Inspection 347808917 OPENED OCT 10, 2024Closed
2220 Paradise Church Road, Mount Pleasant Mills, PA 17853 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Mount Pleasant Mills, Pennsylvania · Wood Container and Pallet Manufacturing · NAICS 321920
A & L Wood, Inc. has 6 OSHA inspections on record in Pennsylvania, the first in 1986.
OSHA's last visit started on Oct 10, 2024 as a planned inspection, in Mount Pleasant Mills.
Across those inspections OSHA issued 16 citation items: 16 serious.
OSHA proposed $16,635 in penalties. After settlements and reviews the total is $10,426, down 37%.
Most often, OSHA cited 1910.107, spray painting and finishing (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. A & L Wood, Inc. averages $3,163 over 2 cited inspections in that time.
Pennsylvania · latest 90 days of OSHA records
274employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch A & L Wood, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company2220 Paradise Church Road, Mount Pleasant Mills, PA 17853 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2220 Paradise Church Road, Mount Pleasant Mills, PA 17853 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $2,100 | $1,575 | Nov 10, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $1,575 | $1,181 | Nov 10, 2015 | Final |
2220 Paradise Church Road, Mount Pleasant Mills, PA 17853 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.95(g)(1) · Noise |
Serious | $2,380 | $1,785 | Sep 28, 2015 | Final |
| Citation 1, item 1b 29 CFR 1910.95(k)(1) · Noise |
Serious | $0 | $0 | Sep 28, 2015 | Final |
| Citation 1, item 2a 29 CFR 1910.107(b)(1) · Spray painting and finishing |
Serious | $2,380 | $1,785 | Sep 28, 2015 | Final |
| Citation 1, item 2b 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $0 | $0 | Sep 28, 2015 | Final |
| Citation 1, item 2c 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $0 | $0 | Sep 28, 2015 | Final |
3418 Red Bank Road, Mount Pleasant Mills, PA 17853 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2220 Paradise Church Road, Mount Pleasant Mills, PA 17853 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $2,500 | $1,250 | Nov 1, 2007 | Closed |
| Citation 1, item 2a 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Serious | $750 | $375 | Nov 1, 2007 | Closed |
| Citation 1, item 2b 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Nov 1, 2007 | Closed |
| Citation 1, item 2c 29 CFR 1910.24(f) · Fixed industrial stairs |
Serious | $0 | $0 | Nov 1, 2007 | Closed |
| Citation 1, item 3 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $875 | $437 | Nov 1, 2007 | Closed |
| Citation 1, item 4a 29 CFR 1910.147(d)(6) · Lockout/tagout |
Serious | $2,500 | $1,250 | Nov 1, 2007 | Closed |
| Citation 1, item 4b 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Nov 1, 2007 | Closed |
| Citation 1, item 5 29 CFR 1910.178(l)(3)(im) · Forklifts and other powered industrial trucks |
Serious | $875 | $438 | Nov 1, 2007 | Closed |
| Citation 1, item 6 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $700 | $350 | Nov 1, 2007 | Closed |
Off Rt. 104 South, Mount Pleasant Mills, PA 17853 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(1)
(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.
29 CFR 1910.107(c)(5)
(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.