OSHA SearchOSHA records by employer

Watts Regulator Co.: OSHA inspections and violations

Spindale, North Carolina · Nonferrous Metal Foundries · NAICS 331525

10inspections
29citation items
$6,730current penalties
Mar 31, 2015last inspection

Watts Regulator Co. has 10 OSHA inspections on record in North Carolina, the first in 2000.

OSHA's last visit started on Mar 31, 2015 as a planned inspection, in Spindale.

Across those inspections OSHA issued 29 citation items: 14 serious and 15 other-than-serious.

OSHA proposed $9,900 in penalties. After settlements and reviews the total is $6,730, down 32%.

Most often, OSHA cited 1910.1025, lead in general industry (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Watts Regulator Co. averages $1,200 over 1 cited inspection in that time.

Watts Regulator Co. also files yearly injury logs with OSHA, summarized below.

Watts Regulator Co.: OSHA citation items per year, 2000 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

237employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Watts Regulator Co. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317983187 OPENED MAR 31, 2015Closed

Planned · Complete · Health · 100 employees at the site · Closed May 22, 2015

100 Watts Road, Spindale, NC 28160 · Plumbing and Heating Equipment and Supplies (Hydronics) Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,200$1,200Apr 27, 2015Closed
Citation 1, item 1b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Apr 27, 2015Closed
Citation 2, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Apr 27, 2015Closed

Inspection 312533706 OPENED NOV 4, 2008Closed

Planned · Complete · Safety · 300 employees at the site · Closed Dec 18, 2008

100 Watts Road, Spindale, NC 28160 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,375$688Dec 1, 2008Closed
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 1, 2008Closed

Inspection 312815525 OPENED NOV 4, 2008Closed

Planned · Complete · Health · 300 employees at the site · Closed Dec 18, 2008

100 Watts Road, Spindale, NC 28160 · Industrial Valve Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$962$604Dec 1, 2008Closed
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,925$1,155Dec 1, 2008Closed
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 1, 2008Closed
Citation 2, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Dec 1, 2008Closed

Inspection 308555804 OPENED APR 6, 2005Closed

Planned · Complete · Health · 300 employees at the site · Closed Oct 1, 2005

100 Watts Road, Spindale, NC 28160 · Other Metal Valve and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(7)(i) · Flammable liquids
Other-than-serious$0$0May 26, 2005Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0May 26, 2005Closed

Inspection 308724905 OPENED APR 6, 2005Closed

Planned · Complete · Safety · 300 employees at the site · Closed Jun 14, 2005

100 Watts Road, Spindale, NC 28160 · Other Metal Valve and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$813$528Apr 25, 2005Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,625$1,056Apr 25, 2005Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Apr 25, 2005Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Apr 25, 2005Closed
Citation 2, item 3
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Apr 25, 2005Closed
Citation 2, item 4
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Apr 25, 2005Closed
Citation 2, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Apr 25, 2005Closed
Citation 2, item 6
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 25, 2005Closed
Citation 2, item 7
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 25, 2005Closed

Inspection 307048850 OPENED OCT 9, 2003Closed

Referral · Partial · Health · 60 employees at the site · Closed Jan 29, 2004

100 Watts Road, Spindale, NC 28160 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1025(c)(1) · Lead in general industry
Serious$1,000$750Nov 17, 2003Closed
Citation 1, item 1b
29 CFR 1910.1025(e)(1) · Lead in general industry
Serious$0$0Nov 17, 2003Closed
Citation 1, item 1c
29 CFR 1910.1025(g)(1)(i) · Lead in general industry
Serious$0$0Nov 17, 2003Closed
Citation 1, item 1d
29 CFR 1910.134(h)(1) · Respiratory protection
Serious$0$0Nov 17, 2003Closed
Citation 1, item 2a
29 CFR 1910.1025(d)(7) · Lead in general industry
Serious$1,000$750Nov 17, 2003Closed
Citation 1, item 2b
29 CFR 1910.1025(j)(2)(ib) · Lead in general industry
Serious$0$0Nov 17, 2003Closed
Citation 1, item 2c
29 CFR 1910.1025(j)(3)(ia) · Lead in general industry
Serious$0$0Nov 17, 2003Closed

Inspection 306882499 OPENED JUL 10, 2003Closed

Complaint · Partial · Health · 85 employees at the site · Closed Jul 25, 2003

100 Watts Road, Spindale, NC 28160 · Nonferrous Metal Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306253725 OPENED FEB 5, 2003Closed

Complaint · Partial · Safety · 450 employees at the site · Closed Feb 25, 2003

100 Watts Road, Spindale, NC 28160 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 6, 2003: Employee's finger amputated in power press

An employee was operating a power press and she disconnected her wristlets from the pull back device. The press repeated while she had her hand in the machine. As a result, one of her fingers was amputated.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(b)(1) · General requirements
Other-than-serious$0$0Feb 14, 2003Closed
2 older inspections

Inspection 304599905 OPENED JUN 5, 2001Closed

Complaint · Partial · Safety · 150 employees at the site · Closed Jul 9, 2001

100 Watts Rd., Spindale, NC 28160 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.135(a)(1) · Head protection
Other-than-serious$0$0Jul 2, 2001Closed

Inspection 303834774 OPENED JUL 26, 2000Closed

Complaint · Partial · Safety · 150 employees at the site · Closed Jul 28, 2000

100 Watts Rd., Spindale, NC 28160 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Spindale site logged 0 recordable injuries or illnesses among about 50 workers: 0.0 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Watts - Spindale
Spindale · 2025
50 000.02.6
Watts Regulator
Spindale · 2016
80 101.42.6

Included with any plan: 2 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(c)(1)

(c) Permissible exposure limit (PEL). (1) The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 µg/m 3) averaged over an 8-hour period.

29 CFR 1910.1025(d)(7)

(7) Additional monitoring. Whenever there has been a production, process, control or personnel change which may result in new or additional exposure to lead, or whenever the employer has any other reason to suspect a change which may result in new or additional exposures to lead, additional monitoring in accordance with this paragraph shall be conducted.

29 CFR 1910.1025(g)(1)(i)

(i) Coveralls or similar full-body work clothing;

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.135 · Head protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other nonferrous metal foundries employers in North Carolina