Inspection 348612367 OPENED NOV 25, 2025Closed
7060 Division Highway, Narvon, PA 17555 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Lancaster, Pennsylvania · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
OSHA has inspected B. J. Baldwin Electric Inc. 10 times in Pennsylvania since 1983.
The latest one began on Nov 25, 2025 on a referral, in Narvon.
Those inspections ended with 20 citation items: 12 serious and 8 other-than-serious.
Penalties were first proposed at $27,785 and now stand at $27,620, 1% lower after settlements or reviews.
Scope, application, and definitions applicable to this subpart comes up most often in these citations: 3 items under 1926.500.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and B. J. Baldwin Electric Inc. averages $25,350 (1 cited inspection).
1 inspection on this page followed a fatal incident.
B. J. Baldwin Electric Inc. also files yearly injury logs with OSHA, summarized below.
Pennsylvania · latest 90 days of OSHA records
285employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch B. J. Baldwin Electric Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company7060 Division Highway, Narvon, PA 17555 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
600 Old Hickory Road, Lancaster, PA 17601 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
102 Deka Road, Lyon Station, PA 19536 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Oct 19, 2016 (fatal): Employee contacts a live bus bar and was electrocuted.
At 11:00 a.m. on October 19, 2016, an employee was installing flex links when they contacted two 277 volt energized bus bars and they were killed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.333(b)(2)(iv)(b) · Working near live electrical parts |
Serious | $12,675 | $12,675 | Mar 9, 2017 | Final |
| Citation 1, item 3a 29 CFR 1926.416(a)(3) · Electrical safety in construction |
Serious | $12,675 | $12,675 | Mar 9, 2017 | Final |
| Citation 1, item 3b 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $0 | $0 | Mar 9, 2017 | Final |
P.o. Box 120 (bldg. 60), West Point, PA 19486 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1c 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $0 | $500 | Apr 20, 1994 | Closed |
600 E. Lincoln Highway, Exton, PA 19341 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.150(a)(1) · Fire protection |
Serious | $825 | $825 | Sep 4, 1991 | Closed |
| Citation 2, item 1 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Other-than-serious | $0 | $0 | Sep 4, 1991 | Closed |
216 Greenfield Road, Lancaster, PA 17522 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(a)(2)(iif) · Job-site wiring |
Other-than-serious | $0 | $0 | Aug 6, 1990 | Closed |
| Citation 1, item 2 29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Aug 6, 1990 | Closed |
| Citation 1, item 3 29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Aug 6, 1990 | Closed |
| Citation 1, item 4 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Aug 6, 1990 | Closed |
Along Ontelaunee Road, R.d. #1, Leesport, PA 19533 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $420 | $350 | Mar 8, 1990 | Closed |
Heather Wood Us Rt 322, Honey Brook, PA 19344 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.400(a)(11017) · Introduction |
Serious | $350 | $175 | Jan 14, 1985 | Closed |
| Citation 1, item 2a 29 CFR 1926.400(h)(2) · Introduction |
Serious | $420 | $210 | Jan 14, 1985 | Closed |
| Citation 1, item 2b 29 CFR 1926.401(a)(1) · [Reserved] |
Serious | $0 | $0 | Jan 14, 1985 | Closed |
| Citation 1, item 2c 29 CFR 1926.401(c) · [Reserved] |
Serious | $0 | $0 | Jan 14, 1985 | Closed |
| Citation 1, item 3 29 CFR 1926.500(e)(1)(iii) · Scope, application, and definitions applicable to this subpart |
Serious | $210 | $105 | Jan 14, 1985 | Closed |
| Citation 1, item 4 29 CFR 1926.500(e)(1)(iv) · Scope, application, and definitions applicable to this subpart |
Serious | $210 | $105 | Jan 14, 1985 | Closed |
| Citation 2, item 1 29 CFR 1926.24 · Fire protection and prevention |
Other-than-serious | $0 | $0 | Jan 14, 1985 | Closed |
| Citation 2, item 2 29 CFR 1926.100(a) · Hard hats in construction |
Other-than-serious | $0 | $0 | Jan 14, 1985 | Closed |
Willow Valley Manor, Willow Street, PA 17584 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.151(c)(6) · Fire prevention |
Other-than-serious | $0 | $0 | Dec 5, 1983 | Closed |
216 Greenfield Rd, Manheim, PA 17601 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Narvon site logged 3 recordable injuries or illnesses among about 279 workers: 1.2 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 30 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| B.J. Baldwin Electric Inc. Narvon · 2025 | 279 | 3 | 1 | 1.2 | 1.8 |
| Lancaster Electric Inc Lancaster · 2017 | 77 | 1 | 0 | 1.4 | 1.8 |
Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.333(b)(2)(iv)(b)
(B) A qualified person shall use test equipment to test the circuit elements and electrical parts of equipment to which employees will be exposed and shall verify that the circuit elements and equipment parts are deenergized. The test shall also determine if any energized condition exists as a result of inadvertently induced voltage or unrelated voltage backfeed even though specific parts of the circuit have been deenergized and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be checked for proper operation immediately before and immediately after this test.
29 CFR 1926.100(a)
(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.
29 CFR 1926.150(a)(1)
(a) General requirements. (1) The employer shall be responsible for the development of a fire protection program to be followed throughout all phases of the construction and demolition work, and he shall provide for the firefighting equipment as specified in this subpart. As fire hazards occur, there shall be no delay in providing the necessary equipment.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.