OSHA SearchOSHA records by employer

Viesko Redi-Mix Inc: OSHA inspections and violations

Gervais, Oregon · Ready-Mix Concrete Manufacturing · NAICS 327320

8inspections
49citation items
$2,975current penalties
Jul 29, 2015last inspection

Since 1985, OSHA inspectors have visited Viesko Redi-Mix Inc in Oregon 8 times.

The most recent inspection opened on Jul 29, 2015 after a complaint, in Woodburn.

In all, OSHA issued 49 citation items: 12 serious and 37 other-than-serious.

The penalties, $2,975 in total, stand where OSHA first set them.

The rule cited most here is 7010.7650 (), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Viesko Redi-Mix Inc averages $550 across 1 cited inspection.

Viesko Redi-Mix Inc: OSHA citation items per year, 1985 to 2015
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

397employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Viesko Redi-Mix Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340908755 OPENED JUL 29, 2015Closed

Complaint · Partial · Health · 4 employees at the site · Closed Jan 26, 2016

16538 Arney Rd Ne, Woodburn, OR 97071 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$150$150Sep 15, 2015Final
Citation 1, item 2a
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$250$250Sep 15, 2015Final
Citation 1, item 2b Serious$0$0Sep 15, 2015Final
Citation 1, item 3
29 CFR OAR 437-002-0107(3)(G)(C)
Serious$150$150Sep 15, 2015Final
Citation 2, item 4
29 CFR OAR 437-002-0107(3)(H)(K)-1
Other-than-serious$0$0Sep 15, 2015Final
Citation 2, item 5
29 CFR OAR 437-002-0107(3)(H)(C)(IV)
Other-than-serious$0$0Sep 15, 2015Final

Inspection 302680350 OPENED JUN 28, 1999Closed

Accident · No inspection · Safety · 39 employees at the site · Closed Jun 28, 1999

741 Matheny Road Ne, Gervais, OR 97026 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302678693 OPENED MAY 20, 1999Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 23, 2005

16538 Arney Rd Ne, Woodburn, OR 97071 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$625$625Jun 11, 1999Closed
Citation 1, item 2a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$325$325Jun 11, 1999Closed
Citation 1, item 2b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Jun 11, 1999Closed
Citation 1, item 2c Serious$0$0Jun 11, 1999Closed
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$325$325Jun 11, 1999Closed
Citation 2, item 4
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Jun 11, 1999Closed
Citation 2, item 5 Other-than-serious$0$0Jun 11, 1999Closed

Inspection 302051057 OPENED OCT 14, 1998Closed

Planned · Complete · Safety · 47 employees at the site · Closed Sep 8, 1999

741 Matheny Rd Ne, Gervais, OR 97026 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$105$105Dec 7, 1998Closed
Citation 2, item 2 Other-than-serious$195$195Dec 7, 1998Closed
Citation 2, item 3 Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 4 Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 5 Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 6
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 7
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 7, 1998Closed

Inspection 126703537 OPENED OCT 23, 1995Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 29, 1996

16538 Arney Rd Ne, Woodburn, OR 97071 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$100$100Dec 4, 1995Closed
Citation 2, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Dec 4, 1995Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Dec 4, 1995Closed
Citation 2, item 4
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Dec 4, 1995Closed
Citation 2, item 5 Other-than-serious$0$0Dec 4, 1995Closed
Citation 2, item 6 Other-than-serious$0$0Dec 4, 1995Closed
Citation 2, item 7 Other-than-serious$0$0Dec 4, 1995Closed

Inspection 123743593 OPENED JUL 8, 1993Closed

Planned · No inspection · Safety · Closed Jul 8, 1993

8076 River Rd Ne, Salem, OR 97303 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 115697955 OPENED OCT 1, 1991Closed

Planned · Complete · Safety · 40 employees at the site · Closed Feb 10, 1992

741 Matheny Rd Ne, Gervais, OR 97026 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$150$150Dec 4, 1991Closed
Citation 2, item 2
29 CFR 1910.213(c)(2) · Woodworking machinery
Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 3
29 CFR 1910.213(c)(3) · Woodworking machinery
Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 4
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 6 Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 7 Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 8
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 9
29 CFR 1910.305(a)(2)(iiif) · Electrical wiring methods
Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 11
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 12 Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 13
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 14 Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 15
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 16 Other-than-serious$0$0Dec 4, 1991Closed
Citation 2, item 17a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$75$75Dec 4, 1991Closed
Citation 2, item 17b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 4, 1991Closed

Inspection 15035405 OPENED JAN 31, 1985Closed

Planned · Complete · Safety · 20 employees at the site · Closed Apr 19, 1985

741 Methany Rd Ne, Gervais, OR 97026 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 13, 1985Closed
Citation 1, item 2 Other-than-serious$0$0Feb 13, 1985Closed
Citation 1, item 3
29 CFR 7110001G401
Other-than-serious$0$0Feb 13, 1985Closed
Citation 1, item 4 Other-than-serious$0$0Feb 13, 1985Closed
Citation 1, item 5 Other-than-serious$0$0Feb 13, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.1027 · Cadmium

29 CFR 1910.1027(k)(1)

(k) Housekeeping. (1) All surfaces shall be maintained as free as practicable of accumulations of cadmium.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7650

29 CFR 7020.1610

29 CFR 7020.2231

29 CFR 7020.2420

29 CFR 7020.2900

29 CFR 7400.400

29 CFR 7400.450

29 CFR 7400.470

29 CFR 7400.700

29 CFR 7600.311

29 CFR 7670.2750

Other ready-mix concrete manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.