OSHA SearchOSHA records by employer

Van's Lumber & Custom Builders Inc: OSHA inspections and violations

Sister Bay, Wisconsin · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

4inspections
14citation items
$17,243current penalties
Apr 11, 2018last inspection

Since 2010, OSHA inspectors have visited Van's Lumber & Custom Builders Inc in Wisconsin 4 times.

The most recent inspection opened on Apr 11, 2018 as a planned inspection, in Egg Harbor.

In all, OSHA issued 14 citation items: 12 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $31,809; today they stand at $17,243, 46% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 9 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Van's Lumber & Custom Builders Inc averages $4,498 across 3 cited inspections.

Van's Lumber & Custom Builders Inc: OSHA citation items per year, 2010 to 2018
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

218employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Van's Lumber & Custom Builders Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343083796 OPENED APR 11, 2018Closed

Planned · Partial · Safety · 35 employees at the site · Closed Apr 24, 2019

7791 Wi 42, Egg Harbor, WI 54209 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$9,054$4,527Jun 26, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jun 26, 2018Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$12,935$6,467Jun 26, 2018Final

Inspection 341571867 OPENED JUN 23, 2016Closed

Planned · Partial · Safety · 70 employees at the site · Closed Aug 3, 2016

3530 Mayapple Dr., Green Bay, WI 54311 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$595$416Jul 22, 2016Final

Inspection 341382208 OPENED APR 7, 2016Closed

Planned · Partial · Safety · 25 employees at the site · Closed Apr 28, 2016

5274 Bayshore Dr., Sturgeon Bay, WI 54235 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,975$2,082Apr 12, 2016Final

Inspection 312557606 OPENED JUL 14, 2010Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 18, 2010

966 Bayshore Drive, Sister Bay, WI 54234 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,500$1,500Aug 23, 2010Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 23, 2010Closed
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Aug 23, 2010Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,500$1,500Aug 23, 2010Closed
Citation 1, item 2b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 23, 2010Closed
Citation 1, item 2c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 23, 2010Closed
Citation 1, item 2d
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Aug 23, 2010Closed
Citation 1, item 2e
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Aug 23, 2010Closed
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,250$750Aug 23, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(1)(ii)

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.