Since 1977, OSHA inspectors have visited Warwick Mills, Inc. in New Hampshire 8 times.
The most recent inspection opened on Nov 14, 2016 after a complaint, in New Ipswich.
In all, OSHA issued 30 citation items: 15 serious and 15 other-than-serious.
The proposed penalties came to $21,750; today they stand at $13,575, 38% less.
The rule cited most here is 1910.107 (spray painting and finishing), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. Warwick Mills, Inc. averages $0 across 1 cited inspection.
Warwick Mills, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New Hampshire · latest 90 days of OSHA records
53employers cited
Get notified the morning OSHA posts each new citation in New Hampshire: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the New Ipswich site logged 3 recordable injuries or illnesses among about 52 workers: 5.9 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 7 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Warwick Mills Inc.
New Ipswich · 2025
52
3
2
5.9
2.6
Included with any plan: 5 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(3) Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
29 CFR 1910.120 · Hazardous waste operations and emergency response
Alert subscribers get notified of each newly cited employer in New Hampshire the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.