OSHA SearchOSHA records by employer

Braxton Lumber Company, Inc: OSHA inspections and violations

Heaters, West Virginia · Sawmills · NAICS 321113

9inspections
53citation items
$13,571current penalties
Nov 21, 2023last inspection

Braxton Lumber Company, Inc has 9 OSHA inspections on record in West Virginia, the first in 1987.

OSHA's last visit started on Nov 21, 2023 as a planned inspection, in Heaters.

Across those inspections OSHA issued 53 citation items: 29 serious and 24 other-than-serious.

OSHA proposed $21,491 in penalties. After settlements and reviews the total is $13,571, down 37%.

Most often, OSHA cited 1910.265, sawmills (10 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Braxton Lumber Company, Inc averages $1,170 over 2 cited inspections in that time.

1 inspection on this page followed a fatal incident.

Braxton Lumber Company, Inc: OSHA citation items per year, 1987 to 2023
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

27employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Braxton Lumber Company, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347118432 OPENED NOV 21, 2023Closed

Planned · No inspection · Safety · 11 employees at the site · Closed Nov 22, 2023

Rt 19 N, Heaters, WV 26627 · Sawmills · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343493052 OPENED SEP 26, 2018Closed

Planned · Partial · Safety · 12 employees at the site · Closed Dec 31, 2018

Rt 19 N, Heaters, WV 26627 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$3,141$2,041Oct 4, 2018Final

Inspection 340792233 OPENED JUL 22, 2015Closed

Planned · Records only · Safety · 19 employees at the site · Closed Aug 26, 2015

Rt 19 N, Heaters, WV 26627 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$400$300Jul 31, 2015Final

Inspection 313371593 OPENED DEC 16, 2009Closed

Planned · Partial · Safety · 22 employees at the site · Closed Apr 5, 2010

Route 19 North, Heaters, WV 26627 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,000$700Mar 9, 2010Closed
Citation 1, item 1b
29 CFR 1910.147(c)(2) · Lockout/tagout
Serious$0$0Mar 9, 2010Closed
Citation 1, item 1c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Mar 9, 2010Closed
Citation 1, item 2 Serious$1,400$980Mar 9, 2010Closed
Citation 1, item 3 Serious$1,000$700Mar 9, 2010Closed
Citation 2, item 1
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Mar 9, 2010Closed

Inspection 309472587 OPENED MAY 11, 2006Closed

Planned · Complete · Safety · 35 employees at the site · Closed May 23, 2006

Route 19, North, Heaters, WV 26627 · Sawmills · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300467438 OPENED MAY 23, 2002Closed

Planned · Partial · Health · 37 employees at the site · Closed Apr 17, 2003

Route 19, North, Heaters, WV 26627 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Serious$525$300Jun 3, 2002Closed
Citation 1, item 2 Serious$525$300Jun 3, 2002Closed
Citation 1, item 3
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$1,225$600Jun 3, 2002Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$525$300Jun 3, 2002Closed
Citation 1, item 5
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$525$300Jun 3, 2002Closed
Citation 1, item 6
29 CFR 1910.242(a) · Hand and power tools
Serious$525$300Jun 3, 2002Closed
Citation 1, item 7
29 CFR 1910.151(c) · First aid and eyewash
Serious$700$300Jun 3, 2002Closed
Citation 1, item 8 Serious$1,225$600Jun 3, 2002Closed

Inspection 101176907 OPENED APR 12, 1993Closed

Planned · Complete · Safety · 29 employees at the site · Closed Dec 1, 1993

Route 19, North, Heaters, WV 26627 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(b)(2)(viia) · Flammable liquids
Serious$1,225$1,000Jun 9, 1993Closed
Citation 1, item 2
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$525$350Jun 9, 1993Closed
Citation 1, item 4
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$700$500Jun 9, 1993Closed
Citation 1, item 5
29 CFR 1910.157(d)(4) · Portable fire extinguishers
Serious$1,225$1,000Jun 9, 1993Closed
Citation 1, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,225$800Jun 9, 1993Closed
Citation 1, item 7
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$700$500Jun 9, 1993Closed
Citation 1, item 8a Serious$525$350Jun 9, 1993Closed
Citation 1, item 8b
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Jun 9, 1993Closed
Citation 1, item 9
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$700$500Jun 9, 1993Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$350$0Jun 9, 1993Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jun 9, 1993Closed
Citation 2, item 3
29 CFR 1910.24(b) · Fixed industrial stairs
Other-than-serious$0$0Jun 9, 1993Closed
Citation 2, item 4
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jun 9, 1993Closed
Citation 2, item 5
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Jun 9, 1993Closed
Citation 2, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 9, 1993Closed

Inspection 763813 OPENED SEP 15, 1987Closed

Follow-up · Partial · Safety · 14 employees at the site · Closed Sep 22, 1987

R.f.d. 1, Box 107, Sutton, WV 26601 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

1 older inspection

Inspection 619437 OPENED MAR 4, 1987Closed

Accident · Complete · Safety · 13 employees at the site · Closed Sep 23, 1987

R.f.d. 1, Box 107, Sutton, WV 26601 · OSHA's record · Phone and website on Google Maps

Incident on Mar 2, 1987 (fatal): Employee killed when head caught between log and carriage

Employee #1, a barker operator at a sawmill, was trying to dislodge a 39-in. log from the log deck. He slipped from the cant log on which he was standing and fe ll between the log and the log carriage. After he fell, the log moved and his he ad became caught between it and the head block on the log carriage. Employee #1 suffered a fractured skull and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$100$100May 12, 1987Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$300$150May 12, 1987Closed
Citation 1, item 3 Serious$300$150May 12, 1987Closed
Citation 1, item 4 Serious$300$150May 12, 1987Closed
Citation 1, item 5 Serious$300$150May 12, 1987Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$300$150May 12, 1987Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 2
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 3
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 4
29 CFR 1910.37(a) · Exit routes
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 5
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 6
29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 7
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 8
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 9
29 CFR 1910.252(d)(2)(xv) · Welding fire safety
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 10 Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 11 Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 12 Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 13
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 14
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 15
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0May 12, 1987Closed
Citation 2, item 16
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0May 12, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(1)

(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(b)(2)(viia)

(vi) Vent piping for aboveground tanks. (a) Vent piping shall be constructed in accordance with paragraph (c) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.265 · Sawmills

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other sawmills employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.