OSHA SearchOSHA records by employer

York Plant Holding, LLC: OSHA inspections and violations

York, Pennsylvania · Fossil Fuel Electric Power Generation · NAICS 221112

1inspections
10citation items
$7,000current penalties
Feb 1, 2016last inspection

OSHA inspectors have visited York Plant Holding, LLC in Pennsylvania one time.

It opened on Feb 1, 2016 after a complaint, in York.

In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

The proposed penalties came to $12,600; today they stand at $7,000, 44% less.

The rule cited most here is 1910.120 (hazardous waste operations and emergency response), 6 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. York Plant Holding, LLC averages $7,000 across 1 cited inspection.

York Plant Holding, LLC also files yearly injury logs with OSHA, summarized below.

York Plant Holding, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch York Plant Holding, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341218063 OPENED FEB 1, 2016Closed

Complaint · Partial · Safety · 63 employees at the site · Closed Apr 6, 2016

651 Memory Lane, York, PA 17402 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,100$1,000Feb 19, 2016Final
Citation 1, item 2a
29 CFR 1910.120(q)(2)(i) · Hazardous waste operations and emergency response
Serious$3,500$6,000Feb 19, 2016Final
Citation 1, item 2b
29 CFR 1910.120(q)(2)(iii) · Hazardous waste operations and emergency response
Serious$0$0Feb 19, 2016Final
Citation 1, item 2c
29 CFR 1910.120(q)(2)(vii) · Hazardous waste operations and emergency response
Serious$0$0Feb 19, 2016Final
Citation 1, item 2d
29 CFR 1910.120(q)(2)(xi) · Hazardous waste operations and emergency response
Serious$0$0Feb 19, 2016Final
Citation 1, item 2e
29 CFR 1910.120(q)(3)(iii) · Hazardous waste operations and emergency response
Serious$3,500$0Feb 19, 2016Final
Citation 1, item 2f
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$0$0Feb 19, 2016Final
Citation 1, item 2g
29 CFR 1910.120(q)(6) · Hazardous waste operations and emergency response
Serious$3,500$0Feb 19, 2016Final
Citation 2, item 1
29 CFR 1910.137(c)(2)(viii) · Electrical protective equipment
Other-than-serious$0$0Feb 19, 2016Final
Citation 2, item 2
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 19, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the York site logged 0 recordable injuries or illnesses among about 5 workers: 0.0 per 100 full-time workers, against a median of 1.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
York Plant Holding, LLC
York · 2019
5 000.01.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.120(q)(2)(i)

(i) Pre-emergency planning and coordination with outside parties.

29 CFR 1910.120(q)(2)(iii)

(iii) Emergency recognition and prevention.

29 CFR 1910.120(q)(2)(vii)

(vii) Decontamination.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.137 · Electrical protective equipment

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.23 · Guarding floor and wall openings and holes

Other fossil fuel electric power generation employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.