Inspection 348693136 OPENED JAN 13, 2026Closed
3623 Independence Dr., Fort Wayne, IN 46808 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Fort Wayne, Indiana · Heating Equipment (except Warm Air Furnaces) Manufacturing · NAICS 333414
OSHA has inspected Wayne Combustion Systems 4 times in Indiana since 2003.
The latest one began on Jan 13, 2026 after a complaint, in Fort Wayne.
Those inspections ended with 29 citation items: 9 serious and 20 other-than-serious.
Penalties were first proposed at $12,875 and now stand at $4,289, 67% lower after settlements or reviews.
Mechanical power presses comes up most often in these citations: 5 items under 1910.217.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Wayne Combustion Systems averages $878 (1 cited inspection).
Wayne Combustion Systems also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Wayne Combustion Systems again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company3623 Independence Dr., Fort Wayne, IN 46808 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
801 Glasgow Ave, Fort Wayne, IN 46803 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $1,350 | $878 | Nov 29, 2022 | Final |
801 Glasgow Ave., Fort Wayne, IN 46803 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(4) · Exit routes |
Serious | $525 | $341 | Nov 7, 2014 | Closed |
801 Glasgow Ave., Fort Wayne, IN 46803 · Pump and Compressor Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $1,000 | $525 | Jan 13, 2004 | Closed |
| Citation 1, item 2 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Other-than-serious | $1,000 | $0 | Jan 13, 2004 | Closed |
| Citation 1, item 3 29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes |
Other-than-serious | $750 | $0 | Jan 13, 2004 | Closed |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $1,000 | $350 | Jan 13, 2004 | Closed |
| Citation 1, item 5 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $1,000 | $0 | Jan 13, 2004 | Closed |
| Citation 1, item 6 29 CFR 1910.217(c)(1)(i) · Mechanical power presses |
Serious | $1,000 | $655 | Jan 13, 2004 | Closed |
| Citation 1, item 7 29 CFR 1910.217(d)(9)(i) · Mechanical power presses |
Other-than-serious | $1,000 | $0 | Jan 13, 2004 | Closed |
| Citation 1, item 8 29 CFR 1910.217(e)(1)(i) · Mechanical power presses |
Serious | $1,000 | $655 | Jan 13, 2004 | Closed |
| Citation 1, item 9 29 CFR 1910.217(e)(1)(ii) · Mechanical power presses |
Other-than-serious | $1,000 | $0 | Jan 13, 2004 | Closed |
| Citation 1, item 10 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $1,250 | $435 | Jan 13, 2004 | Closed |
| Citation 1, item 11 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $1,000 | $350 | Jan 13, 2004 | Closed |
| Citation 2, item 1 29 CFR 1910.25(d)(2)(viii) · Portable wood ladders |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 2 29 CFR 1910.37(h)(1) · Exit routes |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 3 29 CFR 1910.106(d)(4)(iv) · Flammable liquids |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 4 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 5 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 6 29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 7 29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 8 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 9 29 CFR 1910.217(e)(3) · Mechanical power presses |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 10 29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 11 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 12 29 CFR 1910.303(e) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 13 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 14 29 CFR 1910.305(a)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 15 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 13, 2004 | Closed |
| Citation 2, item 16 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $0 | $100 | Jan 13, 2004 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2017, the Fort Wayne site logged 0 recordable injuries or illnesses among about 50 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Wayne Combustion Systems Fort Wayne · 2017 | 50 | 0 | 0 | 0.0 | 2.4 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.