American Axle & Manufacturing, Inc.: OSHA inspections and violations
Lancaster, Pennsylvania · Motor Vehicle Transmission and Power Train Parts Manufacturing · NAICS 336350
2inspections
5citation items
$10,400current penalties
Jan 31, 2020last inspection
American Axle & Manufacturing, Inc. has 2 OSHA inspections on record in Pennsylvania, the first in 2011.
OSHA's last visit started on Jan 31, 2020 as a planned inspection, in Saint Marys.
Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
OSHA proposed $10,603 in penalties. After settlements and reviews the total is $10,400, down 2%.
Most often, OSHA cited 1910.107, spray painting and finishing (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. American Axle & Manufacturing, Inc. averages $6,400 over 1 cited inspection in that time.
Citation items per year, by inspection date.
Pennsylvania · latest 90 days of OSHA records
274employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch American Axle & Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.
OSHA records show American Axle & Manufacturing, Inc. at 9 sites in 4 states. Together they've had 30 inspections and $96,210 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 9 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.