sep 26, 2013

706 Main Street, Luxemburg, WI 54217 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.62(d)(1)(i) · Lead in construction
Other-than-serious$0$0Aug 20, 2013Final
Citation 1, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Aug 20, 2013Final

Inspection 312551088 OPENED FEB 12, 2009Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 2, 2009

1860 University Avenue, Green Bay, WI 54302 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$600$300Mar 10, 2009Closed
Citation 1, item 2
29 CFR 1926.304(f) · Woodworking tools
Serious$1,050$525Mar 10, 2009Closed
Citation 1, item 3
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$1,050$525Mar 10, 2009Closed
Citation 1, item 4a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$750Mar 10, 2009Closed
Citation 1, item 4b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Mar 10, 2009Closed
Citation 1, item 4c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Mar 10, 2009Closed
Citation 1, item 4d
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Mar 10, 2009Closed
Citation 1, item 4e
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$0$0Mar 10, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(a)(5)

(5) If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.62 · Lead in construction

OSH Act Section 5 · General Duty Clause

Other residential remodelers employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.