2inspections
22citation items
$17,688current penalties
Jul 16, 2015last inspection

OSHA has inspected Wise Recycling East I, LLC 2 times in North Carolina since 2014.

The latest one began on Jul 16, 2015 to follow up on an earlier case, in Charlotte.

Those inspections ended with 22 citation items: 6 serious, 1 repeat and 15 other-than-serious.

Penalties were first proposed at $21,950 and now stand at $17,688, 19% lower after settlements or reviews.

Forklifts and other powered industrial trucks comes up most often in these citations: 4 items under 1910.178.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,424, and Wise Recycling East I, LLC averages $6,008 (1 cited inspection).

Wise Recycling East I, LLC: OSHA citation items per year, 2014 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Wise Recycling East I, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 318000437 OPENED JUL 16, 2015Closed

Follow-up · Complete · Health · 6 employees at the site · Closed Sep 21, 2015

600 East Sugar Creek Road, Charlotte, NC 28213 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Repeat$0$128Aug 20, 2015Closed
Citation 2, item 1
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$1,050$840Aug 20, 2015Closed
Citation 2, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$2,100$1,680Aug 20, 2015Closed
Citation 3, item 1
29 CFR 1910.36(d)(1) · Exit route design
Other-than-serious$1,050$840Aug 20, 2015Closed
Citation 3, item 2
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$1,050$840Aug 20, 2015Closed
Citation 3, item 3
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$1,050$840Aug 20, 2015Closed
Citation 3, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 20, 2015Closed
Citation 3, item 5
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$1,050$840Aug 20, 2015Closed
Citation 3, item 6
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Aug 20, 2015Closed

Inspection 317841922 OPENED SEP 30, 2014Closed

Accident · Complete · Health · 9 employees at the site · Closed Jun 10, 2015

600 East Sugar Creek Road, Charlotte, NC 28213 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$4,900$3,920Mar 24, 2015Closed
Citation 1, item 1b
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$0$0Mar 24, 2015Closed
Citation 1, item 2
29 CFR 1910.178(m)(7) · Forklifts and other powered industrial trucks
Serious$4,900$3,920Mar 24, 2015Closed
Citation 1, item 3
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$3,000$2,400Mar 24, 2015Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 3 Other-than-serious$900$720Mar 24, 2015Closed
Citation 2, item 4
29 CFR 1910.106(g)(9) · Flammable liquids
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 5
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 6
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 7
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 8
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 24, 2015Closed
Citation 2, item 9
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$900$720Mar 24, 2015Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other recyclable material merchant wholesalers employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.