OSHA SearchOSHA records by employer

X-L Plastics Inc: OSHA inspections and violations

Clifton, New Jersey · Plastics Bag and Pouch Manufacturing · NAICS 326111

27inspections
161citation items
$55,855current penalties
Feb 15, 2023last inspection

Since 1977, OSHA inspectors have visited X-L Plastics Inc in New Jersey 27 times.

The most recent inspection opened on Feb 15, 2023 on a referral, in Clifton.

In all, OSHA issued 161 citation items: 106 serious, 3 repeat and 52 other-than-serious.

The proposed penalties came to $149,001; today they stand at $55,855, 63% less.

The rule cited most here is 1910.219 (belts, pulleys and power-transmission parts), 14 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. X-L Plastics Inc averages $18,430 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

X-L Plastics Inc also files yearly injury logs with OSHA, summarized below.

X-L Plastics Inc: OSHA citation items per year, 1977 to 2023
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

272employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch X-L Plastics Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346506991 OPENED FEB 15, 2023Closed

Referral · Partial · Safety · 200 employees at the site · Closed May 11, 2023

220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346187883 OPENED AUG 25, 2022Closed

Referral · Partial · Safety · 120 employees at the site · Closed Jan 8, 2025

220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(c)(1) · Exit route design
Other-than-serious$6,153$4,600Dec 21, 2022Final
Citation 1, item 2
29 CFR 1910.37(b)(4) · Exit routes
Other-than-serious$6,153$4,600Dec 21, 2022Final
Citation 1, item 4a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$12,307$9,230Dec 21, 2022Final
Citation 2, item 1b Repeat$28,714$0Dec 21, 2022Final
Citation 2, item 2c
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Repeat$28,714$0Dec 21, 2022Final

Inspection 312866122 OPENED JUN 23, 2010Closed

Monitoring · Partial · Safety · 140 employees at the site · Closed Jun 23, 2010

220 Clifton Boulevard, Clifton, NJ 07015 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312861040 OPENED SEP 3, 2009Closed

Complaint · Partial · Safety · 140 employees at the site · Closed Jan 21, 2011

220 Clifton Boulevard, Clifton, NJ 07015 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(g)(2) · Exit route design
Serious$1,400$1,032Jan 22, 2010Closed
Citation 1, item 4
29 CFR 1910.141(d)(1) · Sanitation
Serious$1,400$1,032Jan 22, 2010Closed
Citation 1, item 5
29 CFR 1910.176(c) · Material storage and aisles
Other-than-serious$1,400$700Jan 22, 2010Closed
Citation 1, item 6c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jan 22, 2010Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 22, 2010Closed
Citation 2, item 2
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Jan 22, 2010Closed
Citation 2, item 3a
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$700$560Jan 22, 2010Closed
Citation 2, item 3b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jan 22, 2010Closed
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jan 22, 2010Closed
Citation 2, item 5
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 22, 2010Closed

Inspection 308615004 OPENED MAR 31, 2005Closed

Referral · Complete · Health · 140 employees at the site · Closed Jul 26, 2006

220 Clifton Boulevard, Clifton, NJ 07015 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,100$800Jul 28, 2005Final
Citation 1, item 2
29 CFR 1910.253(b)(5)(iiq) · Gas welding and cutting
Serious$1,375$900Jul 28, 2005Final

Inspection 308615012 OPENED MAR 31, 2005Closed

Unprogrammed related · Partial · Safety · 140 employees at the site · Closed Mar 13, 2007

220 Clifton Boulevard, Clifton, NJ 07015 · Paper Bag and Coated and Treated Paper Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$1,125$650Aug 10, 2005Final
Citation 1, item 3a
29 CFR 1910.178(m)(5)(iii) · Forklifts and other powered industrial trucks
Serious$900$700Aug 10, 2005Final
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,125$850Aug 10, 2005Final
Citation 1, item 5
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$675$400Aug 10, 2005Final
Citation 1, item 6
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$675$0Aug 10, 2005Final
Citation 2, item 1
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Aug 10, 2005Final

Inspection 306556507 OPENED DEC 4, 2003Closed

Other · Records only · Safety · 100 employees at the site · Closed Aug 30, 2006

220 Clifton Boulevard, Clifton, NJ 07015 · Paper Bag and Coated and Treated Paper Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.41(b)(2) · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA
Repeat$4,200$4,200Jan 9, 2004Closed

Inspection 305066516 OPENED JAN 10, 2002Closed

Other · Records only · Safety · 100 employees at the site · Closed Feb 22, 2002

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$600$600Feb 6, 2002Closed
19 older inspections

Inspection 301954830 OPENED JAN 25, 1999Closed

Follow-up · Partial · Safety · 110 employees at the site · Closed Jan 25, 1999

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301953733 OPENED NOV 19, 1998Closed

Referral · Partial · Safety · 110 employees at the site · Closed Jan 25, 1999

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(2) · General requirements
Serious$1,400$1,000Dec 9, 1998Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,750$1,000Dec 9, 1998Closed
Citation 1, item 3
29 CFR 1910.176(b) · Material storage and aisles
Serious$1,400$1,000Dec 9, 1998Closed
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,750$1,000Dec 9, 1998Closed
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,750$1,000Dec 9, 1998Closed

Inspection 301953808 OPENED NOV 19, 1998Closed

Referral · Partial · Health · 110 employees at the site · Closed Jan 25, 1999

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,400$1,000Dec 9, 1998Closed
Citation 1, item 1b Serious$0$0Dec 9, 1998Closed
Citation 1, item 2a
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,050$1,000Dec 9, 1998Closed
Citation 1, item 2b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Dec 9, 1998Closed
Citation 2, item 1b Other-than-serious$0$0Dec 9, 1998Closed

Inspection 101480861 OPENED JAN 14, 1992Closed

Follow-up · Partial · Safety · 100 employees at the site · Closed Jan 21, 1993

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,500$560Mar 26, 1992Final
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,500$560Mar 26, 1992Final
Citation 1, item 3
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$1,200$460Mar 26, 1992Final
Citation 1, item 4
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$1,200$460Mar 26, 1992Final
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,200$460Mar 26, 1992Final
Citation 2, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Mar 26, 1992Final
Citation 2, item 2
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Mar 26, 1992Final

Inspection 109867069 OPENED JAN 14, 1992Closed

Follow-up · Partial · Health · 100 employees at the site · Closed Apr 13, 1994

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a) · Exit routes
Serious$900$500Jun 23, 1992Final
Citation 1, item 2
29 CFR 1910.37(q)(2) · Exit routes
Serious$900$500Jun 23, 1992Final
Citation 1, item 3 Serious$1,125$700Jun 23, 1992Final
Citation 1, item 4
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Serious$900$500Jun 23, 1992Final
Citation 1, item 5
29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response
Serious$900$500Jun 23, 1992Final
Citation 1, item 6
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$900$500Jun 23, 1992Final
Citation 1, item 7
29 CFR 1910.253(a)(3) · Gas welding and cutting
Serious$900$500Jun 23, 1992Final
Citation 1, item 8a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$900$500Jun 23, 1992Final
Citation 1, item 8b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$0$0Jun 23, 1992Final
Citation 1, item 8c
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Jun 23, 1992Closed
Citation 1, item 8d
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Jun 23, 1992Closed
Citation 1, item 8e
29 CFR 1910.1200(f)(8) · Hazard communication
Serious$0$0Jun 23, 1992Closed
Citation 1, item 8f
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jun 23, 1992Closed

Inspection 109869644 OPENED JAN 15, 1991Closed

Referral · Complete · Health · 90 employees at the site · Closed Apr 13, 1994

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$810$325May 22, 1991Final
Citation 1, item 2
29 CFR 1910.106(d)(2)(iii) · Flammable liquids
Serious$630$250May 22, 1991Final
Citation 1, item 3a
29 CFR 1910.106(e)(2)(iii) · Flammable liquids
Serious$630$250May 22, 1991Final
Citation 1, item 3b
29 CFR 1910.106(e)(2)(ivb) · Flammable liquids
Serious$0$0May 22, 1991Final
Citation 1, item 3c
29 CFR 1910.106(e)(9)(i) · Flammable liquids
Serious$0$0May 22, 1991Final
Citation 1, item 4
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Serious$630$250May 21, 1991Final
Citation 1, item 5
29 CFR 1910.106(e)(2)(ivc) · Flammable liquids
Serious$630$250May 22, 1991Final
Citation 1, item 6
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$630$250May 22, 1991Final
Citation 1, item 7
29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response
Serious$720$280May 22, 1991Final
Citation 1, item 8
29 CFR 1910.151(c) · First aid and eyewash
Serious$630$250May 22, 1991Final
Citation 1, item 9a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$720$280May 22, 1991Final
Citation 1, item 9b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$0$0May 22, 1991Final
Citation 1, item 9c
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0May 22, 1991Final
Citation 1, item 10
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$720$280May 22, 1991Final
Citation 1, item 11a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$720$280May 22, 1991Final
Citation 1, item 11b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$0$0May 22, 1991Final
Citation 1, item 12a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$720$280May 22, 1991Final
Citation 1, item 12b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0May 22, 1991Final
Citation 1, item 13
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$630$250May 22, 1991Final
Citation 1, item 14
29 CFR 1910.1200(h) · Hazard communication
Serious$720$280May 22, 1991Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0May 22, 1991Final
Citation 2, item 2
29 CFR 1910.106(e)(7)(i) · Flammable liquids
Other-than-serious$0$0May 22, 1991Final
Citation 2, item 3 Other-than-serious$0$0May 22, 1991Final
Citation 2, item 4 Other-than-serious$0$0May 22, 1991Final
Citation 2, item 5 Other-than-serious$0$0May 22, 1991Final

Inspection 109869818 OPENED JAN 15, 1991Closed

Referral · Complete · Safety · 90 employees at the site · Closed Jul 10, 1992

220 Clifton Boulevard, Clifton, NJ 07015 · OSHA's record · Phone and website on Google Maps

Incident on Jan 20, 1991 (fatal): Employee dies from head injury after fall from platform

Employee #1, a machine operator, was standing on an elevated work platform feedi ng recycled plastic rolls into a Herbold heavy duty grinder. The platform, which measured 5 ft wide by 11 1/2 in. long, and was located 50 in. above floor level , was not properly guarded with standard railings. Employee #1 was required to m ove around the platform as he picked up the plastic rolls loaded on the platform floor. As he worked, he lost his balance and fell through one of the unguarded sides to the concrete floor. He suffered severe head injuries and was taken to t he hospital unconscious. He was diagnosed as brain dead on arrival and died at t he hospital a week later.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$810$325Mar 12, 1991Final
Citation 1, item 2
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Serious$450$180Mar 12, 1991Final
Citation 1, item 3
29 CFR 1910.24(b) · Fixed industrial stairs
Serious$810$325Mar 12, 1991Final
Citation 1, item 4
29 CFR 1910.37(q)(5) · Exit routes
Serious$450$180Mar 12, 1991Final
Citation 1, item 5
29 CFR 1910.106(e)(2)(iib) · Flammable liquids
Serious$450$180Mar 12, 1991Final
Citation 1, item 6
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$540$215Mar 12, 1991Final
Citation 1, item 7
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$450$180Mar 12, 1991Final
Citation 1, item 8
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$450$180Mar 12, 1991Final
Citation 1, item 9
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Serious$450$180Mar 12, 1991Final
Citation 1, item 10
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$540$225Mar 12, 1991Final
Citation 1, item 11
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$540$225Mar 12, 1991Final
Citation 1, item 12
29 CFR 1910.212(a)(1) · Machine guarding
Serious$900$360Mar 12, 1991Final
Citation 1, item 13
29 CFR 1910.212(a)(2) · Machine guarding
Serious$540$225Mar 12, 1991Final
Citation 1, item 14
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$630$250Mar 12, 1991Final
Citation 1, item 15
29 CFR 1910.212(b) · Machine guarding
Serious$450$180Mar 12, 1991Final
Citation 1, item 16
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$450$180Mar 12, 1991Final
Citation 1, item 17
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$360$150Mar 12, 1991Final
Citation 1, item 18a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$450$180Mar 12, 1991Final
Citation 1, item 18b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 12, 1991Final
Citation 1, item 18c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 12, 1991Final
Citation 1, item 19
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$630$250Mar 12, 1991Final
Citation 1, item 20
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$630$250Mar 12, 1991Final
Citation 1, item 21
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Serious$540$215Mar 12, 1991Final
Citation 1, item 22
29 CFR 1910.253(b)(4)(ii) · Gas welding and cutting
Serious$360$150Mar 12, 1991Final
Citation 1, item 23
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$540$215Mar 12, 1991Final
Citation 1, item 24
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$540$215Mar 12, 1991Final
Citation 1, item 25
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$540$215Mar 12, 1991Final
Citation 1, item 26
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$540$215Mar 12, 1991Final
Citation 2, item 1
29 CFR 1904.6 · Determination of new cases
Other-than-serious$90$50Mar 12, 1991Final
Citation 2, item 2
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$0$0Mar 12, 1991Final
Citation 2, item 3
29 CFR 1910.22(b)(2) · General requirements
Other-than-serious$0$0Mar 12, 1991Final

Inspection 100683572 OPENED JUN 12, 1987Closed

Follow-up · Partial · Safety · 75 employees at the site · Closed Jun 15, 1987

220 Cliton Boulevard, Clifton, NJ 07011 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100685395 OPENED MAR 13, 1987Closed

Unprogrammed related · Partial · Health · 75 employees at the site · Closed Apr 7, 1987

220 Clifton Boulevard, Clifton, NJ 07011 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100204429 OPENED FEB 12, 1987Closed

Planned · Complete · Safety · 75 employees at the site · Closed Jun 15, 1987

220 Clifton Boulevard, Clifton, NJ 07011 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 27, 1987Closed
Citation 1, item 2
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Feb 27, 1987Closed
Citation 1, item 3
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Feb 27, 1987Closed
Citation 1, item 4
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 27, 1987Closed
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Feb 27, 1987Closed
Citation 1, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 27, 1987Closed
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 27, 1987Closed

Inspection 612564 OPENED FEB 28, 1986Closed

Referral · Partial · Health · 75 employees at the site · Closed Apr 1, 1986

220 Clifton Boulevard, Clifton, NJ 07011 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1721117 OPENED APR 25, 1984Closed

Planned · Complete · Safety · 60 employees at the site · Closed Jun 7, 1984

220 Clifton Blvd, Clifton, NJ 07011 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(b)(1)(i) · Guarding floor and wall openings and holes
Serious$80$40May 3, 1984Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$80$40May 3, 1984Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$80$40May 3, 1984Closed
Citation 1, item 3b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 3, 1984Closed
Citation 1, item 4
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$80$40May 3, 1984Closed
Citation 1, item 5
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$80$40May 3, 1984Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$80$40May 3, 1984Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 2
29 CFR 1910.36(d)(2) · Exit route design
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 3
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 4
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 5
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 6
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 7
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 8
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 9
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 10
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0May 3, 1984Closed
Citation 2, item 11
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0May 3, 1984Closed

Inspection 11422417 OPENED JUN 22, 1982Closed

Planned · Complete · Safety · 42 employees at the site · Closed Aug 3, 1982

234 Middlesex St, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$120$120Jun 29, 1982Closed
Citation 2, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 29, 1982Closed

Inspection 11185196 OPENED OCT 15, 1980Closed

Follow-up · Complete · Safety · 40 employees at the site · Closed Mar 10, 1984

234 Middlesex Street, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 11184983 OPENED SEP 4, 1980Closed

Planned · Complete · Safety · 40 employees at the site · Closed Oct 20, 1980

234 Middlesex Street, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$160$160Sep 10, 1980Closed
Citation 1, item 2a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$120$120Sep 10, 1980Closed
Citation 1, item 2b
29 CFR 1910.106(d)(6)(iv) · Flammable liquids
Serious$0$0Sep 10, 1980Closed
Citation 1, item 3
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$120$120Sep 10, 1980Closed
Citation 1, item 4 Serious$120$120Sep 10, 1980Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 10, 1980Closed
Citation 2, item 2
29 CFR 1910.27(f) · Fixed ladders
Other-than-serious$0$0Sep 10, 1980Closed
Citation 2, item 3
29 CFR 1910.37(k)(1) · Exit routes
Other-than-serious$0$0Sep 10, 1980Closed
Citation 2, item 4
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Other-than-serious$0$0Sep 10, 1980Closed
Citation 2, item 5 Other-than-serious$0$0Sep 10, 1980Closed
Citation 2, item 6 Other-than-serious$0$0Sep 10, 1980Closed
Citation 2, item 7 Other-than-serious$0$0Sep 10, 1980Closed

Inspection 11203080 OPENED MAR 27, 1979Closed

Follow-up · Complete · Safety · 33 employees at the site · Closed Mar 10, 1984

234 Middlesex Street, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 11203015 OPENED MAR 2, 1979Closed

Planned · Complete · Safety · 33 employees at the site · Closed Apr 17, 1979

234 Middlesex Street, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.24(f) · Fixed industrial stairs
Serious$200$200Mar 7, 1979Closed
Citation 1, item 1b
29 CFR 1910.24(h) · Fixed industrial stairs
Serious$0$0Mar 7, 1979Closed
Citation 1, item 2
29 CFR 1910.178(e)(1) · Forklifts and other powered industrial trucks
Serious$200$200Mar 7, 1979Closed

Inspection 11201266 OPENED JUL 22, 1977Closed

Follow-up · Complete · Safety · 22 employees at the site · Closed Mar 10, 1984

234-242 Middlesex Street, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 11201159 OPENED JUN 16, 1977Closed

Complaint · Complete · Safety · 22 employees at the site · Closed Aug 23, 1977

234-242 Middlesex Street, Harrison, NJ 07029 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$90$90Jul 8, 1977Closed
Citation 1, item 2
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$150$150Jul 8, 1977Closed
Citation 1, item 3
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$120$120Jul 8, 1977Closed
Citation 1, item 4 Serious$90$90Jul 8, 1977Closed
Citation 1, item 5 Serious$120$120Jul 8, 1977Closed
Citation 2, item 1
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Jul 8, 1977Closed
Citation 2, item 2 Other-than-serious$0$0Jul 8, 1977Closed
Citation 2, item 3
29 CFR 1910.157(a)(5) · Portable fire extinguishers
Other-than-serious$0$0Jul 8, 1977Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Clifton site logged 14 recordable injuries or illnesses among about 150 workers: 28.0 per 100 full-time workers, against a median of 1.1 for its industry. Those cases cost 328 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
7782_19064
Clifton · 2024
150 141428.01.1
X-L Plastics inc
Clifton · 2022
219 552.02.6

Included with any plan: 1 more yearly log from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.17

29 CFR 1904.41 · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA

29 CFR 1904.41(b)(2)

(2) Do part-time, seasonal, or temporary workers count as employees in the criteria for number of employees in paragraph (a) of this section? Yes, each individual employed in the establishment at any time during the calendar year counts as one employee, including full-time, part-time, seasonal, and temporary workers.

29 CFR 1904.6 · Determination of new cases

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(iii)

(iii) Size. Flammable liquid containers shall be in accordance with Table H-12, except that glass or plastic containers of no more than 1-gallon capacity may be used for a Category 1 or 2 flammable liquid if:

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.309

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other plastics bag and pouch manufacturing employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.