OSHA SearchOSHA records by employer

Weatherford Artificial Lift Systems, LLC: OSHA inspections and violations

Longview, Texas · Oil and Gas Field Machinery and Equipment Manufacturing · NAICS 333132

7inspections
48citation items
$247,094current penalties
May 15, 2026last inspection

Since 2004, OSHA inspectors have visited Weatherford Artificial Lift Systems, LLC in Texas 7 times.

The most recent inspection opened on May 15, 2026 on a referral, in Odessa.

In all, OSHA issued 48 citation items: 47 serious and 1 other-than-serious.

The proposed penalties came to $298,323; today they stand at $247,094, 17% less.

The rule cited most here is 1910.1026 (hexavalent chromium), 15 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Weatherford Artificial Lift Systems, LLC averages $7,094 across 1 cited inspection.

Weatherford Artificial Lift Systems, LLC: OSHA citation items per year, 2004 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Weatherford Artificial Lift Systems, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348940792 OPENED MAY 15, 2026Closed

Referral · Partial · Safety · 125 employees at the site · Closed Aug 13, 2026

8866 N Loop, Odessa, TX 79760 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.39(a)(1) · Reporting deaths and severe injuries
Other-than-serious$11,823$7,094Jun 18, 2026Final

Inspection 336466180 OPENED SEP 19, 2012Closed

Referral · Partial · Safety · 300 employees at the site · Closed Feb 27, 2014

6501 Lee Street, Greenville, TX 75401 · All Other Miscellaneous Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$7,000$3,500Mar 12, 2013Final
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$7,000$5,500Mar 12, 2013Final
Citation 1, item 5
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$5,500$3,500Mar 12, 2013Final

Inspection 316094663 OPENED MAR 8, 2012Closed

Follow-up · Partial · Safety · 70 employees at the site · Closed Apr 4, 2012

2143 F.m. Road 2751, Longview, TX 75605 · Oil and Gas Field Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316094689 OPENED MAR 8, 2012Closed

Follow-up · Partial · Health · 101 employees at the site · Closed Oct 26, 2012

2143 F.m. Road 2751, Longview, TX 75605 · Oil and Gas Field Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1026(i)(4)(i) · Hexavalent chromium
Serious$5,500$2,500Sep 4, 2012Closed

Inspection 314176660 OPENED JUN 9, 2010Closed

Referral · Complete · Safety · 50 employees at the site · Closed Dec 21, 2010

2143 F.m. Road 2751, Longview, TX 75605 · Oil and Gas Field Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(2) · General requirements
Serious$3,500$3,500Nov 23, 2010Closed
Citation 1, item 2
29 CFR 1910.22(b)(2) · General requirements
Serious$2,500$2,500Nov 23, 2010Closed
Citation 1, item 3
29 CFR 1910.37(a)(3) · Exit routes
Serious$2,500$2,500Nov 23, 2010Closed
Citation 1, item 4
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 5
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 6
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 7
29 CFR 1910.111(b)(10)(ii) · Storage and handling of anhydrous ammonia
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 8a
29 CFR 1910.111(b)(10)(iii) · Storage and handling of anhydrous ammonia
Serious$2,500$2,500Nov 23, 2010Closed
Citation 1, item 8b
29 CFR 1910.124(g)(2) · General requirements for dipping and coating operations
Serious$0$0Nov 23, 2010Closed
Citation 1, item 10a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 10b
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Serious$0$0Nov 23, 2010Closed
Citation 1, item 11
29 CFR 1910.179(l)(3)(iiid) · Overhead and gantry cranes
Serious$2,500$2,500Nov 23, 2010Closed
Citation 1, item 12a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,000$2,000Nov 23, 2010Closed
Citation 1, item 12b
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 23, 2010Closed
Citation 1, item 13
29 CFR 1910.212(b) · Machine guarding
Serious$1,500$1,500Nov 23, 2010Closed
Citation 1, item 14a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$2,500$2,500Nov 23, 2010Closed
Citation 1, item 14b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Nov 23, 2010Closed
Citation 1, item 15
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 16a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 16b
29 CFR 1910.305(a)(2)(vc) · Electrical wiring methods
Serious$0$0Nov 23, 2010Closed
Citation 1, item 17
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 18
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 19
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 20
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 21
29 CFR 1910.212(a)(1) · Machine guarding
Serious$10,000$7,000Nov 23, 2010Closed
Citation 1, item 22
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$12,500$7,000Nov 23, 2010Closed
Citation 1, item 23
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$7,000Nov 23, 2010Closed

Inspection 314176439 OPENED MAY 24, 2010Closed

Complaint · Partial · Health · 50 employees at the site · Closed Dec 21, 2010

2143 F.m. Road 2751, Longview, TX 75605 · Oil and Gas Field Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(5) · Respiratory protection
Serious$2,500$2,500Nov 23, 2010Closed
Citation 1, item 2
29 CFR 1910.1026(d)(2)(i) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 3
29 CFR 1910.1026(d)(4)(i) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 4
29 CFR 1910.1026(f)(1)(i) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 5
29 CFR 1910.1026(g)(2) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 6
29 CFR 1910.134(d)(3)(ib)(1) · Respiratory protection
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 7
29 CFR 1910.1026(h)(1) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 8
29 CFR 1910.1026(i)(3)(ii) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 9
29 CFR 1910.1026(i)(4)(i) · Hexavalent chromium
Serious$0$7,000Nov 23, 2010Closed
Citation 1, item 10
29 CFR 1910.1026(i)(5) · Hexavalent chromium
Serious$0$7,000Nov 23, 2010Closed
Citation 1, item 11
29 CFR 1910.1026(j)(1)(i) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 12
29 CFR 1910.1026(j)(1)(ii) · Hexavalent chromium
Serious$0$7,000Nov 23, 2010Closed
Citation 1, item 13
29 CFR 1910.1026(l)(1) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 14
29 CFR 1910.1026(l)(2)(ia) · Hexavalent chromium
Serious$7,000$7,000Nov 23, 2010Closed
Citation 1, item 15
29 CFR 1910.1026(l)(2)(ib) · Hexavalent chromium
Serious$0$7,000Nov 23, 2010Closed
Citation 1, item 16
29 CFR 1910.1026(c) · Hexavalent chromium
Serious$70,000$7,000Nov 23, 2010Closed

Inspection 307005058 OPENED JUN 28, 2004Closed

Programmed other · Partial · Health · 67 employees at the site · Closed Jul 2, 2004

905 S. Grandview Ave., Odessa, TX 79761 · Pump and Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(1)

(a) Basic requirement. (1) Within eight (8) hours after the death of any employee as a result of a work-related incident, you must report the fatality to the Occupational Safety and Health Administration (OSHA), U.S. Department of Labor.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (5 µgm/m 3), calculated as an 8-hour time-weighted average (TWA).

29 CFR 1910.1026(d)(2)(i)

(2) Scheduled monitoring option. (i) The employer shall perform initial monitoring to determine the 8-hour TWA exposure for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area. Where an employer does representative sampling instead of sampling all employees in order to meet this requirement, the employer shall sample the employee(s) expected to have the highest chromium (VI) exposures.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.111 · Storage and handling of anhydrous ammonia

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.124 · General requirements for dipping and coating operations

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other oil and gas field machinery and equipment manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.