OSHA SearchOSHA records by employer

Woodco Prefinishing Inc: OSHA inspections and violations

Brooklyn Center, Minnesota · Other Millwork (including Flooring) · NAICS 321918

8inspections
37citation items
$9,164current penalties
Nov 7, 2024last inspection

Woodco Prefinishing Inc has 8 OSHA inspections on record in Minnesota, the first in 1992.

OSHA's last visit started on Nov 7, 2024 as a planned inspection, in Minneapolis.

Across those inspections OSHA issued 37 citation items: 25 serious and 12 other-than-serious.

OSHA proposed $10,965 in penalties. After settlements and reviews the total is $9,164, down 16%.

Most often, OSHA cited 1910.106, flammable liquids (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Woodco Prefinishing Inc averages $1,455 over 2 cited inspections in that time.

Woodco Prefinishing Inc also files yearly injury logs with OSHA, summarized below.

Woodco Prefinishing Inc: OSHA citation items per year, 1992 to 2024
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

370employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Woodco Prefinishing Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347867632 OPENED NOV 7, 2024Closed

Planned · Complete · Safety · 18 employees at the site · Closed Jan 22, 2025

3140 103rd Lane Ne, Minneapolis, MN 55449 · Wood Preservation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.676
Serious$250$250Dec 31, 2024Final

Inspection 343708442 OPENED JAN 10, 2019Closed

Planned · Complete · Safety · 30 employees at the site · Closed Feb 22, 2019

3140 103rd Lane Ne, Minneapolis, MN 55449 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$400$280Jan 24, 2019Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$300$210Jan 24, 2019Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$500$350Jan 24, 2019Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,100$770Jan 24, 2019Final
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$300$210Jan 24, 2019Final
Citation 1, item 6
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$400$280Jan 24, 2019Final
Citation 1, item 7 Serious$400$280Jan 24, 2019Final
Citation 2, item 1
29 CFR 1910.36(d)(1) · Exit route design
Other-than-serious$100$70Jan 24, 2019Final
Citation 2, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$100$70Jan 24, 2019Final
Citation 2, item 3 Other-than-serious$200$140Jan 24, 2019Final

Inspection 316870658 OPENED DEC 5, 2012Closed

Planned · Complete · Health · 17 employees at the site · Closed Jan 17, 2013

3140 103rd Lane Ne, Blaine, MN 55449 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$225$158Dec 27, 2012Closed

Inspection 312534340 OPENED SEP 10, 2008Closed

Planned · Complete · Health · 12 employees at the site · Closed Sep 19, 2008

3140 103rd Lane Ne, Blaine, MN 55449 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310886726 OPENED JAN 31, 2007Closed

Planned · Complete · Safety · 12 employees at the site · Closed Mar 9, 2007

3140 103rd Lane Ne, Blaine, MN 55449 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$100$70Feb 20, 2007Closed

Inspection 308720408 OPENED FEB 28, 2005Closed

Planned · No inspection · Health · Closed Feb 28, 2005

6800 Shingle Creek Parkway, Suite 370, Brooklyn Center, MN 55430 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304804487 OPENED JAN 9, 2002Closed

Planned · Complete · Safety · 8 employees at the site · Closed May 6, 2002

6800 Shingle Creek Parkway, Suite 370, Brooklyn Center, MN 55430 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Jan 24, 2002Closed
Citation 1, item 2
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$500$500Jan 24, 2002Closed
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$375$375Jan 24, 2002Closed
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$375$375Jan 24, 2002Closed
Citation 1, item 5 Serious$500$500Jan 24, 2002Closed
Citation 1, item 6 Serious$500$500Jan 24, 2002Closed

Inspection 120439476 OPENED OCT 15, 1992Closed

Referral · Partial · Health · 9 employees at the site · Closed Apr 3, 1995

6800 Shingle Creek Parkway, Suite 370, Brooklyn Center, MN 55430 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$420$225Nov 23, 1992Final
Citation 1, item 2a
29 CFR 1910.106(d)(7)(ia) · Flammable liquids
Serious$420$339Nov 23, 1992Final
Citation 1, item 2b
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Serious$0$0Nov 23, 1992Closed
Citation 1, item 3
29 CFR 1910.106(e)(2)(iib)(2) · Flammable liquids
Serious$532$532Nov 23, 1992Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$420$339Nov 23, 1992Final
Citation 1, item 5a
29 CFR 1910.1000(d)(2)(i) · Air contaminants
Serious$840$840Nov 23, 1992Closed
Citation 1, item 5b
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Nov 23, 1992Closed
Citation 1, item 5c
29 CFR 1910.1000(f)(2)(i) · Air contaminants
Serious$0$0Nov 23, 1992Closed
Citation 1, item 6 Serious$308$308Nov 23, 1992Closed
Citation 2, item 1
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Other-than-serious$0$0Nov 23, 1992Closed
Citation 2, item 2
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$168$168Nov 23, 1992Closed
Citation 2, item 3
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$210$210Nov 23, 1992Closed
Citation 2, item 4
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$140$0Nov 23, 1992Final
Citation 2, item 5
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$252$252Nov 23, 1992Closed
Citation 2, item 6
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$210$143Nov 23, 1992Final
Citation 2, item 7
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$168$168Nov 23, 1992Closed
Citation 2, item 8 Other-than-serious$252$252Nov 23, 1992Closed
Citation 2, item 9 Other-than-serious$0$0Nov 23, 1992Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Minneapolis site logged 0 recordable injuries or illnesses among about 23 workers: 0.0 per 100 full-time workers, against a median of 4.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Woodco Prefinishing LLC
Minneapolis · 2025
23 000.04.6
Woodco Prefinishing Inc
Blaine · 2024
21 000.04.6

Included with any plan: 4 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(d)(2)(i)

(2)(i) In case of a mixture of air contaminants an employer shall compute the equivalent exposure as follows:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

29 CFR 1910.36 · Exit route design

29 CFR 5205.116

29 CFR 5206.1000

29 CFR 5206.700

Other other millwork (including flooring) employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.