OSHA SearchOSHA records by employer

Bergari Solutions LLC: OSHA inspections and violations

Rosemount, Minnesota · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · NAICS 333412

5inspections
19citation items
$7,738current penalties
Aug 13, 2025last inspection

OSHA has inspected Bergari Solutions LLC 5 times in Minnesota since 2014.

The latest one began on Aug 13, 2025 as a planned inspection, in Rosemount.

Those inspections ended with 19 citation items: 12 serious and 7 other-than-serious.

Penalties were first proposed at $9,225 and now stand at $7,738, 16% lower after settlements or reviews.

Overhead and gantry cranes comes up most often in these citations: 4 items under 1910.179.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Bergari Solutions LLC averages $2,276 (3 cited inspections).

Bergari Solutions LLC: OSHA citation items per year, 2014 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

379employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Bergari Solutions LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348439357 OPENED AUG 13, 2025Closed

Planned · Complete · Health · 47 employees at the site · Closed Oct 7, 2025

2605 160th St W, Suite 109, Rosemount, MN 55068 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$600$360Sep 12, 2025Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,000$600Sep 12, 2025Final
Citation 1, item 3 Serious$800$480Sep 12, 2025Final
Citation 2, item 1 Other-than-serious$100$60Sep 12, 2025Final

Inspection 343942959 OPENED APR 18, 2019Closed

Planned · Complete · Safety · 20 employees at the site · Closed May 21, 2019

2605 160th St W, Suite 109, Rosemount, MN 55068 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$225$158Apr 23, 2019Final
Citation 2, item 1 Other-than-serious$100$70Apr 23, 2019Final

Inspection 343050837 OPENED MAR 27, 2018Closed

Complaint · Partial · Health · 12 employees at the site · Closed Jul 24, 2018

2605 160th St W, Suite 109, Rosemount, MN 55068 · Motor Vehicle Gasoline Engine and Engine Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$450$450Jun 22, 2018Final
Citation 1, item 2
29 CFR 1910.135(a)(1) · Head protection
Serious$825$825Jun 22, 2018Final
Citation 1, item 3
29 CFR 1910.179(b)(6)(i) · Overhead and gantry cranes
Serious$450$450Jun 22, 2018Final
Citation 1, item 4
29 CFR 1910.179(n)(2)(ii) · Overhead and gantry cranes
Serious$450$450Jun 22, 2018Final
Citation 1, item 5
29 CFR 1910.179(n)(3)(vi) · Overhead and gantry cranes
Serious$1,050$1,050Jun 22, 2018Final
Citation 1, item 6
29 CFR 1910.179(n)(3)(x) · Overhead and gantry cranes
Serious$1,050$1,050Jun 22, 2018Final
Citation 1, item 7 Serious$825$825Jun 22, 2018Final

Inspection 317911691 OPENED NOV 18, 2014Closed

Referral · Partial · Health · 14 employees at the site · Closed Jan 30, 2015

2605 160th St W, Suite 109, Rosemount, MN 55068 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$300$210Jan 8, 2015Closed

Inspection 317908176 OPENED NOV 6, 2014Closed

Planned · Complete · Safety · 14 employees at the site · Closed Mar 12, 2015

2605 160th St W, Suite 109, Rosemount, MN 55068 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$375$200Nov 19, 2014Final
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$125$125Nov 19, 2014Closed
Citation 2, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$250$150Nov 19, 2014Final
Citation 2, item 3
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$125$125Nov 19, 2014Closed
Citation 2, item 4 Other-than-serious$125$100Nov 19, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.135 · Head protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 5205.110

29 CFR 5205.116

29 CFR 5205.1200

29 CFR 5205.670

29 CFR 5205.675

Other ventilation, heating, air-conditioning, and commercial refrigeration equipment manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.