Astro Shapes, LLC.: OSHA inspections and violations
Struthers, Ohio · Alumina and Aluminum Production and Processing · NAICS 331316
11inspections
40citation items
$34,694current penalties
Mar 25, 2024last inspection
OSHA has inspected Astro Shapes, LLC. 11 times in Ohio since 1975.
The latest one began on Mar 25, 2024 on a referral, in Struthers.
Those inspections ended with 40 citation items: 14 serious and 26 other-than-serious.
Penalties were first proposed at $98,764 and now stand at $34,694, 65% lower after settlements or reviews.
Machine guarding comes up most often in these citations: 4 items under 1910.212.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Astro Shapes, LLC. averages $16,131 (1 cited inspection).
Astro Shapes, LLC. also files yearly injury logs with OSHA, summarized below.
It reported 5 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Ohio · latest 90 days of OSHA records
267employers cited
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
Incident on Feb 21, 2020: Employee amputates finger with dies
At 12:00 p.m. on February 21, 2020, an employee was using an overhead crane to place and remove dies into a press. The employee was using the overhead crane to place the die parts into the cradle so that they can go into the die. The process required an eye bolt in each part, and a chain connected to each part; then, movement with the overhead crane. The employee only hooked up one chain to one eye hook. When attempting to remove the die sets, they did not set properly and got off kilter. When the employee tried to lift the dies up via the crane, the dies moved and pinched the employee's finger. The employee suffered a partial amputation of the left middle finger and was treated without hospitalization.
No citations from this inspection.
Inspection 312673981 OPENED DEC 29, 2008Closed
Complaint · Partial · Safety · 300 employees at the site · Closed Feb 18, 2009
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Struthers site logged 26 recordable injuries or illnesses among about 518 workers: 5.0 per 100 full-time workers, against a median of 2.9 for its industry. Those cases cost 149 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Astro Shapes LLC
Struthers · 2025
518
26
8
5.0
2.9
Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 5 reports on file.
Mar 17, 2024, Struthers: Hospitalization · nonfatal 'crushing' injuries · ankle(s) and leg(s) n.e.c.
An employee was removing a die from a press. A powered industrial vehicle (PIV) was driving down the aisle and struck a buggy which struck the employee, wedging them against another buggy. The employee sustained a crush injury to their left ankle/calf that required surgery.
An employee was exiting a parked scissor lift. While descending the ladder, the employee fell to the ground and sustained a broken hip.
Feb 21, 2020, Struthers: Amputation · amputations · fingertip(s)
An employee was removing a die set when his left middle finger was caught between the cradle and the safety guard. The tip of the finger was amputated.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(a) Cylinders. Employers must ensure that the in-plant transfer, handling, storage, and use of acetylene in cylinders comply with the provisions of CGA Pamphlet G-1-2009 (“Acetylene”) (incorporated by reference, see § 1910.6).
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
29 CFR 1910.132 · Personal protective equipment, general requirements
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.